30EPH06PBF IRF | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 7

Technical content

Features

VRRM Peak Repetitive Reverse Voltage 600 V IF(AV) Average Rectifier Forward Current @ T C = 116°C 30 A IFSM Non Repetitive Peak Surge Current @ T J = 25°C 300 TJ, TSTG Operating Junction and Storage Temperatures - 65 to 175 °C Parameters Max Units Case Styles 30EPH06PbF TO247 State of the art Hyperfast recovery rectifiers designed with optimized performance of forward voltage drop, Hyperfast recover time, and soft recovery. The planar structure and the platinum doped life time control guarantee the best overall performance, ruggedness and reliability characteristics. These devices are intended for use in PFC Boost stage in the AC-DC section of SMPS, inverters or as freewheeling diodes. The IR extremely optimized stored charge and low recovery current minimize the switching losses and reduce over dissipation in the switching element and snubbers. ANODE BASE COMMON CATHODE CATHODE www.irf.com

2 www.irf.com VBR, Vr Breakdown Voltage, 600 - - V I R = 100µA Blocking Voltage VF Forward Voltage - 2.0 2.6 V I F = 30A, TJ = 25°C - 1.34 1.75 V I F = 30A, TJ = 150°C IR Reverse Leakage Current - 0.3 50 µA V R = VR Rated - 60 500 µA T J = 150°C, VR = VR Rated CT Junction Capacitance - 33 - pF V R = 600V LS Series Inductance - 3.5 - nH Measured lead to lead 5mm from package body Electrical Characteristics @ TJ = 25°C (unless otherwise specified) Parameters Min Typ Max Units Test Conditions trr Reverse Recovery Time - 28 35 ns I F = 1.0A, diF/dt = 50A/µs, VR = 30V -3 1 - T J = 25°C 77 - T J = 125°C IRRM Peak Recovery Current - 3.5 - A T J = 25°C Qrr Reverse Recovery Charge - 65 - nC T J = 25°C - 345 - T J = 125°C Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified) IF = 30A VR = 200V diF /dt = 200A/µs Parameters Min Typ Max Units Test Conditions Parameters Min Typ Max Units TJ Max. Junction Temperature Range - 65 - 175 °C TStg Max. Storage Temperature Range - 65 - 175 RthJC Thermal Resistance, Junction to Case Per Leg - 0.5 0.9 °C/W RthJA Thermal Resistance, Junction to Ambient Per Leg - - 70 RthCS Thermal Resistance, Case to Heatsink - 0.4 - Wt Weight - 6.0 - g - 0.22 - (oz) Mounting Torque 6.0 - 12 Kg-cm 5.0 - 10 lbf.in Case Style TO-247AC Device Marking 30EPH06 Thermal - Mechanical Characteristics c Typical Socket Mount d Mounting Surface, Flat, Smooth and Greased d c

3www.irf.com 30EPH06PbF Bulletin PD-20879 11/04 Fig. 1 - Typical Forward Voltage Drop Characteristics Fig. 4 - Max. Thermal Impedance Z thJC Characteristics Forward Voltage Drop - VFM (V) Instantaneous Forward Current - I F (A) Reverse Voltage - VR (V) Reverse Voltage - VR (V) Junction Capacitance - C T ( p F ) t1, Rectangular Pulse Duration (Seconds) Thermal Impedance Z thJC (°C/W) Fig. 3 - Typical Junction Capacitance Vs. Reverse Voltage Reverse Current - I R (µA) Fig. 2 - Typical Values Of Reverse Current Vs. Reverse Voltage 100 1000 00 . 511 . 522 . 533 . 5 T = 175˚C T = 150˚C T = 25˚C J J J 0.0001 0.001 0.01 0.1 100 1000 0 100 200 300 400 500 600 25˚C Tj = 175˚C 100˚C 125˚C 150˚C 100 1000 0 100 200 300 400 500 60 0 T = 25˚CJ 0.001 0.01 0.1 Single Pulse (Thermal Resistance) D = 0.50 D = 0.20 D = 0.10 D = 0.05 D = 0.02 D = 0.01 PDM Notes: 1. Duty factor D = t1/ t2 2. Peak Tj = Pdm x ZthJC + Tc

4 www.irf.com Fig. 5 - Max. Allowable Case Temperature Vs. Average Forward Current Fig. 6 - Forward Power Loss Characteristics (3) Formula used: TC = TJ - (Pd + PdREV) x RthJC ; Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6); PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = rated VR Average Forward Current - IF(AV) (A) Average Forward Current - IF(AV) (A) Fig. 7 - Typical Reverse Recovery vs. di F /dt Allowable Case Temperature (°C) Average Power Loss ( Watts ) trr ( ns ) Qrr ( nC ) di F /dt (A/µs )di F /dt (A/µs ) 0 5 10 15 20 25 30 35 40 45 DC RMS Limit D = 0.01 D = 0.02 D = 0.05 D = 0.1 D = 0.2 D = 0.5 Fig. 8 - Typical Stored Charge vs. di F /dt 100 120 140 160 180 0 5 10 15 20 25 30 35 40 45 DC see note (3) Square wave (D = 0.50) Rated Vr applied 100 1000 IF = 30 A IF = 15 A R J J V = 200V T = 125˚C T = 25 ˚C 200 400 600 800 1000 1200 100 1000 IF = 30 A IF = 15 A R J J V = 200V T = 125˚C T = 25 ˚C

5www.irf.com 30EPH06PbF Bulletin PD-20879 11/04 IRFP250 D.U.T. L = 70µH V = 200VR 0.01 Ω G D S dif/dt ADJUST ta tb trr Qrr IF IRRM I RRM0.5 di(rec)M/dt

0.75 IRRM

Fig. 10 - Reverse Recovery Waveform and Definitions Fig. 9- Reverse Recovery Parameter Test Circuit Reverse Recovery Circuit diF /dt diF /dt 4. Qrr - Area under curve defined by t rr and IRRM 5. di (rec) M / dt - Peak rate of change of current during t b portion of t rr 1. diF/dt - Rate of change of current through zero crossing 2. IRRM - Peak reverse recovery current 3. trr - Reverse recovery time measured from zero crossing point of negative going IF to point where a line passing through 0.75 IRRM and 0.50 IRRM extrapolated to zero current Q rr = t rr x I RRM

6 www.irf.com LOT CODE ASSEMBLY INTERNATIONAL RECTIFIEREXAMPLE: IN ASSEMBLY LINE "H" ASSEMBLED ON WW 35, 2000 THIS IS A 30EPH06 LOT CODE 5657 WITH ASSEMBLY LOGO PART NUMBER YEAR 0 = 2000 P = LEAD-FREE WEEK 35 LINE H P035H 56 57 30EPH06 DATE CODE 15.90 (0.626) 15.30 (0.602) 14.20 (0.559) 14.80 (0.583) 3.70 (0.145) 4.30 (0.170) 5.30 (0.208) 5.70 (0.225) 5.50 (0.217) 4.50 (0.177) (2 PLCS.) 3.55 (0.139) 3.65 (0.144) 2.20 (0.087) MAX. 1.00 (0.039) 1.40 (0.056) 0.40 (0.213) 0.80 (0.032) 4.70 (0.185) 5.30 (0.209) 1.5 (0.059) 2.5 (0.098) 2.40 (0.095) MAX. 10.86 (0.427) 10.94 (0.430) 20.30 (0.800) 19.70 (0.775) 1 3 DIA. Conforms to JEDEC Outline TO-247 Dimensions in millimeters and (inches) Outline Table ANODE BASE COMMON CATHODE CATHODE Marking Information

7www.irf.com 30EPH06PbF Bulletin PD-20879 11/04 IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information 11/04 Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level and Lead-Free. Qualification Standards can be found on IR's Web site. Ordering Information Table

30 E P H 06 PbF

1 - Current Rating (30 = 30A) 2 - Circuit Configuration: E = Single Diode P = TO-247AC (Modified) 4 - H = HyperFast Recovery 5 - Voltage Rating (06 = 600V) 6 - y none = Standard Production y PbF = Lead-Free Tube Standard Pack Quantity : 25 pieces