DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

Description

22 AWG stranded (7x30) tinned copper conductors, Datalene® insulation, twisted pairs, overall Beldfoil® shield (100% coverage) plus a tinned copper braid (65% coverage), drain wire, UV resistant Haloarrest XLink2 jacket. Physical Characteristics (Overall): Conductor: AWG # Pairs AWG Stranding Conductor Material Dia. (in.) 1 22 7x30 TC - Tinned Copper 0.030 Total Number of Conductors 2 Insulation: Insulation Material Insulation Trade Name Insulation Material Datalene® FHDPE - Foam High Density Polyethylene Outer Shield: Outer Shield Material Layer # Outer Shield Trade Name Type Outer Shield Material Coverage (%) 1 Beldfoil® Tape Aluminum Foil-Polyester Tape 100.000 2 Braid TC - Tinned Copper 65.000 Outer Shield Drain Wire AWG AWG Stranding Drain Wire Conductor Material 22 7x30 TC - Tinned Copper Outer Jacket: Outer Jacket Material Outer Jacket Material Haloarrest Xlink2 Overall Cable: Overall Nominal Diameter: 0.4 in. Pair: Pair Color Code Chart Number Color

1 White/Blue Stripe and Blue/White Stripe

Pair Lay Length & Direction Lay Length (in.) 3.750 Mechanical Characteristics (Overall): Operating Temperature Range -20°C To +60°C Bulk Cable Weight: 109 lbs/1000 ft. Max. Recommended Pulling Tension: 60 lbs. Min. Bend Radius/Minor Axis: 4 in. Applicable Specifications and Agency Compliance (Overall): Applicable Standards & Environmental Programs: NEC/(UL) Specification CMG, PLTC Page 1 of 3 02-16-2017 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 3105Z Multi-Conductor - EIA Industrial RS-485 PLTC/CMG

CEC/C(UL) Specification CMG EU Directive 2011/65/EU (ROHS II) Yes IEEE Specification 45 EU CE Mark Yes EU Directive 2000/53/EC (ELV) Yes EU Directive 2002/95/EC (RoHS) Yes EU Directive 2002/96/EC (WEEE) Yes EU Directive 2003/11/EC (BFR) Yes CA Prop 65 (CJ for Wire & Cable) Yes MII Order #39 (China RoHS) Yes Flame Test: UL Flame Test UL1685 FT4 Loading C(UL) Flame Test FT4 IEC Flame Test 60332-3-22 (Category A) Suitability: Sunlight Resistance Yes Plenum/Non-Plenum: Plenum (Y/N) No Electrical Characteristics (Overall): Nom. Characteristic Impedance Impedance (Ohm) 120 Nom. Capacitance Conductor to Conductor Capacitance (pF/ft) 11.000 Nom. Capacitance Cond. to Other Conductor & Shield Capacitance (pF/ft) 20.900 Nominal Velocity of Propagation VP (%) 78.000 Nom. Conductor DC Resistance DCR @ 20°C (Ohm/1000 ft) 14.700 Nominal Outer Shield DC Resistance DCR @ 20°C (Ohm/1000 ft) 2.800 Nom. Attenuation Description Freq. (MHz) Start Freq. (MHz) Stop Freq. (MHz) Attenuation (dB/100 ft.) 1.000 0.500 Max. Operating Voltage - UL Voltage

300 V RMS (NEC Type PLTC)

300 V RMS (NEC Type CM)

Max. Recommended Current Current

2.7 Amps per conductor @ 25°C

Other Electrical Characteristic 1 Input Impedance/Unfitted Impedance .5 - 10 MHZ, 120 +-12 Ohms Revision Number: 0 Revision Date: 10-31-2014 Page 2 of 3 02-16-2017 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 3105Z Multi-Conductor - EIA Industrial RS-485 PLTC/CMG

© 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU). Page 3 of 3 02-16-2017 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 3105Z Multi-Conductor - EIA Industrial RS-485 PLTC/CMG