Features
- 3-pole contactors.
- Convenient “universal” mounting plate.
- Optional interlock/auxiliary switches available. Coil Data Nominal Coil Voltage 24 120 208/240 277 480 Maximum Pickup Volts 18 88 177 220 384 Drop-Out Volts Range 6 -15 20 - 70 40 - 110 65-185 150 - 270 Nominal Inrush VA @ 50 Hz 285 285 285 285 285 Nominal Inrush VA @ 60 Hz 240 240 240 240 240 Nominal Sealed VA @ 50 Hz 42 42 42 42 42 Nominal Sealed VA @ 60 Hz 27 27 27 27 27 Nominal DC Resistance - Ohms .63 15.6 63.5 84 255 Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Full Number Line Locked Resistive Tungsten/ Maximum Horsepower Load of Voltage Rotor Amps Ballast Voltage Single Three Amps Poles Amps Amps Phase Phase 110/120 5 - 75 3 240 450 93 – 200/208 10 20 480 375 93 63 240/277 15 25 600 300 93 – 480 - 40 600 - 25 110/120 7.5 - 90 3 240 540 120 – 200/208 15 25 480 450 120 63 240/277 20 30 600 360 120 – 480 - 50 600 - 50 Contact Data @ 25°C Arrangements: 3 Form X (3PST -NO-DM). Maximum Ratings: See Contact Ratings Table. Material: Silver Cadmium Oxide. Coil Data @ 25°C Voltage: 24 - 480 VAC, 50/60 Hz. See Coil Data Table below. Insulation Class: UL Class B (130°C). Duty Cycle: Continuous. Environmental Data T emperature Range:Storage and Operating: -40°C – +65°C. Flammability: UL 94-HB housing. Mechanical Data Contact T ermination: T ype:Box Lug with dual 0.250” (6.35 mm) quick connects. Wire Size: 14-1/0 Cu/Al AWG Tightening T orque:50 in.-lbs. Coil T ermination:0.250” quick connect and a #6-32 screw. Arc Cover: Standard. Weight: 64 oz. (1820 g) approximately Model 96 - 3186 series Definite Purpose Contactor 3-pole, 75-90 FLA AC Coil File E75492 File EN60947-4-1:1991 IEC 947-4-1
reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Catalog 1308242 Issued 3-03 (PDF Rev. 1-06) Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. None at present. Standard part numbers listed below are more likely to be available from stock.
Ordering Information
T ypical Part No. BB 3186 - 30 I 90 999 1. Series: 3186 = 3-pole, 75-90 FLA contactor 2.Packaging: Y = Individual Pack - = Bulk Pack A-ZZZ = Customer specific information (assigned by factory) 3.Pole Configuration: 30 = 3 Form X (3PST -NO-DM) 4.Coil Voltage (50/60 Hz.): I = 24VAC, molded K = 208/240VAC, molded W = 480VAC, molded J = 120VAC, molded M = 277VAC, molded 5.Contact Ratings (Inductive): 75 = 75 FLA 90 = 90 FLA 6.Customer ID Suffix: 999 = Standard Model 000-998 = Factory assigned customer ID 7 . Option Code: Leave Blank = No customer-specific options A - ZZ = Factory assigned customer-specific options. Standard on 75-90 FLA Lug accepts 14-1/0 Cu/Al AWG .406 (10.31) Factory Modifications Field Added Kits Description Contact Config. Kit Catalog Number of NO NC Number Kits Required Single unit interlock 1 0 34300-303 1 configurations listed. 0 1 34300-331 1 Maximum of two. Must 1 1 34300-332 1 be same polarity. 2 0 34300-303 2 See footnote (1) for ratings. 0 2 34300-331 2 2 2 34300-332 2 SPDT Circuit 1 1 34300-337 1 See footnote (2) for ratings. 2 2 34300-337 2 SPDT Dry Circuit, 0.1 amp max. 1 1 34300-341 1 Gold Flashed Contacts 2 2 34300-340 1 Various interlock / auxiliary switches are available for the Model 96 contactor. NORMALLY OPEN & CLOSED -332 STYLE Equipped with 0.250” (6.35) Quick Connect Terminals Shown with Optional Auxiliary Switch NORMALLY CLOSED -331 STYLE NORMALLY OPEN -303 STYLE Factory Modifications Field Added Kits Description Contact Config. Kit Catalog Number of NO NC Number Kits Required Single unit interlock 1 0 34300-342 1 configurations listed. 0 1 34300-343 1 Maximum of two. Must 1 1 34300-344 1 be same polarity. (note 1) Equipped with #6-32 Screw Terminals & Saddle Clamps Footnotes: Ratings of Auxiliary Interlocks / Switches (1) Contact Rating Single Circuit NO or NC (2) Contact Rating SPDT (337): and two circuit NO/NC: 10A, 1/3 HP , 125 or 250 VAC 120V 240V 480V 600V 1/2A, 125 VDC; 1/4A, 250 VDC: Break 3.0A 1.5A 0.75A 0.6A 4A 120 VAC on Lamp Load Make 30A 15A 7.5A 6A Continuous 10A 10A 10A 10A SPDT -337 & -341 STYLE W/ #6-32 SCREW & SADDLE CLAMP -344 STYLE 4.062 (103.2) 4.187 (106.3) 4.625 (117 .5) 2.875 (73.02) 5.00 (127 .01) .188 (4.78) 3.75 (95.25) .203 (5.16) 3.75 (95.25) Standard part numbers listed below are more likely to be available from stock. Outline Dimensions T ermination 2.25 (57 .15) 2.50 (63.5) 2.875 (73.02) 2.50 (63.5)