RoHS compliant & free Product specification– July 12, 2023 V.1
2R-5-UT5 seriesGAS DISCHARGE TUBS Circuit Protection www.yageo.com Jul. 12, 2023 V.1 Gas Discharge Tube (GDT) Data Sheet
Features
■ Provide ultra-fast response to surge voltage from slow-rising surge of 100V/s to rapid-rising surge of 1KV/μs. ■ Stable breakdown voltage. ■ High insulation resistance. ■ Low capacitance (≤1.0pF) ■ High holdover voltage ■ Large absorbing transient current capability. ■ Micro-Gap Design ■ Size: 5.4mm*5.0mm ■ Storage and operational temperature: -40℃ ~+ 8 5℃ ■ Meets MSL level 1, per J-STD-020 ■ Safety certification: UL
Applications
■ Repeaters, Modems. ■ Telephone Interface, Line cards. ■ Data communication equipment. ■ Line test equipment Part Number Code Marking XXX: Device Marking Code
2R-5-UT5 seriesGAS DISCHARGE TUBS Circuit Protection www.yageo.com Jul. 12, 2023 V.1 Dimensions MT y p e Symbol Dimension (mm) Spec. Tolerance D 5.4 ±0.2 T 5.0 ±0.2 B 0.5 ±0.2
Electrical Characteristics
Code100V/s 1000V/μs 8/20μs ±5times 50Hz,1sec Test Voltage (GΩ) 1MHz (V) (V) (KA) (A) DC(V) (pF) 2RM075M-5 UT5 75±20% 650 10.0 5.0 25 1.0 1.0 075 2RM090M-5 UT5 90±20% 700 10.0 5.0 50 1.0 1.0 090 2RM150M-5 UT5 150±20% 700 10.0 5.0 50 1.0 1.0 150 2RM230M-5 UT5 230±20% 750 10.0 5.0 100 1.0 1.0 230 2RM250M-5 UT5 250±20% 750 10.0 5.0 100 1.0 1.0 250 2RL300M-5 UT5 300±20% 800 5.0 5.0 100 1.0 1.0 300 2RL350M-5 UT5 350±20% 900 5.0 5.0 100 1.0 1.0 350 2RL400M-5 UT5 400±20% 1000 5.0 5.0 100 1.0 1.0 400 2RL470M-5 UT5 470±20% 1100 5.0 5.0 250 1.0 1.0 470 2RL600M-5 UT5 600±20% 1500 5.0 5.0 250 1.0 1.0 600 2RL800M-5 UT5 800±20% 1800 5.0 5.0 250 1.0 1.0 800 2RL1000M-5 UT5 1000±20% 2000 5.0 5.0 500 1.0 1.0 102 2RK1200M-5 UT5 1200±20% 2400 3.0 3.0 500 1.0 1.0 122 2RK1500M-5 UT5 1500±20% 2800 3.0 3.0 500 1.0 1.0 152 Notes:① Specific code by request. Electrical Ratings Items Test Condition/Description Requirement DC Spark-over Voltage The voltage is measured with voltage ramp dv/dt=100V/s. To meet the specified valueMaximum Impulse Spark-over Voltage The maximum impulse spark-over voltage is measured with voltage ramp dv/dt=1000V/μs.
2R-5-UT5 seriesGAS DISCHARGE TUBS Circuit Protection www.yageo.com Jul. 12, 2023 V.1 Impulse Discharge Current Maximum 8/20μs surge current that can be applied between two electrodes, 5 positive and 5 negative surges, with 3 minutes interval time. 0 100 Time Impulse Width 8µs 20µs Crest value Alternating Discharge Current Rated RMS value of AC current at 50Hz, 1 sec. for 10 times with interval t i m e3m i n . Insulation Resistance The resistance of gas tube shall be measured between two electrodes. Capacitance The capacitance of gas tube shall be measured between two electrodes. Test frequency: 1MHz Recommended Soldering Conditions Reflow Soldering
2R-5-UT5 seriesGAS DISCHARGE TUBS Circuit Protection www.yageo.com Jul. 12, 2023 V.1 Recommended Conditions Profile Feature Pb-Free Assembly Average ramp-up rate (TL to TP)3 ℃/second max. Preheat -Temperature Min (TSm i n) -Temperature Max (TSm a x) - T i m e( m i nt om a x )( t s ) 150℃ 200℃ 60-180 seconds TSm a xto TL -Ramp-up Rate 3 ℃/second max. Time maintained above: -Temperature (TL) -Time (tL) 217℃ 60-150 seconds Peak Temperature (TP) 260 ℃ Time within 5℃ of actual Peak Temperature (tP) 20-40 seconds Ramp-down Rate 6 ℃/second max. Time 25℃ to Peak Temperature 8 minutes max. Packaging Tape Symbol Dimension (mm) Spec. Tolerance W1 2 . 0 0 ± 0 . 2 0 P0 4.00 ±0.10 P1 2 . 0 0 ± 0 . 1 0 P1 2.00 ±0.10 D1 . 5 5 ± 0 . 1 E 1.75 ±0.10 F 5.50 ±0.10 A0 5.80 ±0.10 B0 5.40 ±0.10 K0 5.80 ±0.10 t0 . 5 0 ± 0 . 1 0 Reel D 330.00 ±1.00 d1 3 . 0 0 ± 0 . 5 0 L2 0 . 0 0 ± 0 . 5 0 t 2.00 ±0.20 Quantity: 800pcs
www.yageo.com Circuit Protection Components Product specification LEGAL DISCLAIMER YAGEO, its distributors and agents (collectively, “YAGEO”), hereby disclaims any and all liabilities for any errors, inaccuracies or incompleteness contained in any product related information, including but not limited to product specifications, datasheets, pictures and/or graphics. YAGEO may make changes, modifications and/or improvements t o product related information at any time and without notice. YAGEO makes no representation, warranty, and/or guarantee about the fitness of its products for any particular purpose or the continuing production of any of its products. To the maximum exten t permitted by law, YAGEO disclaims (i) any and all liability arising out of the application or use of any YAGEO product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied w arranties, including warranties of fitness for a particular purpose, non -infringement and merchantability. YAGEO products are designed for general purpose applications under normal operation and usage conditions. Please contact YAGEO for the application s listed below which require especially high reliability for the prevention of defects which might directly cause damage to the third party's life, body or property: Aerospace equipment (artificial satellite, rocket, etc.), Atomic energy -related equipment, Aviation equipment, Disaster prevention equipment, crime prevention equipment, Electric heating apparatus, burning equipment, Highly public information network equipment, data -processing equipment , Medical devices, Military equipment, Power generation co ntrol equipment, Safety equipment, Traffic signal equipment, Transportation equipment and Undersea equipment, or for any other application or use in which the failure of YAGEO products could result in personal injury or death, or serious property damage. P articularly YAGEO Corporation and its affiliates do not recommend the use of commercial or automotive grade products for high reliability applications or manned space flight. Information provided here is intended to indicate product specifications only. YAGEO reserves all the rights for revising this content without further notification, as long as products are unchanged. Any product change will be announced by PCN.