DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

Instruction SheetPnuematic Platform Adapters 679992- 1 and 679992- 2 (Used with 408- -4098 LOC B 1 of 5E2010 Tyco Electronics Corporation, Berwyn, PA All Rights Reserved TE logo and Tyco Electronics are trademarks. *Trademark. Other product names, logos, or company names might be trademarks of their respective owners. TOOLING ASSISTANCE CENTER 1- -800- -722- -1111 PRODUCT INFORMATION 1- -800- -522- -6752 This controlled document is subject to change. For latest revision and Regional Customer Service, visit our website atwww.tycoelectronics.com

12 MAR 10 Rev D626 Pneumatic Tooling Assemblies)

Product: Ultra- -Fast Fully Insulated FASTON* Terminals Ultra- -Fast Plus Fully Insulated FASTON Terminals Wire Size: 26- -14 AWG Product Catalog: 82042 Tooling Catalog: 124208 Quick Pin(s) Tool Holder Assembly 189767- -1 (Ref) Rollers Link Locator Stop Pneumatic Platform Adapter 679992- -1 (Ref) Top Jaw Locator Assembly Bottom Jaw 1. INTRODUCTION Pneumatic Platform Adapters 679992- -1 (shown in Figure 1) and 679992- -2 are used with 626 Pneumatic Tooling Assemblies 189721- -1, 189722- -1, 189723- -1, or 189724- -1 when fitted with Tool Holder Assembly 189767- -1. The platform adapter accepts the crimping die assemblies listed in Figure 2 and will crimp Ultra- -Fast FASTON terminals onto wire sizes 26 through 14 AWG. This instruction sheet provides recommended procedures for insulation crimp adjustments, wire preparation, crimp head installation, crimping, and maintenance and inspection. For information concerning the setup and operation of the pneumatic tools, see Customer Manual 409- -5862. Read these instructions thoroughly before proceeding. Dimensions in this instruction sheet are in millimeters [with inches in brackets]. Figures are not drawn to scale. Reasons for reissue are provided in Section 7, REVISION SUMMARY. CRIMPING DIE ASSEMBLY TERMINAL WIRE SIZE PART NUMBER INSTRUCTION SHEET COLOR DOT CODE TYPE CRIMP DOT CODE WIRE SIZE (AWG) 58052- -3 408- -9277 Violet Ultra- -Fast Fully Insulated FASTON Terminal 3 26- -22 58079- -3 408 9278 Red Ultra- -Fast Plus Fully Insulated NA 22- -18 58080- -3 408- -9278 Blue Ultra--Fast Plus Fully Insulated FASTON Terminal NA 16- -14 90390- -3 408 9279 Red Ultra- -Fast Fully Insulated FASTON 1 22- -18 90391- -3 408- -9279 Blue Ultra--Fast Fully Insulated FASTON Terminal 2 16- -14 Figure 2 ORIGINAL INSTRUCTIONS NOTE i

408- 4098Pneumatic Platform Adapters 679992- 1 and 679992- 2 3 of 5Rev D Tyco Electronics Corporation 2. Insert platform adapter into tool holder as shown in Figure 1. 3. After platform adapter is properly aligned, insert and tighten quick pins provided with the tool holder assembly (refer to Figure 1). We recommend using LOCTITE{ 242 removable threadlock, or equivalent, to prevent the quick pins from loosening.. 4. Connect pneumatic tool to an adequate air supply between 620 and 690 kPa [90 and100 psi]. For specific information on air line requirements and air hose installation, refer to the instructions packaged with the pneumatic tooling assembly. B. Removal To avoid personal injury, ALWAYS disconnect tool from air supply before removing platform adapter. Remove quick pins from platform adapter; then remove platform adapter from tool holder. 4. CRIMPING PROCEDURE(Figure 4) Strip the wire to the appropriate length according to Application Specification 114- -2123. Proceed as follows: Do NOT operate the tool without the platform adapter or die assembly properly installed. To avoid personal injury or damage to the tool, always keep fingers clear of jaws, and frequently check the quick pins to ensure that they are secure. 1. The locator stop must be adjusted to accommodate the terminal series size, which is marked on the terminal insulation (.110, .187, or .250). Rotate the blue plastic locator stop until the series size matches the terminal series size. If crimping a flag terminal, the locator stop does NOT need to be adjusted. 2. Open the dies by squeezing the adapter rollers together. 3. Center the terminal wire barrel in the appropriate crimping chamber on the lower die. a. For straight terminals, insert mating end into crimping chamber with the flat side facing the locator assembly (for Adapter - -1) as shown in Figure 4, or the upper die (for Adapter - -2). Allow terminal to butt against the locator stop. b. For flag terminals, orient the terminal as shown in Figure 4. The mating end must be seated on the locator assembly (for Adapter - -1), or the upper die (for Adapter - -2). 4. After terminal is properly positioned, release the adapter rollers to allow the dies to spring shut, holding the terminal in place. 5. Insert stripped wire into wire barrel until the wire bottoms. Strip Length (Ref) Series Size Marking (Must Match Terminal Series Size) Locator StopLocator Assembly (Ref) Ultra- -Fast FASTON Terminals (Ref) { Trademark of Loctite Corporation Figure 4 Lower Die Upper Die NOTE i DANGER CAUTION DANGER NOTE i

408- 4098Pneumatic Platform Adapters 679992- 1 and 679992- 2 Rev D4 of 5 Tyco Electronics Corporation 6. Activate tool to complete the crimp. Open the jaws by squeezing the adapter rollers together; then remove the crimped terminal. 7. Inspect terminal in accordance with 114- -2123 to ensure a proper crimp. A properly crimped terminal will display a crimp dot code on the flat side of the terminal insulation. For applicable crimp dot codes, refer to Figure 2. Flag terminals will not have a crimp dot code. 5. MAINTENANCE AND INSPECTION To avoid injury, DISCONNECT TOOL FROM AIR SUPPLY before performing any maintenance or inspection procedures. It is recommended that a maintenance and inspection program be performed periodically to ensure dependable and uniform terminations. The platform adapter should be inspected once a month. Frequency of inspection should be adjusted to suit your requirements, and depends on: 1. The care, amount of use, and handling of the adapter. 2. The type and size of the products crimped. 3. The degree of operator skill. 4. The presence of abnormal amounts of dust and dirt. 5. Your own established standards. The platform adapter is thoroughly inspected before packaging. Since there is the possibility of damage during shipment, the adapter should be inspected immediately upon arrival at your facility. 5.1. Maintenance A. Cleaning Remove dust, moisture, and other contaminants with a clean, soft brush, or a soft, lint- -free cloth. Do NOT use objects that could damage the adapter. Re- -lubricate adapter, as instructed in Paragraph 5.1.B. Lubrication, before placing it back into service. B. Lubrication Lubricate all pins, pivot points, and bearing surfaces with a high quality grease. The use of MolykoteH grease, which is a commercially available lubricant, is recommended. Lubricate according to the following schedule: Adapter used in daily production—lubricate daily Adapter used daily (occasional)—lubricate weekly Adapter used weekly—lubricate monthly Wipe excess grease from adapter, particularly from die closure areas. Grease transferred from the die closure area onto certain terminations may affect the electrical characteristics of an application. 5.2. Periodic Inspection 1. Inspect the adapter for missing pins and retaining rings. If parts are missing or defective, replace them by referring to Section 6. 2. Check all bearing surfaces for wear. Make sure the rollers turn freely with minimal resistance. Replace any worn parts. 3. Inspect the crimping area for flattened, chipped, or broken areas. Worn or damaged surfaces are objectionable and will affect the quality of the crimp. 6. REPLACEMENT AND REPAIR The parts listed in Figure 5 are customer- - replaceable. A complete inventory can be stocked and controlled to prevent lost time when replacement of parts is necessary. Order replacement parts through your representative, or call 1- -800- -526- -5142, or send a facsimile of your purchase order to 1- -717- -986- -7605, or write to: CUSTOMER SERVICE (38- -35) TYCO ELECTRONICS CORPORATION P.O. BOX 3608 HARRISBURG, PA 17105- -3608 Tools may also be returned for evaluation and repair. For tool repair service, contact a representative at 7. REVISION SUMMARY Revisions to this instruction sheet include: S Added “Original Instructions” GTrademark of Dow Corning Corporation NOTE i NOTE DANGER

408- 4098Pneumatic Platform Adapters 679992- 1 and 679992- 2 5 of 5Rev D Tyco Electronics Corporation 16 15 14 4 17 13 12 1 REPLACEMENT PARTS ITEM PART NUMBER DESCRIPTION QUANTITY PER ADAPTER 1 217450- -1 Jaw, Assembly, Bottom 1 2 217451- -1 Jaw, Assembly, Top 1 3 679261- -1 Link 2 4 21061- -1 Setscrew, Socket Head 2 5 310952- -2 Jaw, Platform 1 6 122637- -1 Pin, Toggle Link 1 7 122701- -1 Spring } 1 8 312388- -1 Locator Assemblyg 1 9 3- -23620- -3 Pin, Straight Groove} 2 10 21045- -6 Ring, Retaining} 4 11 314479- -2 Roller } 4 12 6- -23629- -1 Pin, Straight Groove 2 13 1- -21048- -0 Ring, Retaining 4 14 21028- -8 Pin, Slotted Spring 1 15 310690- -1 Spring, Extension 1 16 679495- -2 Pin 1 301185- -6 Shim, 0.20 mm [.008 in.]D At Request 301185- -7 Shim, 0.25 mm [.010 in.]D At Request 17 301185- -8 Shim, 0.30 mm [.012 in.]D At Request 301185- -9 Shim, 0.38 mm [.015 in.]D At Request } Recommended Spare Parts gLocator Assembly (Item 8 ) is not a component of Adapter 679992- -2. Figure 5