Interactive Catalog Replaces Catalog Pages Sensing and Control Honeywell Inc.
11 West Spring Street
Freeport, Illinois 61032 Honeywell Sensing and Control has replaced the PDF product catalog with the new Interactive Catalog. The Interactive Catalog is a power search tool that makes it easier to find product information. It includes more installation, application, and technical information than ever before. Click this icon to try the new Interactive Catalog.
26 HoneywellSensingandControlForapplicationhelp:call1-800-537-6945. CUT -A-WAY SM SUBMINIATURE BASIC SWITCH AVAILABLE TERMINALS Various terminals are available for most listings. These include: the T and T2 for wrap-around soldering of leadwires; sol- der terminals for solder connections; H58 terminals and H4 series terminals provide easy quick-connect installation; H2 type, round wire wrap or PC terminals; H6 rect- angular wire wrap terminals are also avail- able. Other quick-connect terminals of the Series H types are available. Contact the 800 number for ordering information. GENERAL INFORMATION SM subminiature switches are slightly larger than the SX switches. These switches combine small size and light weight with ample electrical capacity, pre- cision operation and long life. Unless oth- erwise noted, all listings have silver con- tacts. T SOLDER T2 H4 H58 H2 Mates with Amp Inc. Part No. 640024-1 Std. Dimensions shown are for reference only
FEATURES
1 Low operating force to 2 ounces
1 Sensitive differential travel as low as
.001 inch (0,025 mm) maximum
1 Power load switching capability
available to 11 amps (VAC) – silver contacts
1 Motor load handling capacity to 1/4
hp (VAC)
1 Optional gold contacts for low energy
applications
1 Optional bifurcated gold contacts for
1 Long mechanical life
– 11SM Series 10,000,000 operations – 1SM/41SM Series 80,000 operations – Bifurcated contacts 1,000,000 operations All at 95% survival
1 Standard temperature range −65° to
1 High temperature construction
°F (204°C) for 100 hours
1 Variety of integral and auxiliary
1 Choice of several terminal styles
1 Military Standard construction
available with three listings on the MIL-S-8805 qualified products list
1 UL recognized File #E12252, CSA
certified File #LR41372 Mounting Torque: 2.3 inch pounds max. This section covers only 38 of our most popular SM Series catalog listings. If you don’t find what you’re looking for, it’s likely one of the approximately 500 other active SM listings will meet your needs. Contact the 800 number.
Forapplicationhelp:call1-800-537-6945.HoneywellSensingandControl27 Characteristics: O.F . — Operating Force; R.F . — Release Differential Travel; O.P . — Operating Position. ORDER GUIDE by ascending electrical capability Catalog UL Code newtons newtons mm mm mm mm Listing Recommended For Page 20 ounces ounces inches inches inches inches 11SM1077-T Gold alloy contacts .1 Amp 0,83-1,39 0,28 0,51 0,13 0,1 8,38 P 3-5 1 .020 .005 .004 .330 12SM604-T Bifurcated gold contacts, .1 Amp 0,83-1,39 0,28 0,51 0,076 0,1 8,38 reduced rating P 3-5 1 .020 .003 .004 .330 contacts N 3-5 1 .020 .005 .004 .330 12SM4-T Best reliability 1 Amp 0,83-1,39 0,28 0,51 0,076 0,1 8,38 (Bifurcated gold contacts) N 3-5 1 .020 .003 .004 .330 11SM701-T Lower force 4 Amps 0,56 0,14 0,51 0,13 0,051 8,38 11SM1-T Most applications 5 Amps 0,83-1,39 0,28 0,51 0,13 0,1 8,38 J 3-5 1 .020 .005 .004 .330 11SM3-T Operating in temperatures 5 Amps 0,83-1,39 0,28 0,51 0,13 0,1 8,38 to +250 °F (121°C) J 3-5 1 .020 .005 .004 .330 11SM244-T Operating in temperatures 5 Amps 0,83-1,39 0,28 0,51 0,13 0,1 8,38 to +400 11SM401-T Less differential travel 5 Amps 0,97 0,28 0,51 0,13 0,025 8,38 max. 21SM284-T2 MIL-S-8805 application 5 Amps 0,83-1,39 0,28 0,76 0,13 0,1 8,38 (MS25085-2) requirements R 3-5 1 .030 .005 .004 .330 21SM284 MIL-S-8805 application 5 Amps 0,83-1,39 0,28 0,76 0,13 0,1 8,38 (MS25085-1) requirements, R 3-5 1 .030 .005 .004 .330 solder terminals 22SM1-T Best stability under 5 Amps 0,83-1,39 0,28 0,51 0,13 0,1 8,38 varying humidity J 3-5 1 .020 .005 .004 .330 41SM1-T Up to 11 ampere 1/4 hp 11 Amps 0,83-1,39 0,28 0,76 0,13 0,1 8,38 (AC) load handling M 3-5 1 .030 .005 .004 .330 Dim. Dwg. Fig. 1 *For electrical data call 1-800-537-6945 411SM1 Sealed plunger construction
5 Amps 0,83-2,09 0,28 0,51 0,13 0,1 8,38
411SM23 As above with gold contacts
1 Amp 0,83-2,09 0,28 0,51 0,13 0,1 8,38
Except where stated * ±0,38mm ±.015 in. Miniature/ Subminiature
28 HoneywellSensingandControlForapplicationhelp:call1-800-537-6945. Characteristics: O.F . — Operating Force; R.F . — Release Travel; O.P . — Operating Position. ORDER GUIDE INTEGRAL LEVERS Electrical Catalog UL Code newtons newtons mm mm mm mm Listing Description Page 20 ounces ounces inches inches inches inches 311SM1-T .285 inch (7,24mm) 5 Amps 0,39 0,07 2,16 0,51 0,48 8,64 ±1,5 311SM23-T As above with gold 1 Amp 0,39 0,07 2,16 0,51 0,48 8,64 ±1,5 311SM701-T .285 inch (7,24mm) 4 Amps 0,16 0,03 2,16 0,51 0,36 8,64 ±1,5 straight lever. Lower force Dim. Dwg. Fig. 4 311SM2-T .565 inch (14,35mm) 5 Amps 0,31 0,05 3,05 0,66 0,69 8,51 ±2 311SM43-T As above with gold 1 Amp 0,31 0,05 3,05 0,66 0,69 8,51 ±2 311SM702-T .565 inch (14,35mm) 4 Amps 0,11 0,02 3,05 0,66 0,38 8,51 ±2 straight lever. Lower force Dim. Dwg. Fig. 5 311SM3-T 1.765 inch (44,8mm) 5 Amps 0,15 0,02 7,87 1,45 2,8 7,11 ±4,3 311SM17-H58 As above with gold 1 Amp 0,15 0,02 7,87 1,45 2,8 7,11 ±4,3 311SM703-T 1.765 inch (44,8mm) 4 Amps 0,06 0,01 7,87 1,45 1,78 7,11 ±4,3 straight lever. Lower force Dim. Dwg. Fig. 6 311SM4-T .251 inch (6,38mm) 5 Amps 0,39 0,07 2,16 0,46 0,48 11,7 ±1,5 311SM25-T As above with gold 1 Amp 0,39 0,07 2,16 0,46 0,48 11,7 ±1,5 311SM704-T .251 inch (6,38mm) 4 Amps 0,16 0,03 2,16 0,46 0,33 11,7 ±1,5 Lower force Dim. Dwg. Fig. 7 311SM5-T .535 inch (13,6mm) 5 Amps 0,31 0,05 3,05 0,66 0,69 11,56 ±2 311SM705-T .535 inch (13,6mm) 4 Amps 0,11 0,02 3,05 0,66 0,38 11,56 ±2 Lower forceDim. Dwg. Fig. 8 311SM6-T .251 inch (6,38mm) 5 Amps 0,39 0,07 2,16 0,46 0,48 14,2 ±1,5 311SM68-T As above with gold 1 Amp 0,39 0,07 2,16 0,46 0,48 14,2 ±1,5 311SM706-T .251 inch (6,38mm) 4 Amps 0,16 0,03 2,16 0,46 0,33 14,2 ±1,5 roller lever. Lower force Dim. Dwg. Fig. 9 311SM7-T .535 inch (13,6mm) 5 Amps 0,31 0,05 3,05 0,66 0,69 14,1 ±2 Dim. Dwg. Fig. 10
Forapplicationhelp:call1-800-537-6945.HoneywellSensingandControl29 ORDER GUIDE INTEGRAL LEAF Electrical Catalog UL Code newtons newtons mm mm mm mm Listing Recommended For Page 20 ounces ounces inches inches inches inches 111SM1-T Force and stability of 5 Amps 1,95 0,56 5,54 0,76 0,76 8,89 ±0,76 111SM17-T As above with gold 1 Amp 1,95 0,56 5,54 0,76 0,76 8,89 ±0,76 Dim. Dwg. Fig. 11 111SM2-T Flexible leaf with roller 5 Amps 1,95 0,56 5,56 0,76 0,64 14,3 ±0,76 111SM23-T As above with gold 1 Amp 1,95 0,56 5,56 0,76 0,64 14,3 ±0,76 Dim. Dwg. Fig. 12 Miniature/ Subminiature
30 HoneywellSensingandControlForapplicationhelp:call1-800-537-6945. Characteristics: O.F . — Operating Force; R.F . — Release Force; — Operating Position; F .P . — Free Position * All characteristics are taken with actuator assembled to Catalog Listing 11SM3-T as shown. ORDER GUIDE AUXILIARY ACTUATORS Switches are not included with the actuators. Actuator Length Catalog mm newtons newtons mm mm mm mm mm Listing Description inches ounces ounces inches inches inches inches inches JS-2 Straight leaf 16,8 2,78 0,56 1,98 0,38 0,38 8,89 ±0,38 11,3 Dim. Dwg. Fig. 14 JS-5 Roller leaf 15 2,78 0,83 1,98 0,38 0,38 14,2 ±0,38 16,9 Dim. Dwg. Fig. 14 JS-7 Formed leaf 14,7 2,78 0,56 2,39 0,79 0,38 9,65 ±0,38 12,1 (Simulated roller) Dim. Dwg. Fig. 14 JS-220 Straight lever 26,2† 0,28 0,04 3,18 0,76 0,76 10,3 — Dim. Dwg. Fig. 16 JS-246 Roller lever 25,4† 0,28 0,04 3,18 0,76 0,76 14,3 — Dim. Dwg. Fig. 16 JS-221 Formed lever 25,4† 0,28 0,04 3,18 0,76 0,76 11,6 — (Simulated roller) Dim. Dwg. Fig. 16 JS-33 Tandem leaf 5,3 5,00 2,78 2,36 0,15 0,38 8,89 ±0,38 10,5 JS-31 Tandem roller leaf 4,3 11,1 4,45 2,36 0,13 0,38 14,5 ±0,38 16,1 (Bronze roller) **Travel characteristics on tandem actuators vary with actual basic switch characteristics. NOTE: Above actuators should be used below+300°F. See page 79 for other actuators that may be used with SM Switches at higher temperatures. ‘‘A’’ measurement is from the pivot point of lever to the point indicated on drawing.
Forapplicationhelp:call1-800-537-6945.HoneywellSensingandControl31 MOUNTING DIMENSIONS (for reference only) PIN PLUNGER Fig. 1 Fig. 2 INTEGRAL LEVERS Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10 INTEGRAL LEAFS Fig. 11 Fig. 12 AUXILIARY ACTUATORS Fig. 14 Fig. 16 Switches are not included with the actuators. Mounting holes accept pins or screws of .087 inch (2,21 mm) max. diameter Miniature/ Subminiature