Thermal-Magnetic Circuit Breakers 3600/3900 www.e-t-a.de2444
Description
Ordering information
Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Designed for plug-in mounting with E-T-A sockets 17-P10-Si, 23-P10-Si, 63-P10-Si; or panel mounting using E-T-A clips. Featuring an unprotected shunt tap terminal and optional auxiliary contacts. Type 3900 offers lower internal resistance values and is fitted as standard with auxiliary contacts and an intermediate reset position in which all contacts are isolated. Approved to CBE standard EN 60934 (IEC 60934). Process control systems, instrumentation, communications systems, rail vehicles. 3600 3900 standard type low-resistance type For further details please see: http://www.e-t-a.de/ti_e Voltage rating AC 240 V, 50/60 Hz; DC 65 V (UL: AC 250 V; DC 65 V) Current rating range 3600: 0.05...16 A 3900: 0.05...10 A Auxiliary circuit 1 A, AC 240 V / DC 65 V min. 10 V/10 mA Typical life 5,000 operations at 1 x IN, inductive 5,000 operations at 2 x IN, resistive Insulation co-ordination rated impulse pollution (IEC 60664 and 60664 A) withstand voltage degree 2.5 kV 2 reinforced insulation in operating area Dielectric strength (IEC 60664 and 60664A) test voltage operating area AC 3,000 V main/aux. circuit AC 1,500 V aux. circuit 4-5/6-7 AC 840 V Insulation resistance >100 MΩ (DC 500 V) Interrupting capacity Icn 3600 3900 self-limiting Interrupting capacity IN UN (UL 1077) 0.05...16 A AC 250 V 1,000 A type 3600: 0.05...16 A DC 80 V 1,000 A Degree of protection operating area IP40 (IEC 60529/DIN 40050) terminal area IP00 Vibration 5 g (57-500 Hz), ± 0.38 mm (10-57 Hz) to IEC 60068-2-6, test Fc 10 frequency cycles/axis Shock 25 g (11 ms) to IEC 60068-2-27, test Ea Corrosion 96 hours at 5 % salt mist to IEC 60068-2-11, test Ka Humidity 240 hours at 95 % RH to IEC 60068-2-78, test Cab Mass approx. 45 g Type No. 3600 standard version with shunt tap terminal -3 3900 low-resistance version Terminal design P10 blade terminals 6.3-0.8 (QC .250) Auxiliary contacts (3900: intermediate position as standard) Si with blade terminals 6.3-08,one each NO/NC, Current ratings 3600 - P10 - Si - 10 A ordering example The exact part number required can be built up from the table of choices shown above. Ordering references for optional features should be omitted if not required. Please be informed that we have minimum ordering quantities to be observed. Standard current ratings and typical internal resistance values Current ratings (A) Internal resistance (Ω) Current ratings (A) Internal resistance (Ω) 3600 3900 3600 3900 0.05 447 211 3 0.19 0.054 0.1 131 48 4 0.090 0.035 0.2 40 12.4 5 0.061 0.025 0.8 2.5 0.76 12 ≤ 0.02 1 1.67 0.49 14 ≤ 0.02 1.5 0.61 0.21 15 ≤ 0.02 2 0.38 0.101 16 ≤ 0.02 2.5 0.24 0.078 Preferred types Standard current ratings (A) 0.5 1 2 4 8 10 16 3600-P10-Si- x x x x x x x 3900-P10-Si- x x x x Preferred types
Thermal-Magnetic Circuit Breakers 3600/3900 www.e-t-a.de 2444 Dimensions Internal connection diagrams 14 63 75 2 202 12.5 operating area (reinforced insulation) mounting area .787.079 1.50 .492 ø11.5 ø6.5 ø8.5 6.8 6 x 6.8 = 40.8 5 ON
11 OFF
DIN 46244-A6.3-0.8 (QC .250) 8.5 2013 11.5 current rating in A 14 63 75 2 .157 .079 .256 .453 .335 .433 .197 2.01.394 .268 6 x .268 = 1.61 .748 .787 1.69 .512 .335 1.97 .453 -P10-Si 3 (from IN=8 A) 3 (from IN=8 A) line 1 line 1 I > I > with shunt terminal (standard) and auxiliary contacts (-Si) only 3600 12 3 Terminal design -P10 Installation drawing Typical time/current characteristics +60 °C +140 °F +23 °C +73.4 °F -30 °C -22 °F … times rated current 12 46 81 02 04 0 … times rated current 10000 1000 100 0.1 0.01 0.001 60 80100 Trip time in seconds 12 46 81 02 04 0 10000 1000 100 0.1 0.01 0.001 60 80100 Trip time in seconds Trip time in seconds 12 46 81 02 04 0 … times rated current 10000 1000 100 0.1 0.01 0.001 60 80100 3900 0.05…10 A DC 2)3600 8…16 A AC 1)3600 0.05…7 A AC 1) 1) Magnetic tripping currents are increased by 20 % on DC supplies. 2) Magnetic tripping currents are decreased by 20 % on AC supplies. This is a metric design and millimeter dimensions take precedence ( mm ) inch The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section Technical information. Ambient temp. °F -22 -30 -20 +14 -10 +32 +73.4 +23 +104 +40 +122 +50 +140 +60
Thermal-Magnetic Circuit Breakers 3600/3900 www.e-t-a.de2444 Thermal-Magnetic Circuit Breakers 3600/3900 Accessories blade terminal DIN 46244 part 2 C profile (2xA2.8-0.8) (QC 2x.110) depth 10 mm (.394 in.) adapter X20040901 symmetrical rail EN 50022-35x7.5 polarization recess G-profile EN 50035-G32 8.525.86.5 33.3 1.4 12.5 41.3 45.8 retaining clip 2.8 -P70 2(k) 2(i) 2(k) 2(i) 1.801. .335 .256 1.02 3.15 1.31 .055 .197 .492 .394 .39 .110 depth 10 mm (.394 in.) adapter X20040901 symmetrical rail EN 50022-35x7.5 polarized blade terminal DIN 46244-A6.3-0.8 (QC .250) polarization recess G-profile EN 50035-G32 slot fitting labels from Phoenix, Weidmüller 8.525.86.5 33.3 1.4 12.5 41.3 45.8 retaining clip 6.3 -P10 2(k) 2(i) 2(k) 2(i) 1.801. .335 .256 1.02 3.15 1.31 .055 .19 .492 .394 .394 .248 Sockets 23-P10-Si 63-P10-Si (up to 16 A max. load) Retaining clip Y 300 581 03 to special order. Sockets 17-P10-Si (up to 16 A max. load) 17-P10-Si-20025 mounted with adapter Retaining clip Y 300 581 11 to special order. Sockets 17-P70-Si (up to 16 A max. load) 17-P70-Si-20025 mounted with adapter Retaining clip Y 300 581 11 to special order. 6 x 6.8 = 40.8 6 x .268 = 1.61 retaining clip22.2 max. 30 3.5 6.8 7.4 4.4 57.4 12.5 4.4 7.4 12.5 6.25 12.5 polarized blade terminals DIN 46244-A6.3-0.8 (QC .250) polarized recess .173 .291 2.52 1.97 2.26 .492 .984 .291 .173 .394 .827 .874 .079 .236 max. 1.18 2.52 .492 1.97 2.95 501.97 2.26 57.4 .268 .492 .246 slot fitting labels from Phoenix, Weidmüller EN 50022-35x7,5 EN 50035-G32115 42,5 51 11,5 6 25 25 max. 38 17 plus 2.2 12.1 12.2 1.2 Line 1.1 Line 2.1 slot for fitting labels from Phoenix, Weidmüller, Wieland slot for busbar module right-side terminal block left-side terminal block symmetrical rail G-profile test socket Module 17plus For technical data see section Power Distribution Systems Approvals Authority Standard Voltage ratings Current ratings 3600: VDE IEC/EN 60934 AC 240 V DC 65 V 0.05...16 A 0.05...16 A UL UL 1077 AC 250 V DC 80 V 0.05...16 A 0.05...16 A CSA C22.2 No. 235 AC 250 V DC 80 V 0.05...16 A 0.05...16 A 3900: VDE IEC/EN 60934 AC 240 V DC 65 V 0.05...10 A 0.05...10 A Power-D-Box with sockets pre-wired 19BGT2 2U for 18, 24 or 30 circuits. For technical data see product group Power Distribution Systems.
Thermal-Magnetic Circuit Breakers 3600/3900 www.e-t-a.de 2444 Accessories /one.varAlt01.9 /one.varAlt01 0.5 2 7.5 /one.varAlt012.5 7.3 8 M4 8.5 60.4 /one.varAlt016.5 20 .075 .039 .295.079.020 .079 .335 .287 .3/one.varAlt015 .492 .650 .787 2.38 /one.varAlt01.97 /one.varAlt0100 quick-connect tabs 6.3 (.250) DIN 46247 tinned brass, insulated Connector bus links -P/one.varAlt010 X 2/one.varAlt010 588 02/ 2.5 mm 2 (AWG /one.varAlt014), black up to 20 A max. load X 2/one.varAlt010 588 03/ 2.5 mm2 (AWG /one.varAlt014), red u p to 20 A max. load X 2/one.varAlt010 588 04/ 2.5 mm2 (AWG /one.varAlt014), blue u p to 20 A max. load ~2.76 ~70 5.4 /one.varAlt0125 /one.varAlt017 .669 .2/one.varAlt013 .354 4.92 cylinder head screw washer M4x4 ISO/one.varAlt01207 nickel plated A 4.3 DIN /one.varAlt0125 nickel plated female connector Phoenix terminal AKG 35 max.cross section 35 m m 2 (AWG 2) /one.varAlt010 /one.varAlt012.87 /one.varAlt0154.8 pressure-relief joint thick constriction ) Cu rail, tin-plated .394 .079 .504.276 6.09 Bus b/a.varAlt01r (/one.varAlt010-w/a.varAlt01y) (supplied as a complete package) for socket /one.varAlt017 (for max. /one.varAlt0100 A continuous load ) X 2/one.varAlt01/one.varAlt01 /one.varAlt0157 02 without termin/a.varAlt01 l (more positions available on request) Insul/a.varAlt01te sleeving for bus b/a.varAlt01r Y 303 824 0/one.varAlt01 Mounting clip Y 300 504 02 (2 pcs needed per unit) Cl/a.varAlt01mping spring Y 300 58/one.varAlt01 /one.varAlt01/one.varAlt01 Installation drawing with mounting clips Y 300 504 02 49 +2 ≈ 25 Ø/one.varAlt01 90° ±0,5 55,4 +0,3 0,8 ±0,2 -/one.varAlt01 3/one.varAlt01 +/one.varAlt01 5 -0,55 -0,5 /one.varAlt015 ±/one.varAlt01 This is a metric design and millimeter dimensions take precedence ( mm ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted.