www.sensata.com Copyright © 2017 Sensata Technologies Inc. | 2AM/3AM/4AM/8AM SERIES Motor Protector Introduction Klixon® automatic motor protectors (AM series) are small, light weight and sensitive to temperature and current. The sealed steel cases will stand most dip and bake processes and can be mounted directly on motor windings for fast detection of temperature changes. Available in a range of temperature and current sensitivities, the 2AM is suitable for a wide variety of applications. Designed to be mounted on the windings of electric motors and transformers, the 2AM protects against overheating and electrical overloading, offering the highest standards of safety and long term reliability. The 2AM’s steel case is epoxy sealed and then insulated with a Mylar® sleeve allowing direct mounting on the windings. Robust construction and ability to withstand typical mechanical pressures make the 2AM ideal for installation during the manufacture of electric motors and transformers. Where necessary, additional sealing can be provided to prevent epoxy ingress with specialized impregnation processes. By adding a customized 3rd lead, the standard device becomes a dual circuit 4AM, ideal protection for dual voltage or dual speed applications. For higher horse power applications, the 3AM provides protection for fault conditions up to 60 Amps. With a range of anticipating heaters matching protector to motor from 6 to 60 Amps and operating temperatures from 90 to 150°C, the 2AM series provides unsurpassed design flexibility for motor and transformer applications. 2/3/4AM SPECIFICATIONS Application Range Robust Sealed Construction Flexibility 2AM - 4AM 8AM

www.sensata.com Page 2 Copyright © 2017 Sensata Technologies Inc.

  • Split-Phase Motors · Ballast Protection · Transformers · Automotive Motors
  • Solenoids Typical Applications
  • Compact, Easy to Install · Individually temperature calibrated and checked
  • Positive make-and-break with Klixon® snapaction disc
  • Gasketed steel case suitable for many impregnation processes
  • Current and temperature sensitivity for maximum design flexibility
  • Specially designed terminals for easy addition of wireleads. Reasons to use the 8AM Protector in your Product Designed specifically for motors with a fast rate of temperature rise (25-35°C/sec), the 8AM provides economical protection for a full range of motors and transformers ranging from washing machines to vacuum cleaners; computer disk drives to high capacity automotive motors. This unique design is capable of providing all mode protection:
  • Locked Rotor · Running Overload · Low Voltage · Run Both Winding 8AM SPECIFICATIONS Introduction Dimensions in mm (Inches) DIMENSIONS AND DIAGRAMS

www.sensata.com Page 3 Copyright © 2017 Sensata Technologies Inc. 2AM Series

www.sensata.com Page 4 Copyright © 2017 Sensata Technologies Inc. 8AM Series Breakdown

www.sensata.com Page 5 Copyright © 2017 Sensata Technologies Inc. ORDERING OPTIONS Example : 2AM7BSH0500-140 Example : 8AM2GVHA10-120 Device Device 2/3/4AM Series 8AM Series Disc Thickness Contact Capacity Disc Material Opening Temp. Heater Closing Temp. Wire Leads and Terminations 2AM 8AM V G S V 0500 A H H 140 10 120 Disc Thickness Disc Material Opening Temp. Heater Closing Temp. Wire Leads and Terminations

www.sensata.comCopyright © 2018 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. CONTACT US Revised 08/15/18 Americas +1 (508) 236-2551 electrical-protection-sales@ sensata.com Europe, Middle East & Africa +31743578156 info-sse@list.sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 120V 240V UL CSA CNR ENEC 2AM 3AM 4AM Standard 547 Guide No. 400-H13-C File E15962 File LR2341C Guide No. 184-N-13.90 Class 3211 Standard EN60730-2-2 File 2014531-19 8AM1 8AM2 8AM3 Standard UL2111 Standard C22.2 No 77 Standard EN60730-2-2 File 2014531-08 VOLTAGE RATINGS, AGENCY APPROVALS, & CERTIFICATIONS