© 2011 Fluke Corporation. All rights reserved. Specifications subject to change without notice. All product names are trademarks of their respective companies. Clamp Meter Users Manua l

LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. Fluke Corporation Fluke Europe B.V. P.O. Box 9090 P.O. Box 1186 Everett, WA 98206-9090 5602 BD Eindhoven U.S.A. The Netherlands

i Table of Contents Title Page

The Fluke 317 and 319 are hand-held, battery-operated clamp meters (the Product) that measure:

  • ac and dc current
  • ac and dc voltage
  • resistance
  • continuity
  • frequency The Product ships with:
  • test leads
  • soft case
  • three AAA batteries (installed)
  • 317/319 User Manual How to Contact Fluke To contact Fluke, call one of these telephone numbers:
  • Technical Support USA: 1-800-44-FLUKE (1-800-443-5853)
  • Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853)
  • Canada: 1-800-36-FLUKE (1-800-363-5853)
  • Europe: +31 402-675-200
  • Japan: +81-3-6714-3114
  • Singapore: +65-738-5655
  • Anywhere in the world: +1-425-446-5500

Or, visit Fluke’s website at www.fluke.com . To register your product, visit http://register.fluke.com . To view, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals . Safety Information XWarning To prevent possible electrical shock, fire, or personal injury:

  • Use the Product only as specified, or the protection supplied by the Product can be compromised.
  • Limit operation to the specified measurement category, voltage, or amperage ratings.
  • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
  • Carefully read all instructions.
  • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory.
  • Do not use the Product around explosive gas, vapor, or in damp or wet environments.
  • Use only correct measurement category (CAT), voltage, and amperage rated probes, test leads, and adapters for the measurement.
  • Do not work alone.
  • Do not apply more than the rated voltage, between the terminals or between each terminal and earth ground.
  • Comply with local and national safety codes. Use personal protective equipment (approved rubber gloves, face protection, and flame-resistant clothes) to prevent shock and arc blast injury where hazardous live conductors are exposed.
  • Replace the batteries when the low battery indicator shows to prevent incorrect measurements.
  • Keep fingers behind the finger guards on the probes.
  • Measure a known voltage first to make sure that the Product operates correctly.
  • Do not use and disable the Product if it is damaged.
  • Connect the common test lead before the live test lead and remove the live test lead before the common test lead.
  • Read all safety Information before you use the Product.
  • Remove all probes, test leads, and accessories that are not necessary for the measurement.
  • Before each use, examine the Product. Look for cracks or missing pieces of the clamp housing or output cable insulation. Also look for loose or weakened components. Carefully examine the insulation around the jaws.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation, exposed metal, or if the wear indicator shows. Check test lead continuity.
  • Disconnect power and discharge all high-voltage capacitors before you measure resistance, continuity, capacitance, or a diode junction.
  • Do not hold the Product anywhere above the tactile barrier. See Figure 1.
  • Do not use the current sensor if the wear indicator in the jaw opening is not visible. See Figure 2. For safe operation and maintenance of the product:
  • Remove batteries to prevent battery leakage and damage to the Product if it is not used for an extended period.
  • Be sure that the battery polarity is correct to prevent battery leakage.
  • Repair the Product before use if the battery leaks.
  • Have an approved technician repair the Product.
  • Remove the input signals before you clean the Product.
  • Do not operate the Product with covers removed or the case open. Hazardous voltage exposure is possible.

Table 1. Symbols X Hazardous voltage. Risk of electric shock. waste. Go to Fluke’s website for recycling information.  Conforms to relevant European Union directives. and lighing systems in large buildings.

below their required voltage 2.29 x 1.20 in) (batteries included) IEC 61010-2-032

The accuracy specification is defined as ±(% reading + digits) at 23 °C ± 5 °C. Function Parameter 317 319 (A ac) Range 40.00 A 600.0 A 40.00 A 600.0 A 1000 A Resolution 0.01 A 0.1 A 0.01 A 0.1 A 1 A Accuracy 1.6 % ±6 digit (50-60 Hz) [40 A] 2.5 ±8 digit (60-500 Hz) [40 A] 1.5 % ±5 digit (50-60 Hz) [600 A] 2.5 ±5 digit (60-500 Hz) [600 A] 1.6 % ±6 digit (50-60 Hz) [40 A] 2.5 ±8 digit (60-500 Hz) [40 A] 1.5 % ± 5 digit (50-60 Hz) [600/1000 A] 2.5 ±5 digit (60-500 Hz) [600/1000 A] Crest factor add 2 % into spec for CF >2

3.0 Max @ 500 A

2.5 Max @ 600 A

1.4 Max @ 1000 A

Function Parameter 317 319 (A dc) Range 40.00 A 600.0 A 40.00 A 600.0 A 1000 A Resolution 0.01 A 0.1 A 0.01 A 0.1 A 1 A Accuracy 1.6 % ±6 digit [40 A] 1.5 % ±5 digit [600 A] 1.6 % ±6 digit [40 A] 1.5 % ±5 digit [600/1000 A] (V ac) Range 600.0 V Resolution 0.1 V Accuracy 1.5 % ±5 digit (20-500 Hz) AC response rms (V dc) Range 600.0 V Resolution 0.1 V Accuracy 1 % ±4 digit Ω Range 400.0 Ω 4000 Ω Resolution 0.1 Ω 1 Ω Accuracy 1 % 5.0  ≤30 Ω Inrush Integration Time N/A 100 ms

Function Parameter 317 319 Hz Range N/A 5.0 - 500.0 Hz Accuracy N/A 0.5 % ±5 digit Trigger Level N/A 10 – 100 Hz ≥5 A, 5 – 10 Hz, 100 – 500 Hz ≥10 A The accuracy specifications apply at 23 °C ± 5 °C (73 °F ±41 °F) Below 18 °C and above 28 °C (64 °F and above 82 °F) accuracy degrades at (0.1) times specification per °C. True rms for ac V and ac A accuracy is specified from 5 % to 100 % of range.

One-year calibration cycle flash ROM. Environmental Specifications 90 % RH (50 °F to 86 °F) (10 °C to 30 °C) 75 % RH (86 °F to 104 °F) (30 °C to 40 °C) 45 % RH (104 °F to 122 °F) (40 °C to 50 °C) (Without Condensation) sea level mean sea level 2, 5-500 Hz, 30 minutes per axis floor EMC field ≥0.1 V/m

V 1000 A 40 A 600 A V Hz ACDC AMAXMINAVG 600 V 1000 A

1 ClampMeter

etr111.eps Tactile Barrier

V 1000 A 40 A 600 A A 600 V 1000 A ZE RO INRUSH MINMAX HOLD 319 TRUE RMS CLAMP M ETER CAT600V COM V OFF V 100 40 A 600 A A 600 V 1000 A Hz Hz 3 A

2 Jaw Wear

etr113.eps Jaw Wear Indicator

V 1000 A 40 A 600 A V Hz ZERO V V etr114.eps

V 40 A OFF V 1000 A 40 A 600 A Hz <30 etr116.eps

7 Display Hold

V

8 MIN MAX AVG

2 sec = Exit MIN MAX MIN MAX MIN MAX MIN MAX HOLD OFF V 1000 A 40 A 600 A V Hz ZERO INRUSH MIN MAX HOLD 319 SC OFF V 1000 A 40 A 600 A V Hz etr122.eps

V 1000 A 40 A 600 A A 600 V 1000 A ZERO INRUSH MIN MAX HOLD 319 TRUE RMS CLAMP METER CAT 600V COM V OFF V 1000 A 40 A 600 A A 600 V 1000 A A AC 100 ms A INRUSH Hz Hz 9 A etr119.eps Off On

etr123.eps