BLF 3.50/06/180 SN OR BX LRP Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Product image simillar to illustration Connect efficiently - in a small space: female header with spring connection (PUSH IN) as a plug-in connection level; used together with male headers in 3.50 mm pitch. General ordering data Version PCB plug-in connector, female plug, 3.50 mm, Number of poles: 6, 180°, PUSH IN with actuator, Clamping range, max. : 1.5 mm², Box Order No. 2960070000 Type BLF 3.50/06/180 SN OR BX LRP GTIN (EAN) 4099986751569 Qty. 84 items Product data IEC: 320 V / 17.5 A / 0.14 - 1.5 mm² UL: 300 V / 10 A / AWG 26 - AWG 16 Packaging Box Creation date 28.02.2026 02:03:42 MEZ Catalogue status / Drawings 1

BLF 3.50/06/180 SN OR BX LRP Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Technical data Approvals Approvals UL File Number Search UL Website Certificate No. (cURus) E60693 Dimensions and weights Depth 22.7 mm Depth (inches) 0.8937 inch Height 9 mm Height (inches) 0.3543 inch Width 17.5 mm Width (inches) 0.689 inch Net weight 4.2 g Environmental Product Compliance RoHS Compliance Status Compliant without exemption REACH SVHC No SVHC above 0.1 wt% Product Carbon Footprint Cradle to gate 0,923 kg CO2 eq. System Parameters Product family OMNIMATE Signal - series BL/SL 3.50 Type of connection Field connection Wire connection method PUSH IN with actuator Pitch in mm (P) 3.50 mm Pitch in inches (P) 0.138 " Conductor outlet direction 180° Number of poles 6 L1 in mm 17.50 mm L1 in inches 0.689 " Number of rows 1 Pin series quantity 1 Rated cross-section 1.5 mm² Touch-safe protection acc. to DIN VDE 57 106 Safe from finger touch Touch-safe protection acc. to DIN VDE 0470 IP20 plugged/ IP10 unplugged Protection degree IP20, when fully mounted Volume resistance ≤5 mΩ Stripping length 8 mm Stripping length tolerance min. 0 mm max. 1 mm Screwdriver blade 0.4 x 2.5 Screwdriver blade standard DIN 5264-A Plugging cycles 25 Plugging force/pole, max. 6 N Pulling force/pole, max. 6 N Material data Insulating material PA GF Colour orange Colour chart (similar) RAL 2000 Insulating material group II Comparative Tracking Index (CTI) ≥ 400, ≤ 600 Moisture Level (MSL) UL 94 flammability rating V-0 Contact material Cu-alloy Creation date 28.02.2026 02:03:42 MEZ Catalogue status / Drawings 2

BLF 3.50/06/180 SN OR BX LRP Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Technical data Contact surface tinned Storage temperature, min. -40 °C Storage temperature, max. 70 °C Operating temperature, min. -50 °C Operating temperature, max. 120 °C Temperature range, installation, min. -30 °C Temperature range, installation, max. 100 °C Conductors suitable for connection Clamping range, min. 0.14 mm² Clamping range, max. 1.5 mm² Wire connection cross section AWG, min. AWG 26 Wire connection cross section AWG, max. AWG 16 Solid, min. H05(07) V-U 0.14 mm² Solid, max. H05(07) V-U 1.5 mm² Flexible, min. H05(07) V-K 0.14 mm² Flexible, max. H05(07) V-K 1.5 mm² w. plastic collar ferrule, DIN 46228 pt 4, min. 0.28 mm² w. plastic collar ferrule, DIN 46228 pt 4, max. 1 mm² w. wire end ferrule, DIN 46228 pt 1, min. 0.25 mm² w. wire end ferrule, DIN 46228 pt 1, max. 1 mm² Plug gauge in accordance with EN 60999 a x b; ø 2.4 mm x 1.5 mm Clampable conductor Cross-section for conductor connection Type fine-wired nominal 0.25 mm² wire end ferrule Stripping length nominal 10 mm Recommended wire- end ferrule H0,25/12 HBL Cross-section for conductor connection Type fine-wired nominal 0.34 mm² wire end ferrule Stripping length nominal 10 mm Recommended wire- end ferrule H0,34/12 TK Cross-section for conductor connection Type fine-wired nominal 0.5 mm² wire end ferrule Stripping length nominal 10 mm Recommended wire- end ferrule H0,5/14 OR Cross-section for conductor connection Type fine-wired nominal 0.75 mm² wire end ferrule Stripping length nominal 10 mm Recommended wire- end ferrule H0,75/14T HBL Cross-section for conductor connection Type fine-wired nominal 1 mm² wire end ferrule Stripping length nominal 10 mm Recommended wire- end ferrule H1,0/14 GE Reference text The outside diameter of the plastic collar should not be larger than the pitch (P), Length of ferrules is to be chosen depending on the product and the rated voltage. Creation date 28.02.2026 02:03:42 MEZ Catalogue status / Drawings 3

BLF 3.50/06/180 SN OR BX LRP Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Technical data Rated data acc. to IEC tested acc. to standard IEC 60664-1, IEC 61984 Rated current, min. number of poles (Tu=20°C) 17.5 A Rated current, max. number of poles (Tu=20°C) 14.7 A Rated current, min. number of poles (Tu=40°C) 17.1 A Rated current, max. number of poles (Tu=40°C)

13.1 A Rated voltage for surge voltage class /

Rated voltage for surge voltage class / pollution degree III/2

160 V Rated voltage for surge voltage class /

Rated impulse voltage for surge voltage class/ pollution degree II/2 2.5 kV Rated impulse voltage for surge voltage class/ pollution degree III/2 2.5 kV Rated impulse voltage for surge voltage class/ contamination degree III/3 2.5 kV Short-time withstand current resistance 1 x 1s with 120 A Rated data acc. to CSA Rated voltage (Use group B / CSA) 300 V Rated voltage (Use group C / CSA) 50 V Rated voltage (Use group D / CSA) 300 V Rated current (Use group B / CSA) 10 A Rated current (Use group D / CSA) 10 A Wire cross-section, AWG, min. AWG 16 Wire cross-section, AWG, max. AWG 26 Rated data acc. to UL 1059 Institute (cURus) CURUS Certificate No. (cURus) E60693 Rated voltage (Use group B / UL 1059) 300 V Rated voltage (Use group C / UL 1059) 50 V Rated voltage (Use group D / UL 1059) 300 V Rated current (Use group B / UL 1059) 10 A Rated current (Use group D / UL 1059) 10 A Wire cross-section, AWG, min. AWG 26 Wire cross-section, AWG, max. AWG 16 Reference to approval values Specifications are maximum values, details - see approval certificate. Packing Packaging Box VPE length 0.00 VPE width 0.00 VPE height 0.00 Type tests Visual and dimensional test Standard IEC 60512-1-1:2002-02 Test dimensional inspection Evaluation passed Standard IEC 60512-1-2:2002-02 Test weight check Evaluation passed Standard IEC 61984:2001-10 section 6.2 Test visual examination Evaluation passed Test: Durability of markings Standard IEC 60068-2-70:1995-12 test Xb Test mark of origin, type identification, pitch, type of material, date clock, approval marking UL, approval marking CSA, durability Evaluation available Test: Misengagement (Non- interchangeability) Standard IEC 60512-13-5:2006-02 Test intentional plugging Evaluation passed Test 180° turned without coding elements Evaluation passed Test 180° turned with coding elements Creation date 28.02.2026 02:03:42 MEZ Catalogue status / Drawings 4

BLF 3.50/06/180 SN OR BX LRP Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Technical data Evaluation passed Test visual examination Evaluation passed Test: Clampable cross section Standard IEC 60999-1:1999-11 section 9.1, IEC 60947-1:2011-03 section 8.2.4.5.1 Conductor type Type of conductor and conductor cross- section solid 0.14 mm² Type of conductor and conductor cross- section stranded 0.14 mm² Type of conductor and conductor cross- section solid 1.5 mm² Type of conductor and conductor cross- section stranded 1.5 mm² Type of conductor and conductor cross- section AWG 26/1 Type of conductor and conductor cross- section AWG 26/19 Type of conductor and conductor cross- section AWG 16/1 Type of conductor and conductor cross- section AWG 16/19 Evaluation passed Test for damage to and accidental loosening of conductors Standard IEC 60999-1:1999-11 section 9.4 bzw. section 8.10 Requirement 0.3 kg Conductor type Type of conductor and conductor cross- section H05V-U0.5 Type of conductor and conductor cross- section H05V-K0.5 Evaluation passed Requirement 0.4 kg Conductor type Type of conductor and conductor cross- section H07V-U1.5 Type of conductor and conductor cross- section H07V-K1.5 Type of conductor and conductor cross- section AWG 16/1 Type of conductor and conductor cross- section AWG 16/19 Evaluation passed Requirement 0.2 kg Conductor type Type of conductor and conductor cross- section AWG 26/1 Type of conductor and conductor cross- section AWG 26/19 Evaluation passed Pull-out test Standard IEC 60999-1:1999-11 section 9.5 Creation date 28.02.2026 02:03:42 MEZ Catalogue status / Drawings 5

BLF 3.50/06/180 SN OR BX LRP Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Technical data Requirement ≥20 N Conductor type Type of conductor and conductor cross- section H05V-U0.5 Type of conductor and conductor cross- section H05V-K0.5 Evaluation passed Requirement ≥40 N Conductor type Type of conductor and conductor cross- section H07V-U1.5 Type of conductor and conductor cross- section H07V-K1.5 Type of conductor and conductor cross- section AWG 16/1 Type of conductor and conductor cross- section AWG 16/19 Evaluation passed Requirement ≥10 N Conductor type Type of conductor and conductor cross- section AWG 26/1 Type of conductor and conductor cross- section AWG 26/19 Evaluation passed Important note IPC conformity Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 "Class 2". Further claims on the products can be evaluated on request. Notes • Additional variants on request

  • Gold-plated contact surfaces on request
  • Rated current related to rated cross-section & min. No. of poles.
  • Wire end ferrule without plastic collar to DIN 46228/1
  • Wire end ferrule with plastic collar to DIN 46228/4
  • P on drawing = pitch
  • Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards.
  • The test point can only be used as potential-pickup point.
  • In accordance with IEC 61984, OMNIMATE-connectors are connectors without breaking capacity (COC). During designated use, connectors are not allowed to be engaged or disengaged when live or under load
  • Long term storage of the product with average temperature of 50 °C and maximum humidity 70%, 36 months Classifications ETIM 8.0 EC002638 ETIM 9.0 EC002638 ETIM 10.0 EC002638 ECLASS 14.0 27-46-02-02 ECLASS 15.0 27-46-02-02 Creation date 28.02.2026 02:03:42 MEZ Catalogue status / Drawings 6

BLF 3.50/06/180 SN OR BX LRP Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Drawings Dimensional drawing Derating curve Derating curve Product benefits Solid PUSH IN contactSafe and durable Creation date 28.02.2026 02:03:42 MEZ Catalogue status / Drawings 7