waterpurification.pentair.com FLECK 2850 CONTROL VALVE SERVICE MANUAL

2 • FLECK 2850 Control Valve Service Manual TABLE OF CONTENTS 3200, 3210, 3220, 3230 REGENERATION CYCLE

1600 SERVICE VALVE OPERATOR ASSEMBLY

  1. Type of Timer: A. 7 Day or 12 Day B. Meter Initiated 2. Downflow: Upflow Upflow Variable 3. Meter Size: A. 3/4-inch Std Range (125 - 2,100 gallon setting) B. 3/4-inch Ext Range (625 - 10,625 gallon setting) C. 1-inch Std Range (310 - 5,270 gallon setting) D. 1-inch Ext Range (1,150 - 26,350 gallon setting) E. 1-1/2 inch Std Range (625 - 10,625 gallon setting) F. 1-1/2 inch Ext Range (3,125 - 53,125 gallon setting) G. 2-inch Std Range (1,250 - 21,250 gallon setting) H. 2-inch Ext Range (6,250 - 106,250 gallon setting) I. 3-inch Std Range (3,750 - 63,750 gallon setting) J. 3-inch Ext Range (18,750 - 318,750 gallon setting) 4. System Type: A. System #4: 1 Tank, 1 Meter, Immediate, or Delayed Regeneration B. System #4: Time Clock C. System #4: Twin Tank D. System #5: 2-5 Tanks, Interlock Mechanical 2-4 Tanks, Interlock Electronic Meter per unit for Mechanical and Electronic E. System #6: 2-5 Tanks, 1 Meter, Series Regeneration, Mechanical 2-4 Tanks, 1 Meter, Series Regeneration, Electronic F. System #7: 2-5 Tanks, 1 Meter, Alternating Regeneration,Mechanical

2 Tanks only, 1 Meter, Alternating

Regeneration, Electronic G. System #9: Electronic Only, 2-4 Tanks, Meter per Valve, Alternating H. System #14: Electronic Only, 2-4 Tanks, Meter per Valve. Brings units on and offline based on flow. 5. Timer Program Settings: 6. Drain Line Flow Control: gpm 7. Brine Line Flow Controller: gpm 8. Injector Size#: 9. Piston Type: A. Hard Water Bypass B. No Hard Water Bypass CALIFORNIA PROPOSITION 65 WARNING WARNING: This product contains chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.

FLECK 2850 Control Valve Service Manual • 3 INSTALLATION Water Pressure A minimum of 20 pounds (1.4 bar) of water pressure is required for regeneration valve to operate effectively. Electrical Facilities An uninterrupted alternating current (A/C) supply is required. NOTE: Other voltages are available. Please make sure your voltage supply is compatible with your unit before installation. Existing Plumbing Condition of existing plumbing should be free from lime and iron buildup. Piping that is built up heavily with lime and/ or iron should be replaced. If piping is clogged with iron, a separate iron filter unit should be installed ahead of the water softener. Location Of Softener And Drain The softener should be located close to a drain to prevent air breaks and back flow. Bypass Valves Always provide for the installation of a bypass valve if unit is not equipped with one. CAUTION Water pressure is not to exceed 125 psi (8.6 bar), water temperature is not to exceed 110°F (43°C), and the unit cannot be subjected to freezing conditions. Installation Instructions 1. Place the softener tank where you want to install the unit making sure the unit is level and on a firm base. 2. During cold weather, the installer should warm the valve to room temperature before operating. 3. All plumbing should be done in accordance with local plumbing codes. The pipe size for residential drain line should be a minimum of 1/2-inch (13 mm). Backwash flow rates in excess of 7 gpm (26.5 Lpm) or length in excess of 20 feet (6 m) require 3/4-inch (19 mm) drain line. Commercial drain lines should be the same size as the drain line flow control. 4. Refer to the dimensional drawing for cutting height of the distributor tube. If there is no dimensional drawing, cut the distributor tube flush with the top of the tank. 5. Lubricate the distributor o-ring seal and tank o-ring seal. Place the main control valve on tank. NOTE: Only use silicone lubricant. IMPORTANT: For valves equipped with electromechanical timers and stainless steel meters, refer to the Meter Dome and Union Orientation section. 7. Solder joints near the drain must be done prior to connecting the Drain Line Flow Control fitting (DLFC). Leave at least 6 inches (15 cm) between the DLFC and solder joints when soldering pipes that are connected on the DLFC. Failure to do this could cause interior damage to the DLFC. 8. Plumber tape is the only sealant to be used on the drain fitting. The drain from twin tank units may be run through a common line. 9. Make sure that the floor is clean beneath the salt storage tank and that it is level. 10. Place approximately 1 inch (25 mm) of water above the grid plate. If a grid is not utilized, fill to the top of the air check (Figure 1) in the salt tank. Do not add salt to the brine tank at this time. 11. On units with a by-pass, place in by-pass position. Turn on the main water supply. Open a cold soft water tap nearby and let run a few minutes or until the system is free from foreign material (usually solder) that may have resulted from the installation. Once clean, close the water tap. 12. Slowly place the by-pass in service position and let water flow into the mineral tank. When water flow stops, slowly open a cold water tap nearby and let run until the air is purged from the unit. 13. Plug unit into an electrical outlet. NOTE: All electrical connections must be connected according to local codes. Be certain the outlet is uninterrupted.

60002 Rev E

4 • FLECK 2850 Control Valve Service Manual START-UP INSTRUCTIONS The water softener should be installed with the inlet, outlet, and drain connections made in accordance with the manufacturer’s recommendations, and to meet applicable plumbing codes. 1. Turn the manual regeneraton knob slowly in a clockwise direction until the program micro switch lifts on top of the first set of pins. Allow the drive motor to move the piston to the first regeneration step and stop. Each time the program switch position changes, the valve will advance to the next regeneration step. Always allow the motor to stop before moving to the next set of pins or spaces. NOTE: For electronic valves, please refer to the manual regeneration part of the timer operation section. If the valve came with a separate electronic timer service manual, refer to the timer operation section of the electronic timer service manual. 2. Position the valve to backwash. Ensure the drain line flow remains steady for 10 minutes or until the water runs clear (see above). 3. Position the valve to the brine / slow rinse position. Ensure the unit is drawing water from the brine tank (this step may need to be repeated). 4. Position the valve to the rapid rinse position. Check the drain line flow, and run for 5 minutes or until the water runs clear. 5. Position the valve to the start of the brine tank fill cycle. Ensure water goes into the brine tank at the desired rate. The brine valve drive cam will hold the valve in this position to fill the brine tank for the first regeneration. 6. Replace control box cover. 7. Put salt in the brine tank. NOTE: Do not use granulated or rock salt.

3200 TIMER SETTING PROCEDURE

How To Set Days On Which Water Conditioner Is To Regenerate (Figure 5) Rotate the skipper wheel until the number “1” is at the red pointer. Set the days that regeneration is to occur by sliding tabs on the skipper wheel outward to expose trip fingers. Each tab is one day. Finger at red pointer is tonight. Moving clockwise from the red pointer, extend or retract fingers to obtain the desired regeneration schedule. How To Set The Time Of Day 1. Press and hold the red button in to disengage the drive gear. 2. Turn the large gear until the actual time of day is at the time of day pointer. 3. Release the red button to again engage the drive gear. How To Manually Regenerate Your Water Conditioner At Any Time 1. Turn the manual regeneration knob clockwise. 2. This slight movement of the manual regeneration knob engages the program wheel and starts the regeneration program. 3. The black center knob will make one revolution in the following approximately three hours and stop in the position shown in the drawing. 4. Even though it takes three hours for this center knob to complete one revolution, the regeneration cycle of your unit might be set for only one half of this time. INSTALLATION CONTINUED Meter Dome and Union Orientation Control valves outfitted with an electromechanical timer and stainless steel water meter include a special male x female threaded stainless steel union to insure proper installation and operation of the water meter. The location of this union in relation to the control valve and water meter is critical for proper operation. DO NOT omit or substitute this special union; it positions the meter dome at the correct distance from the control valve and allows re-positioning the water meter dome for proper operation. 1. Apply a suitable thread sealant to the male threads of the union and meter body. 2. Thread the union into the OUTLET port of the control valve, then thread the meter into the union. See illustrations below. 3. Rotate the water meter body so the meter dome is at the 12 o’clock position. Loosen the nut on the union to facilitate this if required. Once in position, tighten the union nut. 4. Connect the meter cable to the open port in the center of the meter dome. 5. Continue with the installation of the control valve. Position Meter Dome at 12 o’clock orientation Meter Union Valve Body Powerhead Assembly

FLECK 2850 Control Valve Service Manual • 5 5. In any event, conditioned water may be drawn after rinse water stops flowing from the water conditioner drain line. How to Adjust Regeneration Time 1. Disconnect the power source. 2. Locate the three screws behind the manual regeneration knob by pushing the red button in and rotating the 24 hour dial until each screw appears in the cut out portion of the manual regeneration knob. 3. Loosen each screw slightly to release the pressure on the time plate from the 24-hour gear. 4. Locate the regeneration time pointer on the inside of the 24 hour dial in the cut out. 5. Turn the time plate so the desired regeneration time aligns next to the raised arrow. 6. Push the red button in and rotate the 24 hour dial. Tighten each of the three screws. 7. Push the red button and locate the pointer one more time to ensure the desired regeneration time is correct. 8. Reset the time of day and restore power to the unit. 61502-3200 Rev A Figure 5

3210 TIMER SETTING PROCEDURE

Typical Programming Procedure Calculate the gallon capacity of the system, subtract the necessary reserve requirement and set the gallons available opposite the small white dot on the program wheel gear (Figure 6). NOTE: Drawing shows 8,750 gallon setting. The capacity (gallons) arrow (15) shows zero gallons remaining. The unit will regenerate tonight at the set regeneration time. How To Set The Time Of Day 1. Press and hold the red button in to disengage the drive gear. 2. Turn the large gear until the actual time of day is opposite the time of day pointer. 3. Release the red button to again engage the drive gear. How To Manually Regenerate Your Water Conditioner At Any Time 1. Turn the manual regeneration knob clockwise. 2. This slight movement of the manual regeneration knob engages the program wheel and starts the regeneration program. 3. The black center knob will make one revolution in the following approximately three hours and stop in the position shown in the drawing. 4. Even though it takes three hours for this center knob to complete one revolution, the regeneration cycle of your unit might be set for only one half of this time. 5. In any event, conditioned water may be drawn after rinse water stops flowing from the water conditioner drain line. Immediate Regeneration Timers These timers do not have a 24 hour gear. Setting the gallons on the program wheel and manual regeneration procedure are the same as previous instructions. The timer will regenerate as soon as the capacity gallons reaches zero. NOTE: The program wheel to the left may be different than the program wheel on the product. NOTE: To set meter capacity rotate manual knob one - 360° revolution to set gallonage. 61502-3200 Rev A Figure 6 STARTUP INSTRUCTIONS CONTINUED

6 • FLECK 2850 Control Valve Service Manual 3200, 3210, 3220, 3230 REGENERATION CYCLE SETTING PROCEDURE How To Set The Regeneration Cycle Program The regeneration cycle program on your water conditioner has been factory preset, however, portions of the cycle or program may be lengthened or shortened in time to suit local conditions.

3200 Series Timers (Figure 7)

  1. To expose cycle program wheel, grasp timer in upper left-hand corner and pull, releasing snap retainer and swinging timer to the right. 2. To change the regeneration cycle program, the program wheel must be removed. Grasp program wheel and squeeze protruding lugs toward center, lift program wheel off timer. Switch arms may require movement to facilitate removal. 3. Return timer to closed position engaging snap retainer in back plate. Make certain all electrical wires locate above snap retainer post. Timer Setting Procedure How To Change The Length Of The Backwash Time The program wheel as shown in the drawing is in the service position. As you look at the numbered side of the program wheel, the group of pins starting at zero determines the length of time your unit will backwash. For example, if there are six pins in this section, the time of backwash will be 12 min. (2 min. per pin). To change the length of backwash time, add or remove pins as required. The number of pins times two equals the backwash time in minutes. How To Change The Length Of Brine And Rinse Time 1. The group of holes between the last pin in the backwash section and the second group of pins determines the length of time that your unit will brine and rinse (2 min. per hole). 2. To change the length of brine and rinse time, move the rapid rinse group of pins to give more or fewer holes in the brine and rinse section. Number of holes times two equals brine and rinse time in minutes. How To Change The Length Of Rapid Rinse 1. The second group of pins on the program wheel determines the length of time that your water conditioner will rapid rinse (2 min. per pin). 2. To change the length of rapid rinse time, add or remove pins at the higher numbered end of this section as required. The number of pins times two equals the rapid rinse time in minutes. How To Change The Length Of Brine Tank Refill Time 1. The second group of holes in the program wheel determines the length of time that your water conditioner will refill the brine tank (2 min. per hole). 2. To change the length of refill time, move the two pins at the end of the second group of holes as required. 3. The regeneration cycle is complete when the outer microswitch is tripped by the two pin set at end of the brine tank refill section. 4. The program wheel, however, will continue to rotate until the inner micro switch drops into the notch on the program wheel. 61502-3210 Rev A Figure 7

FLECK 2850 Control Valve Service Manual • 7 [ THIS PAGE LEFT INTENTIONALLY BLANK ]

8 • FLECK 2850 Control Valve Service Manual

615023200 Rev A

3200 TIME CLOCK TIMER ASSEMBLY

FLECK 2850 Control Valve Service Manual • 9 Item No. QTY Part No. Description 4-40 x 1-1/8 RPM RPM RPM RPM 6-32 x .156 Timer Black inches Timer Assembly Auxiliary, Optional Filter 2 Min Per Pin Softener, 2 Min Per Pin Soft Immed, 2 Min Per Pin Filter Immed, 2 Min Per Pin *Call your distributor for Part Number Item No. QTY Part No. Description

10 • FLECK 2850 Control Valve Service Manual

3210 METER DELAYED TIMER ASSEMBLY

FLECK 2850 Control Valve Service Manual • 11 Item No. QTY Part No. Description Black 6-20 x 1/2 1/30 RPM RPM 1/30 RPM 1/30 RPM 6-32 x .156 Drive 4-40 x 1 1/8 Timer Delayed Timer Assembly STD Label 0-2,100 gal EXT Label 0-10,000 gal STD Metric Label 0-8 m3 EXT Range 0-40 m3 STD Range Label, 0-10,500 EXT Range Label, 0-50,000 3, STD Range 1-1/2 inch Meter Label Auxiliary, Optional Filter 2 Min Per Pin Softener, 2 Min Per Pin Soft Immed, 2 Min Per Pin Filter Immed, 2 Min Per Pin *Call your distributor for Part Number Item No. QTY Part No. Description

12 • FLECK 2850 Control Valve Service Manual

3220 METER IMMEDIATE TIMER

FLECK 2850 Control Valve Service Manual • 13 Item No. QTY Part No. Description System #5 6-20 x 1/2 6-20 x 1/2 1/30 RPM 1/30 RPM 1/30 RPM 1/30 RPM 1/30 RPM 1/30 RPM 4-40 x 1-1/8 Item No. QTY Part No. Description Stainless Steel, Timer Immediate Timer Assy STD Label 0-2,100 gal EXT Label 0-10,000 gal STD Metric Label 0-8 m EXT Range 0-40 m STD Range Label, 0-10,500 EXT Range Label, 0-50,000 3, STD Range 1-1/2 inch Meter Label Auxiliary, Optional Filter 2 Min Per Pin Softener, 2 Min Per Pin Softener Immediate 2 Min Per Pin Filter Immediate 2 Min Per Pin *Call your distributor for Part Number*Call your distributor for Part Number

14 • FLECK 2850 Control Valve Service Manual

3230 REMOTE START TIMER ASSEMBLY

FLECK 2850 Control Valve Service Manual • 15 Item No. QTY Part No. Description 4-40 x 1-1/8 1/30 RPM 1/30 RPM 1/30 RPM 3200 Stainless Steel, Timer Auxiliary, Optional Softener Immediate 2 Min Per Pin Filter Immediate 2 Min Per Pin *Call your distributor for Part Number Item No. QTY Part No. Description

16 • FLECK 2850 Control Valve Service Manual POWERHEAD ASSEMBLY (DESIGNER) 61502_2510 Rev B 18A

FLECK 2850 Control Valve Service Manual • 17 Item No. QTY Part No. Description Valve Operator, W-T- Screws America Environmental 50/60Hz Separate Time Fill (Black) Optional Not Shown: 1-1/2 inch Brass Meter 1-1/2 inch Stainless Steel Meter * Bracket is integrated into the motor. Bracket is integrated into the motor and picture may not reflect actual component. *Call your distributor for Part Number Motor drawing may not resemble actual. For Service Assembly Numbers, See the Back of this Manual Item No. QTY Part No. Description POWERHEAD ASSEMBLY (DESIGNER) CONTINUED

18 • FLECK 2850 Control Valve Service Manual BR61501-1500 Rev C POWERHEAD ASSEMBLY (ENVIRONMENTAL) 1619 11A 8

FLECK 2850 Control Valve Service Manual • 19 Item No. QTY Part No. Description American, Flat Austrailian Japanese European Envirmtl 1/2 35 in-lbs ±20% 2900 x 1 5.0 in-lbs ±10% 50-60Hz, SP, Fam 1 50-60 Hz, Fam 1 8 x 3/8 20 in-lbs ±20%

12 Day

(Used on Filter Valves) FIlter Valves) Wrench Tighten 20 in-lbs ±20% 5/16 Hand Tighten Black, Clear Window Black, Black Window 50-60 Hz FAM 1 Hz SP FAM1 Motor Not Shown: 1-1/2 inch Brass Meter 1-1/2 inch Stainless Steel Meter *Call your distributor for Part Number Item No. QTY Part No. Description POWERHEAD ASSEMBLY (ENVIRONMENTAL) CONTINUED

20 • FLECK 2850 Control Valve Service Manual MANUAL POWERHEAD ASSEMBLY Item No. QTY Part No. Description 1/4 - 20 x 1/2 Screw, Zinc 1/2 18-8 SS Softener x 3/8 Type “B” RC44-47 Not Shown:

60409 Rev A

FLECK 2850 Control Valve Service Manual • 21 CONTROL VALVE WITH 1700 INJECTOR ASSEMBLY 61500-2850 REV D 26 25 OPTIONAL

22 • FLECK 2850 Control Valve Service Manual Item No. QTY Part No. Description Water 1/4 - 20x1 NHWBP O-ring Flange Rotating Cap 18-8 N-SERS Water Converstion, NHWBP Assy, NHWBP, Replacement Assy, NHWBP, 1600 Assy, NHWBP, 1700 Used for Cold and Hot Water Plastic Spacers Plastic Spacers, 559 PE Seals 2850, 2900 NPT 2850, 2900 BSP Not Shown F, NPT, 3.5 gpm Brass F, NPT, 4.0 gpm Brass F, NPT, 4.5 gpm Brass F, NPT, 5.0 gpm Brass F, NPT, 60 gpm Brass NPT, 70 gpm Brass NPT, 8.0 gpm Brass NPT, 9.0 gpm Brass NPT, 10 gpm Brass NPT, 12 gpm Brass NPT, 15 gpm Brass NPT, 20 gpm Brass NPT, 25 gpm Brass Control, 30 gpm 1-1/2 inch 2850/2900/9500 * Do not use O-ring if control is side mounted. Item No. QTY Part No. Description CONTROL VALVE WITH 1700 INJECTOR ASSEMBLY CONTINUED

FLECK 2850 Control Valve Service Manual • 23

1600 SERIES BRINE SYSTEM

Item No. QTY Part No. Description 1/4 PT x 3/8Tube 2850/2900s w/Quad Ring with seat

60029 Rev C

Item No. QTY Part No. Description

24 • FLECK 2850 Control Valve Service Manual

60036 Rev C

Item No. QTY Part No. Description Brass Brass Brass *Upflow Only

FLECK 2850 Control Valve Service Manual • 25

1650 BRINE SYSTEM ASSEMBLY

60011 Rev D

Item No. QTY Part No. Description 1/4 NPT x 3/8T 18-8 Stainless Steel Grey Grey Grey Grey Grey Item No. QTY Part No. Description

26 • FLECK 2850 Control Valve Service Manual Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Brown Grey Grey Grey Grey Grey Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel

1650 BRINE SYSTEM ASSEMBLY CONTINUED

Item No. QTY Part No. Description GPM GPM GPM Plastic Plastic Plastic Plastic Brass Brass Brass *Upflow Only **Item 14 includes Items 25 and 26 Item No. QTY Part No. Description

FLECK 2850 Control Valve Service Manual • 27

1700 BRINE SYSTEM ASSEMBLY

60034 Rev D

28 • FLECK 2850 Control Valve Service Manual Item No. QTY Part No. Description 1/2T x 3/8 NPT Item No. QTY Part No. Description x 2-3/4-inch 18-8 Stainless Steel Complete Complete Complete Complete Not Shown: 3/4 x 3/4 Slip *Upflow Only NOTE: Item number 26 (11893) is used on injector sizes 2 through 5C. Part number 10228 is used on injector sizes 6C.

1700 BRINE SYSTEM ASSEMBLY CONTINUED

FLECK 2850 Control Valve Service Manual • 29

60604 Rev F

Item No. QTY Part No. Description Top 2900 Bottom 8-32 X 5/16 Plastic Tube

1710 BRINE SYSTEM ASSEMBLY

1.0 gpm 1.2 gpm 1.5 gpm 2.0 gpm 2.4 gpm 3.0 gpm 4.0 gpm 5.0 gpm Not Shown Item No. QTY Part No. Description

30 • FLECK 2850 Control Valve Service Manual

1600 SERVICE VALVE OPERATOR

ASSEMBLY (OLD STYLE) Item No. QTY Part No. Description w/Seat 1/4-inch x 3/8-inch 1600, Old Style, Complete

60150 Rev A

FLECK 2850 Control Valve Service Manual • 31 1-INCH BRASS METER ASSEMBLY Item No. QTY Part No. Description #10 - 24 x .50 Plastic Connect Connect Plastic Range, Brass, Paddlewheel NPT, STD Nickel Plated, Paddlewheel NPT, STD, Brass, Hot Water, Paddlewheel Item No. QTY Part No. Description NPT EXT Range Inline, NPT, EXT Brass Body, Nickel Plated, Paddlewheel Not Shown Range, Brass, Hot Water Range, Brass, Hot Water

32 • FLECK 2850 Control Valve Service Manual 1-1/2 INCH BRASS METER ASSEMBLY Item No. QTY Part No. Description Meter Range, Plastic Plastic x 1/2 18-8 Stainless Steel 1-1/2 inch Connector STD, Brass, Paddlewheel Inline, NPT, STD Brass Body, Nickel Plated, Paddlewheel inch Inline, NPT, STD Brass, Hot Water, Paddlewheel inch, BSP, STD, Brass, Paddlewheel Inline, BSP, STD, Brass Body, Nickel Plated, Paddlewheel inch Inline, NPT, STD, Brass Body, Paddlewheel, Sleeve to 1-inch inch Inline, NPT, STD Nickel Plated, Paddlewheel, Sleeve to 1-inch inch Inline, BSP, STD, Paddlewheel, Sleeve to 1-inch inch Inline, BSP/MET STD, Nickel Plated, Paddlewheel, 1-inch Sleeve STD, Brass Paddlewheel Inline, NPT, EXT Nickel Plate, Paddlewheel NPT, EXT Brass, Hot Water, Paddlewheel EXT, Brass, Paddlewheel BSP EXT, Brass Body, Nickel Plate, Paddlewheel inch Inline, NPT, EXT Brass Body, Paddlewheel, Sleeve to 1-inch inch Inline, NPT, EXT Nickel Plated, Paddlewheel, Sleeve to 1-inch inch Inline, BSP, EXT Brass Body, Paddlewheel, Sleeve to 1-inch inch Inline, BSP, EXT, Nickel, Paddlewheel, Sleeve to 1-inch Not Shown inch x 1-inch Brass, Hot Water Brass, Hot Water Item No. QTY Part No. Description 1211 7 8

FLECK 2850 Control Valve Service Manual • 33 1-1/2 INCH STAINLESS STEEL METER ASSEMBLY Item No. QTY Part No. Description 1 inch & 1-1/2 inch Meter, Standard Range 1 inch & 1-1/2 inch Meter, Extended Range Inline, Stainless Steel, NPT, Standard Range Inline, Stainless Steel, NPT, Extended Range Inline, Stainless Steel, BSP, Standard Range Inline, Stainless Steel, BSP, Extended Range (Optional on models with electronic controls) (Optional on models with electronic controls) Not Shown (optional) 1-1/2 inch to 1 inch (optional) IMPORTANT: For valves equipped with electromechanical timers and stainless steel meters, refer to the Meter Dome and Union Orientation section.

34 • FLECK 2850 Control Valve Service Manual Item No. QTY Part No. Description Less Elbow 1/4 NPT x 3/8 Tube Hydro Long Long Long Long

60027 Rev D

2300 SAFETY BRINE VALVE

Item No. QTY Part No. Description

FLECK 2850 Control Valve Service Manual • 35

2310 SAFETY BRINE VALVE

Item No. QTY Part No. Description 2310 10-24 x .75 Black 2310 w/8.06-inch Rod w/10.5-inch Rod w/11.5-inch Rod Rod Rod Hydro Long Long Long Long Long Long Long Long Long Item No. QTY Part No. Description

36 • FLECK 2850 Control Valve Service Manual

2350 SAFETY BRINE VALVE

Item No. QTY Part No. Description Water Less Fittings Commercial, Hot Water Less Fittings Not Shown 2350

FLECK 2850 Control Valve Service Manual • 39 Problem Cause Correction Water conditioner fails to regenerate. Electrical service to unit has been interrupted Assure permanent electrical service (check fuse, plug, pull chain, or switch) Timer is defective. Replace timer. Power failure. Reset time of day. Hard water. By-pass valve is open. Close by-pass valve. No salt is in brine tank. Add salt to brine tank and maintain salt level above water level. Injector screen plugged. Clean injector screen. Insufficient water flowing into brine tank. Check brine tank fill time and clean brine line flow control if plugged. Hot water tank hardness. Repeated flushings of the hot water tank is required. Leak at distributor tube. Make sure distributor tube is not cracked. Check o-ring and tube pilot. Internal valve leak. Replace seals and spacers and/or piston. Unit used too much salt. Improper salt setting. Check salt usage and salt setting. Excessive water in brine tank. See "Excessive water in brine tank". Loss of water pressure. Iron buildup in line to water conditioner. Clean line to water conditioner. Iron buildup in water conditioner. Clean control and add mineral cleaner to mineral bed. Increase frequency of regeneration. Inlet of control plugged due to foreign material broken loose from pipes by recent work done on plumbing system. Remove piston and clean control. Loss of mineral through drain line. Air in water system. Assure that well system has proper air eliminator control. Check for dry well condition. Improperly sized drain line flow control. Check for proper drain rate. Iron in conditioned water. Fouled mineral bed. Check backwash, brine draw, and brine tank fill. Increase frequency of regeneration. Increase backwash time. Excessive water in brine tank. Plugged drain line flow control. Clean flow control. Plugged injector system. Clean injector and screen. Timer not cycling. Replace timer. Foreign material in brine valve. Replace brine valve seat and clean valve. Foreign material in brine line flow control. Clean brine line flow control. Softener fails to draw brine. Drain line flow control is plugged. Clean drain line flow control. Injector is plugged. Clean injector Injector screen plugged. Clean screen. Line pressure is too low. Increase line pressure to 20 psi Internal control leak Change seals, spacers, and piston assembly. Service adapter did not cycle. Check drive motor and switches. Control cycles continuously. Misadjusted, broken, or shorted switch. Determine if switch or timer is faulty and replace it, or replace complete power head. Drain flows continuously. Valve is not programming correctly. Check timer program and positioning of control. Replace power head assembly if not positioning properly. Foreign material in control. Remove power head assembly and inspect bore. Remove foreign material and check control in various regeneration positions. Internal control leak. Replace seals and piston assembly. TROUBLESHOOTING

40 • FLECK 2850 Control Valve Service Manual WATER CONDITIONER FLOW DIAGRAMS

1 Service Position

Hard water enters unit at valve inlet and flows down through the mineral in the mineral tank. Conditioned water enters center tube through the bottom distributor, then flows up through the center tube, around the piston, and out the outlet of the valve.

2 Backwash Position

Hard water enters unit at valve inlet, flows through piston, down center tube, through bottom distributor, and up through the mineral, around the piston and out the drain line.

3 Brine Position

Hard water enters unit at valve inlet, flows up into injector housing and down through nozzle and throat to draw brine from the brine tank, brine flows down through mineral and enters the center tube through bottom distributor and out through the drain line.

4 Slow Rinse Position

Hard water enters unit at valve inlet, flows up into injector housing and down through nozzle and throat, around the piston, down through mineral, enters center tube through bottom distributor, flows up through center tube, around piston and out through drain line.

5 Rapid Rinse

Hard water enters unit at valve inlet, flows directly from inlet down through mineral into center tube bottom distributor and up through center tube, around piston and out through the drain line.

6 Brine Tank Refill Position

Hard water enters unit at valve inlet, flows up through the injector housing, through the brine valve to refill the brine tank.

FLECK 2850 Control Valve Service Manual • 41 FLOW DATA & INJECTOR DRAW RATES

42 • FLECK 2850 Control Valve Service Manual DIMENSIONS 2.97 [7 5.5] 2.50 [6 3.5] 6.60 [1 67.5] 11.90 [3 02.3] 7.90 [2 00.5] 10.17 [2 58.3] 6.57 [1 66.8] 1.20 [3 0.5] 1.78 [4 5.1] .92 [2 3.4] 61500-2850 LNE Rev C

FLECK 2850 Control Valve Service Manual • 43 SYSTEM #4 Typical Single Tank Installation with Optional Meter SYSTEM #5 INTERLOCK Typical Twin Tank Installation with Optional Meter Interlock and No Hard Water Bypass

44 • FLECK 2850 Control Valve Service Manual SYSTEM #6 Twin Series Regeneration Installation with a Remote Meter SYSTEM #7 Twin Alternator Installation with a Remote Meter

FLECK 2850 Control Valve Service Manual • 45 SYSTEM #4 WIRING Single Valve Regeneration Immediate and Delayed Valve Wiring

19201 Rev C

46 • FLECK 2850 Control Valve Service Manual SYSTEM #4 WIRING CONTINUED With Remote Starter Valve Wiring

13768 Rev G

FLECK 2850 Control Valve Service Manual • 47 SYSTEM #5 WIRING Interlocked Regeneration Valve Wiring 40502-01 Rev C 40502-02 Rev C

48 • FLECK 2850 Control Valve Service Manual SYSTEM #6 WIRING Series Regeneration Valve Wiring 13632-01 Rev L 13632-02 Rev L

FLECK 2850 Control Valve Service Manual • 49 SYSTEM #7 WIRING Alternating Regeneration 24V / 120V / 3-Way Solenoid Output Valve Wiring 17727-01 Rev E 17727-02 Rev E

50 • FLECK 2850 Control Valve Service Manual SERVICE ASSEMBLIES

24 Hour Gear Assemblies

12 A.M. w/Silver Label w/Silver Label w/Silver Label Times/Day, w/Silver Label Adapters 2850/2900/2930 NP 2850/2900/2930 BSP/MTC 2850/2900/2930 BSP/NP 2850/2900/2930 Air Checks Less Fittings HW Less Fittings Auxiliary Micro Switch Screws Brine Line Flow Control (BLFC) Brine Valves Std O-rings (Specify flow control 1.0 - 5.0) (Specify flow control 1.0 - 5.0) Cam Assemblies Covers Drain Line Flow Controls (Specify flow control .6 - 7.0) (Specify flow control 8.0 - 25.0) (Specify flow control 8.0 - 25.0) (Specify flow control 8.0 - 25.0) (Specify flow control .6 - 7.0) Drive Assemblies Injector Assemblies (Complete) (Specify size of Injector (Specify size of injector) (Specify size of injector) Meters Meter Assembly, Standard Range Meter Assembly, Extended Range Meter Assembly, Standard Range Meter Assembly, Extended Range w/1-inch NPT Plstc Connector w/1-inch NPT Brass Connector w/ 1-1/2 inches NPT Brass Connector Piston Assemblies NHWBP NHWBP NHWBP Program Wheel Assemblies 1-1/2 inches Std Set @ 100 Set @ 50

FLECK 2850 Control Valve Service Manual • 51 Safety Brine Valves

2300 Fitting Facing Arm

Seal & Spacer Kits Service Equipment Service Valve Operator Assemblies (SVO) Skipper Wheel Assemblies SERVICE ASSEMBLIES CONTINUED

For Fleck Product Warranties visit: Fleck para las garantías de los productos visite: Pour Fleck garanties produit visitez le site : waterpurification.pentair.com WATER QUALITY SYSTEMS

5730 NORTH GLEN PARK ROAD, MILWAUKEE, WI 53209

§For a detailed list of where Pentair trademarks are registered, please visit waterpurification.pentair.com/brands. Pentair trademarks and logos are owned by Pentair plc or its affiliates. Third party registered and unregistered trademarks and logos are the property of their respective owners. 16510 REV M MY16 © 2016 Pentair Residential Filtration, LLC All Rights Reserved.