3000-U330-01 AMKA | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 2
Technical content
Electronic Locking & Monitoring 3000 - U 3 30 - 0 X EMKA Beschlagteile GmbH & Co. KG Rev. 2025-07-29 / Roh Art-Nr. 3417 Index C Page 1 of 2 Einpunktverriegelung Diese Verriegelung dient als Universalverschluss für beliebige Gehäuse. Ein eingebauter Kontakt signalisiert den Türzustand. 3000-U330-01 Basic Version: Öffnung durch Einschalten der Energieversorgung; minimale Einschaltdauer 5 Sekunden 3000-U330-02 Basic delayed relock Version: Öffnung durch Einschalten der Energieversorgung. Die Verrieglung bleibt so lange geöffnet, bis die Energieversorgung wieder abgeschaltet wird; minimale Einschaltdauer 5 Sekunden 3000-U330-03 Energy store Version: Öffnung durch Abschalten der Energieversorgung. Vor einer erneuten Öffnung muss die Verriegelung mind. 30 Sekunden an der Energieversorgung angeschlossen sein 3000-U330-05 Energy store, delayed re-lock Version: Öffnung durch Abschalten der Energieversorgung. Die Verrieglung bleibt so lange geöffnet, bis die Energieversorgung wieder eingeschaltet wird. Vor einer erneuten Öffnung muss die Verriegelung mind. 30 Sekunden an der Energieversorgung angeschlossen sein 3000-U330-04 Battery backup Version: Öffnung durch Steuerimpuls; permanente Stromversorgung der Verriegelung erforderlich; Open Collector Ausgang für Statusüberwachung Technische Änderungen vorbehalten. Single Point Latch This latch is used as universal lock for all kinds of cabinets or shelters. A built-in contact indicates the door status. 3000-U330-01 Basic version: latch opens when power supply is switched on; minimum release time 5 seconds 3000-U330-02 Basic delayed re-lock version: latch opens when power supply is switched on and remains in open position until power supply is switched off again; minimum release time 5 seconds 3000-U330-03 Energy store version: latch opens by switching off power supply. Before reopening, the latch must be connected to the supply voltage for at least 30 seconds 3000-U330-05 Energy store, delayed re-lock version: latch opens when power supply is switched off and stays in open position until power is switched on again. Before reopening, the latch must be connected to the supply voltage for at least 30 seconds 3000-U330-04 Battery Backup: latch opens via control pulse; requires permanent power supply at the latch; open collector output for monitoring of lock status Subject to technical changes. Fig. 1: 3000-U330-xx RJ45 plug front side view Pin number of plug Basis, delayed re-lock, energy store Battery backup Color 2 - GND BN 3 contact GND YE 4 latch (-) GND GN 5 latch (+) IN RD 6 contact Out BK 7 - latch (+) OG
Electronic Locking & Monitoring 3000 - U 3 30 - 0 X EMKA Beschlagteile GmbH & Co. KG Rev. 2025-07-29 / Roh Art-Nr. 3417 Index C Page 2 of 2 Characteristics ⚫ Open collector output (Battery Backup only)……………max. 40 V DC, max. 200 mA Fig. 2: 3000-U330-xx – Dimensional drawings