Thermal-Magnetic Circuit Breaker 3500 www.e-t-a.de1948
Description
Ordering information
Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring a flange for panel mounting and optional auxiliary contacts. Approved to CBE standard EN 60934 (IEC 60934). Control systems, instrumentation, medical equipment, machine tools, robotics, communications systems. 3500 Type No. 3500 standard version Terminal design P10 blade terminals 6.3-0.8 (QC .250), tinned Auxiliary contacts (optional) Si auxiliary contacts, silver plated terminals one each N/O and N/C Current ratings 0.05...16 A 3500 - P10 - Si - 10 A ordering example The exact part number required can be built up from the table of choices shown above. Ordering references for optional features should be omitted if not required. Please be informed that we have minimum ordering quantities to be observed. For further details please see: http://www.e-t-a.de/ti_e Voltage rating AC 240 V, 50/60 Hz; DC 65 V (UL: AC 250 V; DC 80 V) Current rating range 0.05...16 A Auxiliary circuit 1 A, AC 240 V / DC 65 V Typical life 5,000 operations at 1 x IN, inductive 5,000 operations at 2 x IN, resistive Insulation co-ordination rated impulse pollution (IEC 60664 and 60664 A) withstand voltage degree 2.5 kV 2 reinforced insulation in operating area Dielectric strength (IEC 60664 and 60664A) test voltage operating area AC 3,000 V main/aux. circuit AC 1,500 V aux. circuit 4-5/6-7 AC 840 V Insulation resistance > 100 MΩ (DC 500 V) 1...2 A 200 A 2.5...16 A 400 A Interrupting capacity IN UN (UL 1077) 0.05...16 A AC 250 V 1,000 A 0.05...16 A DC 80 V 1,000 A Degree of protection operating area IP40 (IEC 60529/DIN 40050) terminal area IP00 Vibration 5 g (57-500 Hz), ± 0.38 mm (10-57 Hz) to IEC 60068-2-6, test Fc 10 frequency cycles/axis Shock 25 g (11 ms) to IEC 60068-2-27, test Ea Corrosion 96 hours at 5 % salt mist to IEC 60068-2-11, test Ka Humidity 240 hours at 95 % RH to IEC 60068-2-78, test Cab Mass approx. 40 g Standard current ratings and typical internal resistance values Approvals Current rating (A) Internal resistance (Ω) Current rating (A) Internal resistance (Ω) 0.05 447 3 0.19 0.1 131 4 0.090 0.2 40 5 0.061 0.3 19.3 6 0.041 0.4 10.4 7 0.034 0.5 7.1 8 ≤ 0.02 0.6 4.3 10 ≤ 0.02 0.8 2.5 12 ≤ 0.02 1 1.67 14 ≤ 0.02 1.5 0.61 15 ≤ 0.02 2 0.38 16 ≤ 0.02 2.5 0.24 Authority Standard Rated voltage Current ratings VDE IEC/EN 60934 AC 240 V DC 65 V 0.05...16 A 0.05...16 A UL UL 1077 C22.2 No 235 AC 250 V DC 80 V 0.05...16 A 0.05...16 A CSA C22.2 No 235 AC 250 V DC 80 V 0.05...16 A 0.05...16 A
Thermal-Magnetic Circuit Breaker 3500 www.e-t-a.de 1948 Ambient temperature °F -22 -30 -20 +14 -10 +32 +73.4 +23 +104 +40 +122 +50 +140 +60 The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also mounting area operating area (reinforced insulation) max. 2.5 .315 .276 .039 max .098 Dimensions Internal connection diagrams blade terminals DIN 46244-A6.3-0.8 (QC .250) ø8.5 4 6.3 15.5 9.5 4.5 2.5 OFF ON 46.511 42 11.5 4.5 current rating in A ø3.5 .335 .157 .248 1.83.433 1.65 .098 .177 .374 .610 .177 .453 .787 1.14 1.97 2.28 .138 .433 Version -P10 I > line 1 I > with auxiliary contacts (-Si) line 1 -P10-Si .276 14 26 Terminal design Installation drawing Typical time/current characteristics +60 °C +140 °F +23 °C +73.4 °F -30 °C -22 °F … times rated current 12 46 81 02 04 0 … times rated current 10000 1000 100 0.1 0.01 0.001 60 80100 Trip time in seconds 12 46 81 02 04 0 10000 1000 100 0.1 0.01 0.001 60 80100 Trip time in seconds 3500 8…16 AA C 1) 3500 0.05…7 AA C 1) 1) Magnetic tripping currents are increased by 20 % on DC supplies. This is a metric design and millimeter dimensions take precedence ( mm ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted.