Thermal Overcurrent Circuit Breaker 3130 www.e-t-a.de1646
Description
Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double pole version, protection on one pole only. Illumination is optional and there is a choice of rocker colours. Approved to CBE standard EN 60934 (IEC 60934). Motors, transformers, solenoids, household and office machines, electrical tools, mobile homes, boating, construction vehicles, medical equipment to EN 60601. 3130 1-pole 3-pole For further details please see chapter: Technical Information Voltage rating AC 240 V; 3 AC 415 V; DC 50 V (UL: AC 250 V; 3 AC 250 V; DC 50 V) Current ratings 0.1...20 A 1-pole 0.1...16 A 2- and 3-pole Typical life 1-pole AC 240 V: 0.1...20 A 30,000 operations at 1 x IN, inductive DC 50 V: 0.1...4 A 30,000 operations at 1 x IN, inductive 4.5...16 A 30,000 operations at 1 x IN, resistive DC 28 V: 0.1...20 A 30,000 operations at 1 x IN, inductive 2-pole AC 240 V: 0.1...16 A 50,000 operations at 1 x IN, inductive DC 50 V: 0.1...16 A 50,000 operations at 1 x IN, inductive 3-pole 3 AC 415 V: 0.1...16 A 30,000 operations at 1 x IN, inductive Insulation co-ordination rated impulse pollution (IEC 60664 and 60664 A) withstand voltage degree 2.5 kV 2 reinforced insulation in operating area Dielectric strength (IEC 60664 and 60664A) test voltage operating area AC 3,000 V current path/current path AC 1,500 V Insulation resistance > 100 MΩ (DC 500 V) Interrupting capacity Icn 0.1...2 A 10 x IN 2.5...20 A 150 A 1-pole 2.5...16 A 250 A 2-pole 2.5...12 A 150 A 3-pole 14 + 16 A 130 A 3-pole Interrupting capacity (UL 1077) Degree of protection operating area IP40 (IEC 60529/DIN 40050) terminal area IP00 Vibration 5 g (57-500 Hz) ± 0.38 mm (10-57 Hz) to IEC 60068-2-6, test Fc 10 frequency cycles/axis Shock 1-pole: 25 g (11 ms) 2 + 3-pole: 20 g (11 ms) to IEC 60068-2-27, test Ea Corrosion 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka Humidity 240 hours at 95 % RH, to IEC 60068-2-78, test Cab Mass approx. 45 g (three pole) approx. 31 g (double pole) approx. 17 g (single pole) Standard current ratings and typical internal resistance values Illumination voltage/power consumption Current rating (A) Internal resistance per pole (Ω) Current rating (A) Internal resistance per pole (Ω) 0.1 94 4 0.0435 0.2 24 5 0.0325 0.3 12 6 0.0215 0.4 5.30 7 0.0165 0.5 4.20 8 0.0165 0.8 1.50 10 < 0.02 1 0.9 12 < 0.02 1.2 0.80 14 < 0.02 1.5 0.45 15 < 0.02 2 0.27 16 < 0.02 2.5 0.0785 18 < 0.02 3 0.0595 20 < 0.02 3.5 0.0565 IN UN Inc 1, 2-pole 0.1...16 A AC 250 V 3500 A 3-pole 0.1...12 A 3 AC 250 V 5000 A 1,2-pole 0.1...16 A DC 50 V 2000 A operating voltage power consumption 1-pole 2-/3-pole 2-/3-pole Y+R G 12 V 9 mA 2 mA 3.5 mA 24 V 9 mA 2 mA 3.5 mA 48 V 9 mA 2 mA 3.5 mA 115 V < 1 mA 0.9 mA 2.8 mA 230 V < 1 mA 0.9 mA 2.8 mA 400 V - 0.9 mA 2.8 mA
Thermal Overcurrent Circuit Breaker 3130 www.e-t-a.de 1646 Ordering information - 1-pole Type No. 3130 single pole thermal circuit breaker Mounting F snap in frame Frame 1 standard Number of poles 1 single pole, thermally protected Frame mounting 0 panel thickness 1-2.5 mm (.039-.099 in) Terminal design P7 blade terminals DIN 46244-C-Ms-S (QC 2x.110) H7 for terminals 1.1, 2.1 3.1 terminal screws M 3.5 for terminals 1.2, 2.2, 3.2 blade terminals (QC 2x.110) Characteristic curve T1 thermal 1.05-1.4 I N Actuator style W rocker switch with marking „I“ and „O“ moulded in Actuator colour
01 Q black opaque without illumination
02 Q white opaque without illumination
04 Q red opaque without illumination
14 Q R red translucent with LED-illumination
15 Q Y orange translucent with
19 Q G green translucent with
LED-illumination (DC only) Illumination voltage range* 2 10 - 14 V DC 3 20 - 28 V DC 6 90 - 140 V AC 7 185 - 275 V AC Current ratings 0,1...20 A 3130 - F 1 1 0 - P7 T1 - W 14 Q R 3 - 5 A ordering example * N/A for non-illuminated versionPreferred types 3130 1-pole Standard current ratings (A) 1 2 3 4 5 8 10 15 16 20 3130-F110-P7T1- W01Q- x x x x x x x x x x Ordering information - multipole Type No. 3130 multipole thermal circuit breaker Mounting F snap in frame Frame 1 standard A version for X3130 Number of poles 2 2-pole thermally protected 3 3-pole thermally protected 5 2-pole, 1-pole thermally protected Frame mounting 0 panel thickness 1-2.5 mm (.039-.099 in) A 2-pole, version for X3130 Terminal design P7 blade terminals DIN 46244-C-Ms-S (characteristic curve T1) H7 for terminals 1.1, 2.1 3.1 terminal screws M 3.5 for terminals 1.2, 2.2, 3.2 blade terminals (QC 2x.110) Characteristic curve T1 thermal 1.05-1.4 I N Actuator style W rocker switch with marking „I“ and „O“ moulded in Actuator colour
14 Q R red translucent with
Illumination voltage range* 2 10 - 14 V DC 3 20 - 28 V DC 6 90 - 140 V AC 7 185 - 275 V AC 8 320 - 450 V AC Current ratings 0,1...16 A 3130 - F 1 3 0 - P7 T1 - W 14 Q R 7 - 5 A ordering example * N/A for non-illuminated version Preferred types Approvals Authority Standard Rated voltage Current ratings VDE IEC/EN 60934 AC 240 V AC 240/415 V DC 50 V DC 50 V DC 28 V
0.1 A…20 A (single pole)
0.1 A…16 A (multipole)
0.1 A…8 A (single pole)
0.1 A…16 A (1 + 2 pole)
0.1 A…12 A (3 pole)
0.1 A…16 A (1 – 3 pole)
CSA C22.2 No 235 AC 250 V AC 250 V DC 50 V
Thermal Overcurrent Circuit Breaker 3130 www.e-t-a.de1646 Thermal Overcurrent Circuit Breaker 3130 Dimensions terminal for illumination conductor size 0.14 mm 2 (AWG26), length 180 mm (7.09 in.) +0.3 +.012 26.1+0.2 29.5 optional illumination 2 I +0.3 +.012 blade terminals DIN 46244-C-Ms-S (QC 2x.110 P7 or N7) 9.5OFF ON 5.85 233 14.5 34+0.2 14.6+0.2 min. 1.5 < R0.5 ±0.1 panel thickness 1-2.5 mm (.039-.098 in.) Panel cut-out I.2 LINE I.I Side view LINE I.I flat head screw M3.5x5 -MS ISO 1580 (H7) tightening torque max. 0.8 Nm I.3 -0.4 -0.2 switch only .230 .079 .374 .571 ±.004 < .020 -.016 -.008 min .059 .709 1.42 1.34+.008 .575+.008 .394 1.30 .079 .787 1.34 3130-F110-… blade terminals DIN 46244-C-Ms-S (QC 2x.110 P7 or N7) OFF ON 5.85 233 34+0.2 min. 1.5 < R0.5±0.1 panel thickness 1-2.5 mm (.039-.098 in.) Panel cut-out I.2 LINE I.I Side view LINE I.I flat head screw M3.5x5 -MS ISO 1580 (H7) tightening torque max. 0.8 Nm I.3 Edges of working parts: DIN 6784 .230 .079 .827 1.02 ±.004 < .020 min .059 1.16 1.42 1.34+.008 1.03+.008 .394 1.30 .079 .787 1.34 3130-F120-… unit .118 optional illumination R3.118 -0.4 -0.2 +0.3 +.012 2 unitI3 37.6+0.2 optional illumination 37.5 32.5 blade terminals DIN 46244-C-Ms-S (QC 2x.110 P7 or N7) OFF ON 5.85 233 34+0.2 min. 1.5 < R0.5 ±0.1 panel thickness 1-2.5 mm (.039-.098 in.) Panel cut-out I.2 LINE I.I Side view LINE I.I flat head screw M3.5x5 -MS ISO 1580 (H7) tightening torque max. 0.8 Nm I.3 Edges of working parts: DIN 6784 .230 .079 1.28 1.48 ±.004 < .020 min .059 1.61 1.42 1.34+.008 1.48+.008 .394 1.30 .079 .787 1.34 .118 3130-F130-… -.016 -.008 This is a metric design and millimeter dimensions take precedence ( mm ) inch Internal connection diagrams I.2 line 1.1 1-pole lamp 3.1 3.2 2.1 2.21.2 line 1.1 3-pole load load load load 2-pole 2.1 2.21 .2 line 1.1 load load 1.3
Thermal Overcurrent Circuit Breaker 3130 www.e-t-a.de 1646 The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section Technical information. Ambient °F temperature °C -22 -30 -20 +14 -10 +32 +73.4 +23 +104 +40 +122 +50 +140 +60 Trip time in seconds +23 °C +73.4 °F +60 °C +140 °F -30 °C -22 °F … times rated current Trip time in seconds +23 °C +73.4 °F +60 °C +140 °F -30 °C -22 °F 12 46 81 02 04 0 10000 1000 100 0.1 0.1…2 A 2.5…20 A 1-pole 2.5…16 A 2- and 3-pole Multipole types: all poles symmetrically loaded. With single pole overload, thermal tripping will be at approx. 1.54 x IN with 2-pole devices and at approx. 1.68 x IN with 3-pole devices. 12 46 81 02 04 0 10000 1000 100 0.1 … times rated current This is a metric design and millimeter dimensions take precedence ( mm ) inch Installation drawing 3130-F1... mounting area When installing the circuit breaker apply pressure on bezel only. I.2 LINE I.II.3 1032 58 7 operating area .984 1.26 .276.276.315 .787 .197 .394 Accessories 3130-F130-... Typical time/current characteristics ø4.4 .173 36.5 1.44 41.5 1.63 1.97 .197 .472 .315 1.97 .433 2.17 ø11 Splash cover, transparent, for 3-pole version X 221 258 01 (IP54), comprising bezel Y 306 109 01 and transparent cover Y 306 108 01 All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted.
Appliance Inlet Module X3130 for 2-pole circuit breaker 3130-FA.A www.e-t-a.de1646 Thermal Overcurrent Circuit Breaker 3130 Dimensions Mounting hole X3130 40.236.5 Circuit breaker 3130 (2-pole) ø 3.3 I.2 LINE I.I I.3 72 ± 0.2 M3/Ø 3.3 31.6 ± 0.1 63.6 ± 0.15 2.50 2.83 Ø.130 1.24 The appliance inlet module X3130 with double pole circuit breaker 3130-FA.A combines three functions within a single component: A C14 appliance inlet and rocker switch with resettable overcurrent protection; screw mounting from the front or the rear. Electrical medical apparatus, laboratory equipment, professional audio equipment and office machines.
Ordering information
Type No. X3130 Appliance inlet module for circuit breaker type 3130-FA.A Module A appliance inlet C14 Design 04 screw-type mounting Accessories 00 without Version 00 not wired; mounting position 3130: I to connector 01 not wired; mounting position 3130: 0 to connector (standard) Delivery condition M module supplied with circuit breaker FA.A Approvals Technical data Rated voltage AC 240 V Rated current 10 A (IEC)
15 A (UL/CSA)
Ambient temperature -25°C ... 70°C Number of poles L, N + ground Cable cross section max. 1.5 mm2 Degree of protection Class I Mounting method screw-type mounting (front or rear) Terminal design blade terminals DIN 46244 A6.3 x 0.8 Housing material thermoplastics, black UL94V-0 Appliance inlet C14 according to IEC/EN 60320-1, UL 498 Switch circuit breaker type 3130, 2-pole Authority Standard Rated voltage Current ratings UL UL 489 C22.2 No 42
Thermal Overcurrent Circuit Breaker 3130 www.e-t-a.de 1646