True-rms 2000 A Clamp Meters High current and a large jaw, make these clamps well suited for industrial and utility applications Confidently take reliable readings with the true-rms, Fluke 355/353 Clamp Meters; the tools of choice for high-current measurements up to 2000 A. The extra-wide jaw easily clamps around large conductors typically found in high- current applications. The rugged design and CAT IV 600 V, CAT III

1000 V ratings, add an extra ele-

ment of protection when taking high-powered measurements. Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this the most versatile tool for utilities, electrical contractors, and industrial service technicians.

  • Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms,

1400 A ac, and 2000 A dc

  • The large 58 mm (2.3 in) jaw capacity is suitable for large, or multiple conductors
  • CAT IV 600 V, CAT III 1000 V rating for added user protection
  • In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
  • High voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc allows users to perform multiple tests with only one tool (355 only)
  • Resistance to 400 kW coupled with a continuity beeper, provide the convenience of a multimeter (355 only)
  • Accurately measure frequency up to 1 kHz for optimum troubleshooting
  • Quickly analyze readings using the MIN, MAX, and AVG functions
  • A large backlit display allows for easy visibility in low-lit areas
  • Use the display hold feature to capture readings even when the display cannot be viewed
  • Use the low-pass filter to smooth out noisy loads and stabilize readings N10140

2 Fluke Corporation Fluke 355/353 True-rms 2000 A Clamp Meters

Current measurement dc and ac 10 Hz to 100 Hz Range Resolution Accuracy, A Trigger Level for Inrush Trigger Level for Hz Filter OFF Trigger Level for Hz Filter ON 40 A 10 mA 1.5 % rdg + 15 digits 0.50 A 2.50 A 0.50 A 400 A 100 mA 1.5 % rdg + 5 digits 5.0 A 2.5 A 2.5 A 2000 A; 1400 ac rms 1 A 1.5 % rdg + 5 digits 5 A 8 A 8 A Crest Factor (50/60 Hz) Range Crest Factor* 40 A 2 @ 33 A, 2.4 @ 27 A 400 A 2 @ 330 A, 2.4 @ 270 A 2000 A; 1400 ac rms 2 @ 1000 A, 2.4 @ 833 A *Add 2 % to error spec for CF > 2 Current measurement ac 100.1 Hz to 1 kHz Range Resolution Accuracy > 10 A Trigger Level for Inrush Trigger Level for Hz Filter OFF Trigger Level for Hz Filter ON 40 A 10 mA 3.5 % rdg + 15 digits 0.50 A 2.50 A 0.50 A 400 A 100 mA 3.5 % rdg + 5 digits 5.0 A 2.5 A 2.5 A 2000 A; 1400 ac rms 1 A 3.5 % rdg + 5 digits 5 A 8 A 8 A Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz 600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively. Range Resolution Accuracy Trigger Level for Hz Filter OFF Trigger Level for Hz Filter ON 4 V 1 mV 1 % rdg + 10 digits 0.050 V 0.050 V 40 V 10 mV 1 % rdg + 5 digits 0.25 V 0.25 V

400 V 100 mV 1 % rdg + 5 digits 6 V 6 V

600 V ac rms 1 V 1 % rdg + 5 digits 6 V 6 V

1000 V dc 1 V 1 % rdg + 5 digits N/A N/A

Voltage measurement (355 only) ac 100.1 Hz to 1 kHz 600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively. Range Resolution Accuracy Trigger Level for Hz Filter OFF Trigger Level for Hz Filter ON 4 V 1 mV 3 % rdg + 10 digits 0.050 V 0.050 V 40 V 10 mV 3 % rdg + 5 digits 0.25 V 0.25 V

400 V 100 mV 3 % rdg + 5 digits 6 V 6 V

600 V ac rms 1 V 3 % rdg + 5 digits 6 V 6 V

Ohms measurement (355 only) Range Resolution Accuracy 400 W 0.1 W 1.5 % + 5 digits 4 kW 1 W 1.5 % + 5 digits 40 kW 10 W 1.5 % + 5 digits 400 kW 100 W 1.5 % + 5 digits

3 Fluke Corporation Fluke 355/353 True-rms 2000 A Clamp Meters

PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800) 36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com ©2007 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 9/2007 3094045 D-EN-N Rev A Fluke. Keeping your world up and running.® Ordering information: Fluke-353 AC/DC True-rms Clamp Meter, 2000 A, Amps only Includes: C43 Soft Carrying Case, 6 AA batteries, and users manual Fluke-355 AC/DC True-rms Clamp Meter, 2000 A Includes: C43 Soft Carrying Case, 6 AA batteries, TL224 1.5 m Silicone Rubber Test Leads, TP2 Test Probes, AC285 Alligator Clips, and users manual Continuity beeper (355 only) On at ≤ 30 W Off at ≥ 100 W Frequency measurement Measurement range 5.0 Hz to 1 kHz Resolution 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) Accuracy – 5.0 Hz to 100 Hz 0.2 % + 2 counts Accuracy – 100.1 Hz to 1 kHz 0.5 % + 5 counts Trigger level Refer to current and voltage tables General specifications Batteries Six 1.5 V AA NEDA 15 A or IEC LR6 Battery life (with typical usage, backlight off) 100 hours Test leads Rated to 1000 V Weight .814 kg (1.8 lb) Jaw size 58 mm (2.28 in) Dimensions (LxWxD) 300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in) Safety rating IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III Environmental specifications Operating temperature 32 °F to + 122 °F (0 °C to +50 °C) Storage temperature -4 °F to 140 °F (-20 °C to +60 °C) Operating humidity 0 to 95 % (non-condensing) Operating altitude 2000 m Storage altitude 10,000 m IP rating 42 (indoor use only) Drop test requirements 1 m EMI, RFI, EMC FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN 61326:1997 3V/m, performance criteria B, EN61325 Temperature coefficients Current: 0.1 % of reading per °C outside 22 °C to 24 °C Voltage: 0.1 % of reading per °C outside 22 °C to 24 °C Fluke-353Fluke-355