350INV60-120-240-9G BEL | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 10

Technical content

The Bel Power Solutions 350INV60 -120-240-9G is a high -efficient DC/AC inverter that converts high -voltage DC power into split phase AC power 120/240 VAC required to drive AC accessory loads directly from the High Voltage DC Drive or Battery Bus. Liquid coo led DC/AC inverter operates at input voltages from 240 to 430 VDC and power range up to 6000 W. The DC/AC inverter utilizes CAN communication to the vehicle controller which allows selection of operational modes and frequency selection. The DC/AC inverter is built in a sealed aluminum enclosure, ready to be mounted to the vehicle chassis and is a commercial -off the-shelf solution for electric vehicle manufacturers and developers.

  • 92 % typical efficiency
  • Input voltage range: 240 – 430 VDC
  • Power rating of 1 module 6 kW, possible parallel synchronized operation up to 6 modules with total power up to 32 or 36 kW
  • Full galvanic insulation between input and output
  • CAN bus serial interface
  • Over temperature, output overvoltage and overcurrent protection
  • Protection degree IP65 and IP67
  • Liquid cooled
  • Vibration immunity meets military level
  • Three phase function: outputs of 3 modules can create 3 phase system 3 x 400 VAC
  • E-MARK E13*10R00-10R05*13865
  • Hybrid and electric vehicles
  • Medium through heavy duty, on and off highway vehicles

tech.support@psbel.com MODEL DESCRIPTION 350INV60-120-240-9G 350INV60-CON-KIT-8G Kit that includes mating input connector with assembled 3 m of HV DC cable, output and signal connector with terminal pins 350INV60-CON-KIT-9G Kit that includes input, output and signal connectors with terminal pins PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT Input Voltage 240 350 430 VDC Max. Input Current at nominal Power 6000 W Vin = 240 Vmean 28 34 ADC Max. Input Current at peak Power 8000 W Vin = 240 Vmean 37 ADC Typical Efficiency Maximum @ Vin = 350 VDC, Pout = 4 kW, T_coolant = 40°C 92 % Internal Power Loss @ Vin = 350 VDC, Pout = 6 kW, T_coolant = 40°C 430 W @ Vin = 350 VDC, Pout = 0 kW, T_coolant = 40°C 110 W Input Line Interruption Inverter shutdown 240 VDC Input Capacitance 100 µF Insulation Input-to-Chassis: Basic 3000 VDC Input-to-Output: Reinforced 3000 VDC Insulation Resistance Input to Chassis (ground) 10 MΩ Input to Output 10 MΩ Input Current Waveform remaining amplitude part of 50 / 60 Hz component 10 % PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT Output Voltage L1 to N, L2 to N 120 VAC L1 to L2 240 VAC Phase shift L1 to L2 180 Deg Output Current @ 6kW 25 A Output Power Continuous Output overload, (max. 10 sec.) Overload for motor load spin-up (max 3 sec) kVA Static Regulation L1 = L2 = 120 VAC at load 0 to 25 A -12 + 12 VAC In-factory Output Calibration L1 to L2 = 240 VAC at load 25 A, T_coolant = 30°C 237.75 237.85 VAC Frequency 50 / 60 Hz Periodic and Random Deviation @ 120 VAC / Nominal load - Differential Mode 20 MHz of Vo_max - Differential Mode 20 MHz Vp-p Load Crest Factor Vin = 240 – 430 Vmean, So1 = So2 = 3 kVA, Ipk1 = Ipk2 = 70 A, T_ambient = 85°C, T_coolant = 70°C 2.5 Total Harmonic Distortion Vin = 240 – 430 Vmean, So1 = So2 = (0.01 kVA, 1 kVA, 3 kVA), cos(fi) = (0.5, 1), T_ambient = 25°C, T_coolant = 50°C 0.1 – 1 kVA linear load 1 – 3 kVA linear load Turn-On Delay After application of DC input or cycling enable signal 5000 ms Load Power Factor The output voltage of the inverter kept within the limits. 0.3 1

+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2021 Bel Power Solutions & Protection BCD.00331_AB3 PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT Output Over-Current Protection shut-down time Vin = 240 - 430 Vmean, T_ambient = 85°C, T_coolant = 70°C, Io1 = Io2 = step from 25 Arms to 27.5 Arms Io1 = Io2 = step from 25 Arms to 33 Arms Io1 = Io2 = step from 25 Arms to >33 Arms Sec Short Circuit Survival shut-down time Vin = 350 Vmean, T_ambient = 85°C, T_coolant = 70°C, Io1 = Io2 = from 25 Arms/cos(Fi) = 1 to short cut 60 ms Output Over-Voltage Protection Latch type 200 210 Vpk Output Under-Voltage Protection UV duration 60 ms 95 100 Vrms Over-Temperature Protection Converter shutdown at T_coolant higher than 70 °C Input Fuse Protection DC Input: Single on positive pole 50 A Input Low Line Protection Turn ON threshold Turn OFF threshold 250 235 255 240 260

245 VDC

Input Overvoltage protection Recovery: Vin re-cycling or ENABLE 435 450 VDC PARAMETER DESCRIPTION / CONDITION CAN BUS SAE J1939 Interface 250 kBit/s ENABLE Inverter turned ON signal is pulled-up 100 k Ohm to 5 V internally Inverter turned OFF pulled down to 0.6V or 100 Ohm to signal GND FREQ_SELECT Output frequency selected to 60 Hz signal is pulled up 100k Ohm to 5 V internally Output frequency selected to 50 Hz signal is pulled down to 0.6 V or 100 Ohm or less to signal GND SYNC Operation of multiple inverter modules in redundant parallel mode. SYNC signals of individual modules have to be connected together and twisted with signal ground HVIL function Internal short is provided on HVIL pins. PARAMETER DESCRIPTION / CONDITION Output current readback accuracy Under all conditions for currents below 4.0 A rms read back is not working, i.e. read back value is 0 A For current higher than 4.0 A this readback is valid: In case of crest factor 1 : + / - 2.0 Arms In case of crest factor higher than 2.5 : + / - 3.0 Arms Input voltage readback accuracy +/ - 2.0 VDC Output voltage readback accuracy + / - 2.0 Vrms PARAMETER DESCRIPTION / CONDITION CRITERION Insulation Basic Reinforced Input-to-Protective Earth Input-to-Output Radiated Emission CISPR22, EN55022 Class A Conducted Emission CISPR22, EN55022 Class A Electrostatic Discharge IEC 61000-4-2 (10 V/m) Performance Criterion B Radiated Electromagnetic Field IEC 61000-4-3, SAE J1113/21 Performance Criterion B Electrical Fast Transient (EFT) /Burst IEC 61000-4-4, ISO 7637-2; Level 2 (+/-2 kV, 2.5 kHz) Performance Criterion B RF Conducted Immunity Level 3 (10V, 0.15…80 MHz, AM 80%, 1 KHz) Performance Criterion A RF Disturbances Immunity SAE J1113-41 Class A

tech.support@psbel.com PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT Altitude Operating: 62 kPa absolute pressure Non-Operating:18.6 kPa absolute pressure 3600 12200 m Operating Temperature Liquid cooled: Tcoolant with no derating Tamb @ full load, with no power derating -40 -40 +70 +85 Storage Temperature -40 +95 °C Humidity SAE J1455 JAN 2011 Shock SAE J1455 Vibration SAE J1455, MIL-STD-202G PARAMETER DESCRIPTION / CONDITION MANUFACTURER MPN Input Connector High voltage connecter with HVIL function Delphi HV280 13737767 Output Connector High voltage unshielded connector Delphi 13879038 CAN BUS and Signal Interface Panel mounted Molex MX150 47725-1310 PARAMETER DESCRIPTION / CONDITION MPN DC Input Connector Housing Delphi (1pc) Female terminal (2pcs) 13737728 13572764 HVIL housing (1pc), Female terminal (2pcs) 13738743 13543114 Sealing (1pc) 13756257 AC Output Connector Housing Delphi (1pc) Power terminal (4pcs), Signal terminal (2pcs, not used for contact) 13879046 13783301 13711549 CAN BUS and Signal Interface Housing Molex (1pcs) Female terminal (12pcs, 11pcs used for contact) 33472-1206 0330122002 Note: Not all cavities are used for electrical function in signal and output connector. In order to maintain IP67 also non us ed cavities in mating connector must be assembled by dummy wires to get gasket into tightness. DC Input Connector AC Output Connector Signal Connector CAN L ADR 0 ADR 1 RESERVED CAN H 1 6 7 12 SYNC CHAIN SUPPLY CHAIN IN CHAIN OUT SIGNAL GND ENABLE FREQ SELECT V OUT N V OUT N V OUT L1 V OUT L2 HVIL V IN (-) V IN (+)

+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2021 Bel Power Solutions & Protection BCD.00331_AB3 PIN DESCRIPTION FUNCTION

1 ENABLE ENABLE

2 FREQ_SELECT Frequency select

3 SYNC Multi inverter synchronization

4 CHAIN_SUPPLY Chain protection supply

5 CAN_H CAN BUS H

6 CAN_L CAN BUS L

7 SIGNAL_GND Signal return

8 ADR_0 Addressing pin

9 ADR_1 Addressing pin

10 CHAIN_IN Chain protection input

11 CHAIN_OUT Chain protection output

12 Reserved Reserved

Signal Connector Pin Description Purpose of running multiple modules in parallel is to get higher power. The maximum number of parallel modules is 6, see wiring diagram below. Number of modules Max. Power 1 [kVA] Full coolant temp. range Max. Power 2 [kVA] Reduced coolant temp range to 50°C 2 11.2 12 3 16.8 18 4 22.4 24 5 28.0 30 6 33.6 36 During parallel operation load current is shared evenly between modules. However because of production tolerance on the output voltage calibration and passive current sharing between modules (droop sharing) there may be a deviation of load current - up to 6% difference module to module is possible vs. the average value. The result of this deviation may cause some modules to delive r more current than others. In the Table above, in the centre column (Max. power 1), is the available power when none of the paralleled modules override their nominal current of 25 A. The right column specifies condition for n modules - n * 6 kVA. In the case of Max. Power 2, some of the modules may be operating over their nominal power. Functioning above the maximum power is however acceptable since the overcurrent protection only activates at an output current of ~27.5 A, however this is only possible when operating at a lower coolant temperature range, so that the over-temperature protection doesn’t trip off the overloaded module. Modules connected in a 3 phase configuration, per the diagram below are able to produce a 3 x 400 VAC output. To achieve the 240 VAC, each modules L1 is connected to L2. The slaves function at 120° and 240° out of phase from the master by setting up the addressing per the table below. Note: Eac h of the address pins are digital and have internal pull up impedances, therefore a non-connected pin will result in a logic high. ADR_0 (PIN8) ADR_1 (PIN9) FUNCTION 1 1 Master 0 1 Slave 120 Deg 1 0 Slave 240 Deg 0 0 Reserved

tech.support@psbel.com MULTI-UNIT CAN ADDRESSING After input power is connected parallel modules (or units connected in a three phase configuration, here after called “paired” units) automatically allocate their addresses on the CAN line. The design allows up to 6 paired modules, addresses are always chosen from the range of B4 to B9. Every time the input power is re-cycled there may be different addresses allocated to units in comparison to the previous state, but they will be always inside of range of B4 to B9. If the user counts active devices, within this range, you know how many modules are actively connected. In case the CAN line is not required for paired modules, then it does not need to be connected. However in the case CAN is not used the sync BUS and chain circuit still need to be co connected. ENABLE CONTROL Output enable control works either through the hardware enable pin or by sending CAN message “nv_b_cmd_Enable”. In parallel mode, hardware enable pins are required to be wired together, this ensures the same level is sent to all modules. The requirement CAN enable message is sent out to all active units. With the exception of the above, both enable controls are equivalent. By re- cycling the enable control (disable then re-enable) will clear an output latch condition that might have occurred because of a protection feature e.g.: output over current, over temperature, etc. PAIRED MODE SYNC Modules use the “sync” signal to synchronize their outputs. This happens automatically and there is no user intervention required. After start up one of the paired units automatically establishes itself as the master, all other units in the paired configuration will default to slave operation. Slaves synchronize their outputs according to the reference waveform from master. READ BACK OF INPUT / OUTPUT VALUES In paired mode each module provides its own values. However in paired mode when input and/or output voltages are tied together there could be a read back inaccuracy of up to typical ± 2V. Regarding output current, each module will provide its own value. To get the total output current the user must summarize read backs from all active modules. PAIRED MODE PROTECTION FUNCTIONS In paired mode, the signal connector wiring is continuously monitored. This monitoring serves to protect modules against losi ng synchronization signal during service and is established via a chain circuit starting from the first module and ending with the last. The user needs to establish the chain circuit in the external wiring harness according to diagrams below. In case the chain line is broken all units in the chain will shut down and provide active warning bit on CAN Bit 29 – Inv_b_flt_SyncError. This may happen for example when signal connector of any unit is unplugged during service. There is no redundancy provided for paired modules. This means in case a functional failure would occur in any of the paired modules, all modules would shut down. This is a requirement to protect output stages of modules against permanent damage. PAIRED MODE CHASSIS GROUNDING During parallel operation it is required that the chassis of all paired modules are galvanic tied together and grounded to PE.

+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2021 Bel Power Solutions & Protection BCD.00331_AB3 Wiring setup for parallel operation 350INV60-120-240-9G Wiring setup for single operation 350INV60-120-240-9G

tech.support@psbel.com Wiring setup for 3-phase operation 350INV60-120-240-9G PARAMETER Dimensions (W x H x D) 374 x 163 x 384 mm Weight 20 kg Enclosure IP65 and IP67 Maximum allowed pressure of cooling liquid 20 PSI (1.4bar) Recommended Coolant Medium/Mixture 50/50 Propylene or Ethylene Glycol/Water Recommended Coolant Flow 0.0208 to 0.0505 l/s (0.33 to 0.8 GPM) Inlet/Outlet Coolant Connection Hose Adapter, Threaded 1-14 UNF, Stainless Steel

+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2021 Bel Power Solutions & Protection BCD.00331_AB3 DELPHI P/N 13737767 DELPHI P/N 13879038 MOLEX P/N 47725-2010 GORE VENT P/N PMF100444 M8x16mm TORQUE MAX. 21Nm MAX. LENGTH OF SCREW 16mm HOSE ADAPTER, THREADED 1-14 UNF STAINLESS STEEL TORQUE MAX. 94,5Nm 320 ±1 173 ±1 Mechanical Drawing – Front View

tech.support@psbel.com 362 ±1.5 362 ±1.5 HOT SURFACE LABEL HIGH VOLTAGE LABEL PRODUCT LABEL 374 (384) 320 ±1 122 347 362 159 ±1.5 162.1 Bottom View Side View 100.9 ±0.5 257.1 ±0.5 348 ±1 41.5 ±0.5 41.5279 R 4. 25 164.5 ±0.5 193.5 ±0.5 Top View NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.