25 – 95 mm2 AWG 4 – 4/0 WAGO Kontakttechnik GmbH & Co. KG P.O. Box 28 80 · 32385 Minden Hansastraße 27 · 32423 Minden Fax ++49/5 71/8 87 - 169 info@wago.com www.wago.com 51 191413· 0888-0174/0001-3601 · POWER CLAMP · 08/07 · JA 70821 · Printed in Germany · Technical changes reserved The Range of Rail Mounted Terminal Blocks for Wire Sizes Ranging from 6 mm2/ AWG 8 to 95 mm2/AWG 4/0 4 045454 558031 Voltage Tap2-Conductor Ground (Earth) Terminal Blocks2-Conductor Through Terminal Blocks Item no. Rated cross section Rated voltage Rated current Stripped length Adjacent jumper Hex wrench Protective warning marker Finger guard cover Test plug Item no. Rated cross section Rated voltage Rated current Stripped length Adjacent jumper Hex wrench Protective warning marker Finger guard cover Test plug Item no. Rated cross section Rated voltage Rated current Stripped length 25–95 mm2
1000 V / 8 kV / 3
AWG 4–4 / 0 600 V 1.38 in 0.2 – 10/16 mm2 A 16 – 17 mm AWG 24–6 0.65 in grey 285-495 285-172 yellow 285-170 yellow 285-169 25–95 mm2 35 mm AWG 4–4 / 0 1.38 in grey 285-495 285-172 yellow 285-170 yellow 285-169 AWG 8–2 / 0 600 V 1.18 in 2 x 0.2 – 6 mm2 A 12 – 13 mm AWG 24–10 0.49 in grey 285-450 285-172 yellow 285-440 yellow 285-441 30 mm AWG 8–2 / 0 1.18 in grey 285-450 285-172 yellow 285-440 yellow 285-441 green-yellow 285-137 6–35 mm2 AWG 8–2 600 V 0.98 in 0.2 – 6 mm2
800 V / 8 kV / 3
12 – 13 mm AWG 24–10 0.49 in grey 285-135 blue 285-134 grey 285-435 210-621 yellow 285-420 yellow 285-421 283-404 6–35 mm2 25 mm AWG 8–2 0.98 in grey 285-435 210-621 yellow 285-420 yellow 285-421 283-404 grey 285-427 green-yellow 285-157 grey 285-150 blue 285-154 grey 285-447 green-yellow 285-197 grey 285-195 blue 285-194 grey 285-407 35 mm2 50 mm2 95 mm295 mm2 The Full Range of High Current Terminal Blocks Strain relief plate 769-410 Test plug Ø 2 mm / 0.079 in 210-136 Test plug Ø 2.3 mm / 0.091 in 210-137 not offered by WAGO not offered by WAGO not offered by WAGO not offered by WAGO not offered by WAGO not offered by WAGO Voltage Tap2-Conductor Ground (Earth) Terminal Blocks2-Conductor Through Terminal Blocks Voltage Tap2-Conductor Ground (Earth) Terminal Blocks2-Conductor Through Terminal Blocks 2.48 in 2.48 in
In addition to the WSB marking system, custom marking strips can also be used. Commoning adjacent terminal blocks using centrally positioned adjacent jumpers. . . . A small counter-clockwise rotation releases the latch ➊. Once the screw- driver ➋ has been removed the conduc- tor is clamped safely. Marking Voltage tap Attention! Health hazard! Keep your fingers out of the conductor entry hole! Commoning with adjacent jumper. Insertion of jumper above the conductor entry hole, without tools. Rated cross section is still 50 mm2/AWG 2/0 and 95 mm2/AWG 4/0. Commoning Covers provide touchproof safety by closing unused clamping units and jumper contact slots (detach the cover of the jumper contact slot from the touch protection cover of the clamping unit) Touch protection cover
1000 V AWG 8 – 2
1000 V AWG 8–2/0
1000 V AWG 4 – 4/0
Introduce stripped wire into the clamping unit up to the stop and hold it in position . . . Counter-clockwise rotation using a screwdriver (blade width 5.5 mm). Hold clamp in open position using the latch. Wire connection 35 mm2 Connecting Conductors up to 95 mm2 /AWG 4/0 with a Turn of the Hand The Range of Rail Mounted Terminal Blocks for Wire Sizes Ranging from 6 mm2 / AWG 8 to 95 mm2 / AWG 4/0 Testing using test plug adapters (accessory) for Ø 4 mm plugs. Move the marking strip laterally to remove the jumper. Voltage tap The voltage tap is inserted into the jumper contact slot. It can be fitted with a strain relief plate and provides test option for Ø 2 mm/2.3 mm test plugs. Testing with test plug Ø 4 mm Protective warning marker may indicate: Attention! Voltage may be present despite main circuit being switched off! Protective warning marker Safety notice . . . A small counter-clockwise rotation releases the latch ➊. Once the hex wrench ➋ has been removed the con- ductor is clamped safely. Introduce stripped wire into the clamping unit up to the stop and hold it in position . . . Counter-clockwise rotation using a hex wrench. Hold clamp in open position using the latch. Wire connection 50 / 95 mm2 Reliable and simple tap directly onto the power supply. Insert the unwired tap before ope- ning the pressure spring.