3572-1A-06-P-01 OENINDIA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

FEATURES

l Suitable for various loads l Heavy Duty l Immersion Cleanable Version available APPLICATION l Direction Indicators l Air-Conditioning Systems l Boby Controllers l Head Lamp Control l Ventilation Motors l Security Systems Contact Configuration : 1A/1C 1A Contact Material : Silver Nickel Palladium Copper* / Silver Nickel Contact Rating at 23 C - 12 VDC : 45 / 30 A 12 A

24 VDC : 20 / 10 A

Electrical Life Operations Min. : 2 x 10 5 x 10 7 7 Mechanical Life Operations Min. : 1 x 10 1 x 10 Contact Voltage Drop at 10 A (Min) : 30mV 50mV Maximum Switching Current : 100A 100A@ 12.8 VDC For 3 Sec. TECHNICAL DATA FOR CONTACT SIDE AREAS OF APPLICATION RESISTIVE / INDUCTIVE LOADS *The moving contact (Pdcu) must be connected to positive potential GENERAL DATA FOR COIL SIDE Nominal Coil Power : 1.6W (Approx) Operating Power : 0.9W (Approx) Operate Time : 5 milli Seconds Release Time : 3 milli Seconds At nominal voltage without coil suppression (excluding bounce) 0 0 Ambient Temperature : -40 C to +85 C Maximum Temperature : 155 C Dielectric Strength : 500VRMS Insulation Resistance : 100 MS Min. At 500 VDC, 25 C RH 50 Vibration Resistance without change : 10-200Hz, 20-40g in the switching state>10µS Shock Resistance without change : 30g, 11mS in the switching state>10µS OPERATING CONDITIONS 3572 AUTOMOTIVE POWER RELAY CIRCUIT DIAGRAM INDICATOR LAMP LOADS **Under in troduction COM NO COIL COM NO COIL

1 Form C

1 Form A

l High Temperature winding wire l Special coil resistance & pick-up l Resistor / Diode across coil l For other custom solutions consult factory 3572 - 1A - 12 - X - 01 - XX Product Series Contact Form 1A - 1 Form A 1C - 1 Form C Plating P- Nickel Plated Body E-Copper Plated Body E-lmmersion Cleanable E5-Open 250g Release spring & 1.7mm wide contact Terminal Nominal Coil Voltage (Refer coil data) Nominal Voltage VDC *Pick-up Voltage VDC (Max) *Lower pick-up voltages available on request Drop-out Voltage VDC (Min) Coil Resistance Ohms ± 10% 06 3.3 0.6 19 12 6.8 1.2 90 24 13.9 2.4 362 DRILLING PATTERN 21.5 max 26.5 max 22.5 max 0.3 min 3.5 max 2.5 min SEALED TYPE OPEN TYPE AVAILABLE ON REQUEST * Vent hole to be opened after PCB soldering and cleaning 19.0 max 24.0 max 12.1 3.30 14.25 2.95 2.75 7.15 11.0 2.15

DATA ON VARIOUS TESTS CONDUCTED FOR OPERATING CONDITIONS TEST TEST CONDITION RESULT Relays successfully completed 100000 operations at given load Relay kept at 100 C Thermal cycling Shock Voltage Dropping Impact No change in operating parameters of the relay. Corrosion Resistance No damage to relay parts Jump Start Withstood successfully Coil Voltage : 14 VDC Load given : 30 A @ 12 VDC Duration : 5 Sec. On, 5 Sec. OFF No. of operation : 50000 The above test repeated at - 30 C for 50000 operations Relay subjected to :- 0 0 -30 C to + 100 C in 2 Hrs. with coil ON +100 C for 2 Hrs. with coil ON 0 0 +100 C to - 30 C in 2 Hrs. with 1 Hrs. Coil ON & 1 Hrs. Coil OFF -30 C for two Hrs. with Coil ON No. of Cycles : 3 Relay is subjected to :- Max. Voltage : 100VDC Shock Wave : Exponential Damping vibration Time : 500 micro Sec. Period : 30 Sec. Test Time : 10 Hrs. Relays dropped from a height of 1 Meter to a concrete floor

24 VDC for 1 minute conducting nominal current

Water Resistance test IP 67 (For Sealed Version) *Typical values for relays with 12 VDC coil. For higher severity please consult factory Continuous Energisation test at Extreme temperature Conditions All operating parameters within the specifications after test After the test, all operating parameters of the relay are within specification. 5% Sodium Chloride solution applied to relay for 48 Hrs.