Page <1> V1.022/04/20 3182B, 3183B LSZH / H05Z1Z1-F Unscreened Multicore Flexible Cable Newark.com/multicomp-pro Farnell.com/multicomp-pro Element14.com/multicomp-pro Application: Used as an indoor general wiring cable primarily for installations in public areas. Examples include use on pendant lighting drops or as a general supply lead within hospital or airport projects. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Cable Standards: Made in accordance with the following: BS EN 50525-3-11 (HD21.14), BS EN/IEC 60332-1-2, BS EN/IEC 60332-3-24.C Construction: Conductor : Class 5 flexible copper conductor according to BS EN 60228 (previously BS 6360) Insulation : LSZH (Low Smoke Zero Halogen) Type TI6 according to BS EN 50363 Sheath : LSZH (Low Smoke Zero Halogen) Type TM7 according to BS EN 50363 Characteristics: Voltage Rating (Uo/U) : 300/500V Temperature Rating : -20°C to +60°C Min. Bending Radius : 5 × overall diameter Core Identification : 2 core: Blue & Brown 3 core: Green/Yellow, Blue & Brown Sheath Colour : White & Black Electrical Characteristics: Current Carrying Capacity and Mass Supportable Nominal Cross Sectional Area mm2 Current Carrying Capacity Max. Mass Supportable by Twin Flexible Cord kg Single-Phase AC Amps Three-Phase AC Amps 0.75 6 6 3 1 10 10 5 1.5 16 16 5 2.5 25 20 5

Page <2> V1.022/04/20 3182B, 3183B LSZH / H05Z1Z1-F Unscreened Multicore Flexible Cable Newark.com/multicomp-pro Farnell.com/multicomp-pro Element14.com/multicomp-pro De-Rating Factors: Ambient Temperature +35°C +40°C +45°C +50°C +55°C 60ºC Thermoplastic or Thermosetting Insulated Cords Conductors: Class 5 Flexible Copper Conductors for Single Core and Multi-Core Cables Nominal Cross Sectional Area mm2 Max. Diameter of Wires in Conductor mm Max. Resistance of Conductor at 20°C Plain Wires Ω/km 0.75 0.21 26 1 0.21 19.5 1.5 0.26 13.3 2.5 0.26 7.98 The above table is in accordance with BS EN 60228 (previously BS 6360) Dimensions: Part Number No. of Cores Colour Codes Nominal Cross Sectional Area mm2 Nominal Thickness of Insulation mm Nominal Overall Diameter mm Nominal Weight kg/km PP000916 2 White 0.75 0.6 6.3 57 PP000917 2 Black 0.75 0.6 6.3 57 PP000918 2 White 1 0.6 6.6 65 PP000919 2 Black 1 0.6 6.6 65 PP000920 2 White 1.5 0.7 7.4 84 PP000921 2 Black 1.5 0.7 7.4 84 PP000922 3 White 0.75 0.6 6.7 68 PP000923 3 Black 0.75 0.6 6.7 68 Conductor operating temperature: 60ºC* * The tabulated values above are for 60ºC thermoplastic or thermosetting insulated flexible cords and for other types of flexible cords they are to be multiplied by the following factors: 90ºC thermoplastic or thermoseting insulation : 1.09 Nominal Cross Sectional Area mm2 DC or Single-Phase AC mV/A/m Three-Phase AC mV/A/m 0.75 62 54 1 46 40 1.5 32 27 2.5 19 16 Voltage Drop

Page <3> V1.022/04/20 3182B, 3183B LSZH / H05Z1Z1-F Unscreened Multicore Flexible Cable Newark.com/multicomp-pro Farnell.com/multicomp-pro Element14.com/multicomp-pro Part Number Table Description Sheath Colour Reel Length (m) Part Number 3182B, 3183B LSZH / H05Z1Z1-F Unscreened Multicore Flexible Cable White 100 PP000916 Black PP000917 White PP000918 Black PP000919 White PP000920 Black PP000921 White PP000922 Black PP000923 Black PP000924 Black PP000925 White PP000926 White PP000927 Black PP000928 Part Number No. of Cores Colour Codes Nominal Cross Sectional Area mm2 Nominal Thickness of Insulation mm Nominal Overall Diameter mm Nominal Weight kg/km PP000924 3 Black 1 0.6 7 78 PP000925 3 Black 1.5 0.7 8 107 PP000926 3 White 1.5 0.7 8 107 PP000927 3 White 2.5 0.8 9.9 163 PP000928 3 Black 2.5 0.8 9.9 163 Important Notice : This data sheet and its contents (the “Information”) belong to the members of the AVNET group of companies (the “Group”) or are licensed to it. No licence is granted for the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group’s liability for death or personal injury resulting from its negligence. Multicomp Pro is the registered trademark of Premier Farnell Limited 2019.