2R-6-T6 YAGEO | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 6
Technical content
RoHS compliant & free Product specification– July 12, 2023 V.1
2R-6-T6 seriesGAS DISCHARGE TUBS Circuit Protection Gas Discharge Tube (GDT) Data Sheet
Features
■ Provide ultra-fast response to surge voltage from slow-rising surge of 100V/s to rapid-rising surge of 1KV/μs. ■ Stable breakdown voltage. ■ High insulation resistance. ■ Low capacitance (≤1.0pF) ■ High holdover voltage ■ Large absorbing transient current capability. ■ Micro-Gap Design ■ Size: 6.0mm*6.0mm ■ Storage and operating temperature: -40℃ ~+ 8 5℃ ■ Meets MSL level 1, per J-STD-020 ■ Safety certification: UL
Applications
■ Repeaters, Modems. ■ Telephone Interface, Line cards. ■ Data communication equipment. ■ Line test equipment Part Number Code Marking
2R-6-T6 seriesGAS DISCHARGE TUBS Circuit Protection Dimensions MT y p e Symbol Dimension (mm) Spec. Tolerance D 6.0 ±0.2 D1 6.0 ±0.2 T 6.0 ±0.2 B 0.5 ±0.2
Electrical Characteristics
Code100V/s 1000V/μs 8/20μs 10times 50Hz,1sec 10/1000μs 100A Test Voltage (GΩ) 1MHz (V) (V) (KA) (A) (times) DC(V) (pF) 2RP075M-6-T6 75±20% 650 20 10 300 50 1.0 1.0 2RP075-6 2RP090M-6-T6 90±20% 600 20 10 300 50 1.0 1.0 2RP090-6 2RM150M-6-T6 150±20% 750 10 5 300 100 1.0 1.0 2RM150-6 2RM230M-6-T6 230±20% 750 10 5 300 100 1.0 1.0 2RM230-6 2RM250M-6-T6 250±20% 800 10 5 300 100 1.0 1.0 2RM250-6 2RM300M-6-T6 300±20% 800 10 5 300 100 1.0 1.0 2RM300-6 2RM350M-6-T6 350±20% 850 10 5 300 100 1.0 1.0 2RM350-6 2RM400M-6-T6 400±20% 850 10 5 300 100 1.0 1.0 2RM400-6 2RM470M-6-T6 470±20% 850 10 5 300 100 1.0 1.0 2RM470-6 2RM600M-6-T6 600±20% 900 10 5 300 100 1.0 1.0 2RM600-6 Electrical Ratings Items Test Condition/Description Requirement DC Spark-over Voltage The voltage is measured with voltage ramp dv/dt=100V/s. To meet the specified value Maximum Impulse Spark-over Voltage The maximum impulse spark-over voltage is measured with voltage ramp dv/dt=1000V/μs. Impulse Discharge Current Maximum 8/20 μs surge current that can be applied between two electrodes, 5 positive and 5 negative surges, with 3 minutes interval time. 1.5 6.0 Recommended Pad Size B D T
2R-6-T6 seriesGAS DISCHARGE TUBS Circuit Protection Alternating Discharge Current Rated RMS value of AC current at 50Hz, 1 sec. for 10 times with interval time 3 min. Insulation Resistance The resistance of gas tube shall be measured between two electrodes. Capacitance The capacitance of gas tube shall be measured between two electrodes. Test frequency: 1MHz Recommended Soldering Conditions Reflow Soldering Recommended Conditions Profile Feature Pb-Free Assembly Average ramp-up rate (TL to TP)3 ℃/second max. Preheat -Temperature Min (TSm i n) -Temperature Max (TSm a x) - T i m e( m i nt om a x )( t s ) 150℃ 200℃ 60-180 seconds TSm a x to TL -Ramp-up Rate 3 ℃/second max. Time maintained above: -Temperature (TL) -Time (tL) 217℃ 60-150 seconds Peak Temperature (TP)2 6 0 ℃ Time within 5℃ of actual Peak Temperature (tP) 20-40 seconds Ramp-down Rate 6 ℃/second max. Time 25℃ to Peak Temperature 8 minutes max.
2R-6-T6 seriesGAS DISCHARGE TUBS Circuit Protection Packaging Tape Symbol Dimension (mm) Spec. Tolerance W1 6 . 0 0 ± 0 . 2 0 P0 4.00 ±0.10 P1 12.00 ±0.10 P2 2.00 ±0.10 D0 1.50 ±0.1 E1 . 7 5 ± 0 . 1 0 F7 . 5 0 ± 0 . 1 0 A0 6.30 ±0.10 B0 6.30 ±0.10 K0 6.30 ±0.10 t0 0.40 ±0.10 Reel D 330.00 ±1.00 d1 3 . 0 0 ± 0 . 5 0 L2 0 . 0 0 ± 0 . 5 0 t2 . 0 0 ± 0 . 2 0 Quantity: 800pcs
www.yageo.com Circuit Protection Components Product specification LEGAL DISCLAIMER YAGEO, its distributors and agents (collectively, “YAGEO”), hereby disclaims any and all liabilities for any errors, inaccuracies or incompleteness contained in any product related information, including but not limited to product specifications, datasheets, pictures and/or graphics. YAGEO may make changes, modifications and/or improvements t o product related information at any time and without notice. YAGEO makes no representation, warranty, and/or guarantee about the fitness of its products for any particular purpose or the continuing production of any of its products. To the maximum exten t permitted by law, YAGEO disclaims (i) any and all liability arising out of the application or use of any YAGEO product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied w arranties, including warranties of fitness for a particular purpose, non -infringement and merchantability. YAGEO products are designed for general purpose applications under normal operation and usage conditions. Please contact YAGEO for the application s listed below which require especially high reliability for the prevention of defects which might directly cause damage to the third party's life, body or property: Aerospace equipment (artificial satellite, rocket, etc.), Atomic energy -related equipment, Aviation equipment, Disaster prevention equipment, crime prevention equipment, Electric heating apparatus, burning equipment, Highly public information network equipment, data -processing equipment , Medical devices, Military equipment, Power generation co ntrol equipment, Safety equipment, Traffic signal equipment, Transportation equipment and Undersea equipment, or for any other application or use in which the failure of YAGEO products could result in personal injury or death, or serious property damage. P articularly YAGEO Corporation and its affiliates do not recommend the use of commercial or automotive grade products for high reliability applications or manned space flight. Information provided here is intended to indicate product specifications only. YAGEO reserves all the rights for revising this content without further notification, as long as products are unchanged. Any product change will be announced by PCN.