DESCRIPTION
Hazardous Location VRS sensors are designed for use in locations where explosion-proof or intrinsically safe sensors are required. Passive VRS (Variable Reluctance Speed) Magnetic Speed sensors are simple, rugged devices that do not require an external voltage source for operation. A permanent magnet in the sensor establishes a fixed magnetic field. The approach and passing of a ferrous metal target near the sensor’s pole piece (sensing area) changes the flux of the magnetic field, dynamically changing its strength. This change in magnetic field strength induces a current into a coil winding which is attached to the output terminals. The output signal of a VRS sensor is an ac voltage that varies in amplitude and wave frequency as the speed of the monitored device changes, and is usually expressed in peak to peak voltage (Vp-p). One complete waveform (cycle) occurs as each target passes the sensor’s pole piece. If a standard gear were used as a target, this output signal would resemble a sine wave if viewed on an oscilloscope. Honeywell also offers VRS sensors for general purpose, high output, power output, high resolution and high temperature, as well as low-cost molded versions.
FEATURES
Direct conversion of actuator speed to output frequency Simple installation No moving parts Designed for use over a wide range of speeds Adaptable to a wide variety of configurations Customized VRS products for unique speed sensing
applications
Housing diameters: 3/4 in, 5/8 in Housing material/style: stainless steel threaded Terminations: MS3106 connector, preleaded Output voltages: 30 Vp-p to 60 Vp-p POTENTIAL APPLICATIONS Engine RPM (revolutions per minute) measurement on aircraft, automobiles, boats, buses, trucks and rail vehicles Motor RPM on oil and gas drilling equipment and machinery Motor RPM measurement on drills, grinders, lathes and automatic screw machines Process speed measurement on food, textile, paper, woodworking, printing, tobacco and pharmaceutical industry machinery Motor speed measurement of electrical generating equipment in grain elevators, sawmills and other potentially explosive environments Speed measurement of pumps, blowers, mixers, exhaust Gear speed measurement
2 www.honeywell.com/sensing 3/4 INCH EXPLOSION-PROOF SENSORS (All dimensions for reference only. mm/[in]) When properly installed using the explosion containment method, all 3070X and catalog listings on this page are certified for use in hazardous locations as follows: Class I, Groups A, B, C, D; Class II Groups E, F, G; Class III. These catalog listings have been tested to and meet the requirements of applicable U.S. and Canadian specifications for the locations described above. General Specifications Test Condition Specifications Parameter Characteristic Parameter Characteristic Parameter Characteristic Min. output voltage 60 Vp-p Inductance 115 mH max. Surface speed 25 m/s [1000 in/s] Coil resistance 191 Ohm to 280 Ohm Gear pitch range 12 DP (module 2.11) or coarser Gear 8 DP (module 3.17) Pole piece diameter 4,75 mm [0.187 in] Optimum actuator 8 DP (module 3.17) ferrous metal gear Air gap 0,127 mm [0.005 in] Min. surface speed 0,38 m/s [15 in/s] typ. Max. operating frequency 40 kHz typ. Load resistance 100 kOhm Operating temp. range -73 ºC to 93 ºC [-100 ºF to 200 ºF] Vibration Mil-Std 202F Method 204D Mounting thread 3/4-20 UNEF-2A Termination 18 AWG PVC-Insulated Leads Catalog Listing Thread Length (A) Weight 24,05 [1.00]
3000 MIN
[120.00] 31,75 [1.250]A BLIND END SHELL POLE PIECE 1/2-14 NPT 3070A 3070A35 45 mm [1.8 in] 88 mm [3.5 in] 294 g [10.5 oz] 322 g [11.5 oz]
Industrial VRS Magnetic Speed Sensors Honeywell Sensing and Control 3 5/8 INCH EXPLOSION-PROOF SENSORS (All dimensions for reference only. mm/[in]) When properly installed using the explosion containment method, the 3090X catalog listings on this page are certified for use in hazardous locations as follows: Class I, Groups A, B, C, D; Class II Groups E, F, G; Class III. These catalog listings have been tested to and meet the requirements of applicable U.S. and Canadian specifications for the locations described above. The catalog listings on this page conform to standards: II 3 G EEx nA II T6. General Specifications Test Condition Specifications Parameter Characteristic Parameter Characteristic Parameter Characteristic Min. output voltage 60 Vp-p Inductance 115 mH max. Surface speed 25 m/s [1000 in/s] Coil resistance 191 Ohm to 280 Ohm Gear pitch range 12 DP (module 2.11) or coarser Gear 8 DP (module 3.17) Pole piece diameter 4,75 mm [0.187 in] Optimum actuator 8 DP (module 3.17) ferrous metal gear Air gap 0,127 mm [0.005 in] Minimum surface speed 0,38 m/s [15 in/s] typ. Maximum operating frequency 40 kHz typ. Load resistance 100 kOhm Operating temp. range -73 ºC to 93 ºC [-100 ºF to 200 ºF] Vibration Mil-Std 202F Method 204D Mounting thread 5/8-20 UNF-2A Termination 18 AWG PVC-insulated leads Catalog Listing Thread Length (A) Weight 24,5 [1.00] [120.00] 31,75 [1.250]A BLIND END SHELL POLE PIECE 1/2-14 NPT 3090A 3090A35 45 mm [1.8 in] 88 mm [3.5 in] 280 g [9.0 oz] 366 g [10.0 oz]
4 www.honeywell.com/sensing 5/8 INCH (M16*) INTRINSICALLY SAFE VRS SENSORS (All dimensions for reference only. mm/[in]) *Contact Honeywell for availability of metric mounting thread versions. When properly installed using the intrinsic safety protection method connected per the control drawings on pages 6 and 7, catalog listings 3042A is intrinsically safe for hazardous locations as follows: Class I, Groups A, B, C, D. This product has been tested to and meets the requirements of applicable U.S. and Canadian specifications for the locations described above. General Specifications Test Condition Specifications Parameter Characteristic Parameter Characteristic Parameter Characteristic Min. output voltage 30 Vp-p Inductance 26 mH max. Surface speed 25 m/s [1000 in/s] Coil resistance 150 Ohm Gear pitch range 16 DP (module 1.58) or coarser Gear 8 DP (module 3.17) Pole piece diameter 3,9 mm [0.156 in] Optimum actuator 12 DP (module 3.17) ferrous metal gear Air gap 0,127 mm [0.005 in] Min. surface speed 0,38 m/s [15 in/s] typ. Max. operating frequency 40 kHz typ. Load resistance 100 kOhm Operating temp. range -55 ºC to 120 ºC [-67 ºF to 250 ºF] Vibration N/A Mounting thread 5/8-18 UNF-2A Termination MS3106 connector Catalog Listing Weight Ø18,29 [0.720] 0,76 [0.030] 28,12 [1.107] B A 8,0 [0.312] Ø13,84 [0.545] + - 36.5 [1.437]19,05 [0.750] 3042A 70 g [2.5 oz]
Industrial VRS Magnetic Speed Sensors Honeywell Sensing and Control 5 5/8 INCH (M16*) INTRINSICALLY SAFE VRS SENSORS (All dimensions for reference only. mm/[in]) *Contact Honeywell for availability of metric mounting thread versions. When properly installed using the intrinsic safety protection method connected per the control drawings on pages 6 and 7, catalog listing 3042H20 is intrinsically safe for hazardous locations as follows: Class I, Groups A, B, C, D; Class II Groups E, F, G; Class III. This product has been tested to and meets the requirements of applicable U.S. and Canadian specifications for the locations described above. General Specifications Test Condition Specifications Parameter Characteristic Parameter Characteristic Parameter Characteristic Min. output voltage 30 Vp-p Inductance 26 mH max. Surface speed 25 m/s [1000 in/s] Coil resistance 150 Ohm Gear pitch range 16 DP (module 1.58) or coarser Gear 8 DP (module 3.17) Pole piece diameter 3,9 mm [0.156 in] Optimum actuator 12 DP (module 3.17) ferrous metal gear Air gap 0,127 mm [0.005 in] Min. surface speed 0,38 m/s [15 in/s] typ. Max. operating frequency 40 kHz typ. Load resistance 100 kOhm Operating temp. range -55 ºC to 120 ºC [-67 ºF to 250 ºF] Vibration N/A Mounting thread 5/8-18 UNF-2A Termination 18 AWG PVC-insulated leads Catalog Listing Weight 25,4 [1.00] [120.00] 31,75 [1.250] [2.0] 0,51 [0.020] 1/2-14 NPT 3042AH20 140 g [5.0 oz]
6 www.honeywell.com/sensing CONTROL DRAWING FOR SINGLE CHANNEL BARRIERS Hazardous Location Non-hazardous Location Intrinsic Safety Barrier Speed Sensor HAZARDOUS LOCATIONS Catalog listing 3042H20: Class I, Groups A, B, C, D Class II, Groups E, F, G Class III Catalog listing 3042A: Class I, Groups A, B, C, D ENTITY PARAMETERS Vmax = 24 V, Imax = 35 mA, Li = 26 mH, Ci = 0 μF Any barrier (see General Notes) with entity parameters connected in accordance with barrier manufacturers instructions of: Vmax > Voc Ca > Ci + cable capacitance Imax > Isc La > Li + cable inductance SYSTEM PARAMETERS Any barrier (see General Notes) having one of the following specified parameters: Vmax Rmin Vmax Rmin Vmax Rmin 30 707 20 421 10 136 25 580 15 278 5 1 GENERAL NOTES 1. For jurisdictions requiring certification to the applicable Canadian standards, the barrier must be CSA Certified and the system must be installed in accordance with the Canadian Electrical Code Part 1. 2. For jurisdictions requiring certification to the applicable Occupational Safety and Health Administration (OSHA) standards, the barrier must be CSA NRTL or equivalent and the system must be installed in accordance with the National Electrical Code (NEC), article 504 or ANSI/NFPA 70. SENSOR GROUNDING Catalog listing 3042A: Sensor housing must be connected to intrinsically safe system ground during installation. Catalog listing 3042H20: Green wire must be connected to intrinsically safe system ground. Exia = Intrinsically Safe, Sécurité Intrinsèque
Industrial VRS Magnetic Speed Sensors Honeywell Sensing and Control 7 CONTROL DRAWING FOR DUAL CHANNEL BARRIERS Hazardous Location Non-hazardous Location Intrinsic Safety Barrier Speed Sensor Ground HAZARDOUS LOCATIONS Catalog listing 3042H20: Class I, Groups A, B, C, D Class II, Groups E, F, G Class III Catalog listing 3042A: Class I, Groups A, B, C, D ENTITY PARAMETERS Vmax = 24 V, Imax = 35 mA, Li = 26 mH, Ci = 0 μF Any barrier (see General Notes) with entity parameters connected in accordance with barrier manufacturers instructions of: Vmax > Voc Ca > Ci + cable capacitance Imax > Isc La > Li + cable inductance SYSTEM PARAMETERS Any barrier (see General Notes) having one of the following specified parameters: Vmax Rmin Vmax Rmin Vmax Rmin 30 1414 20 842 10 272 25 1160 15 556 5 2 GENERAL NOTES 1. For jurisdictions requiring certification to the applicable Canadian standards, the barrier must be CSA Certified and the system must be installed in accordance with the Canadian Electrical Code Part 1. 2. For jurisdictions requiring Certification to the applicable Occupational Safety and Health Administration (OSHA) standards, the barrier must be CSA NRTL or equivalent and the system must be installed in accordance with the National Electrical Code (NEC), article 504 or ANSI/NFPA 70. SENSOR GROUNDING Catalog listing 3042A: Sensor housing must be connected to intrinsically safe system ground during installation. Catalog listing 3042H20: Green wire must be connected to intrinsically safe system ground. Exia = Intrinsically Safe, Sécurité Intrinsèque
1985 Douglas Drive North
Golden Valley, MN 55422 www.honeywell.com 005879-2-EN March 2012 Copyright © 2012 Honeywell International Inc. All rights reserved. WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. WARNING MISUSE OF DOCUMENTATION The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: info.sc@honeywell.com Internet: www.honeywell.com/sensing Phone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax