3118A BELDEN | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 2
Technical content
Product: 3118A Inst, 16 Tri #16 Str BC, PVC-NYL Ins E1, IS/OS, Blk PVC Jkt, 600V TC-ER 150V NPLF 90C Dry 90C Wet Product Description UL Instrumentation, 16 Triad 16AWG (7x24) Bare Copper, PVC-NYL Insulation E1 Color Code, Individual & Overall Beldfoil® Shield, Black PVC Outer Jacket, 600V TC-ER 150V NPLF 90C Dry 90C Wet SUN RES DIR BUR Technical Specifications Product Overview Suitable Applications: Industrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, ...),low voltage digital control (24v, …),RTD, control circuits, distributed control system (DCS),programmable logic controller (PLC), Solenoids, Valves, actuators, positioners Construction Details Conductor Element No. of Elements Size Stranding Material Triad(s) 16 16 AWG 7x24 BC - Bare Copper Insulation Element Material Nom. Thickness Color Code Triad(s) PVC/Nylon - Polyvinyl Chloride + Nylon 0.022 in (0.56 mm) Black, White, Red and Numbered Inner Shield Element Shield Type Material Coverage Drainwire Type Triad(s) Tape Bi-Laminate (Alum+Poly) 100% 18 AWG (7x26) TC Outer Shield Shield Type Material Coverage Drainwire Type Tape Bi-Laminate (Alum+Poly) 100% 16 AWG (7x24) TC Outer Jacket Material Nom. Thickness Nom. Diameter Ripcord PVC - Polyvinyl Chloride 0.083 in (2.1 mm) 1.158 in (29.41 mm) Yes Overall Cable Diameter (Nominal): 1.158 in (29.41 mm)
Electrical Characteristics
Element Nom. Conductor DCR Nom. Inner Shield DCR Triad(s) 3.67 Ohm/1000ft (12.0 Ohm/km) 4.99 Ohm/1000ft (16.4 Ohm/km) Voltage UL Voltage Rating
600 V (TC), 150 V (NPLF)
Mechanical Characteristics Temperature UL Temperature Operating
90°C Dry, 90°C Wet -30C to 90C Dry, 90C Wet Bend Radius Stationary Min. Installation Min. 11.6 in (295 mm) 11.6 in (295 mm) Max. Pull Tension: 1771 lbs (803.3 kg) Bulk Cable Weight: 838 lbs/1000ft Standards and Compliance Environmental Suitability: Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial Flammability / Reaction to Fire: UL1685 (FT4 Loading), FT4, 1202 NEC / UL Compliance: Article 336, Article 760, NPLF, TC-ER History Update and Revision: Revision Number: 0.176 Revision Date: 01-04-2024 © 2024 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.