Product: 2824RW Indoor/Outdoor Stadium Cable, 3-Channel SMPTE, 6 Fiber, 6 Conductor 18 AWG, 6 Conductor 24 AWG, CPE Jacket Product Description Indoor/Outdoor, 3-Channel SMPTE Stadium Cable, 6 Single Mode Fibers, 6 TC Conductor 18 AWG (19x30) and 6 TC Conductor 24 AWG (7x32), Beldfoil Shields, Water Blocking Tape, CPE Jacket Technical Drawing Technical Specifications Product Overview Suitable Applications: 3 Channel Composite Camera Cable Multiconductor Multiconductor Conductor and Insulation Element No. of Conductors AWG Stranding Material Nominal Conductor DCR Insulation Material Insulation Nominal Diameter Quad 1, Quad 2, Quad 3 6 24 7x32 TC - Tinned Copper 23.3 Ohm/1000ft PVC - Polyvinyl Chloride 0.038 in Quad 1, Quad 2, Quad 3 6 18 19x30 TC - Tinned Copper 6.67 Ohm/1000ft PVC - Polyvinyl Chloride 0.080 in Multiconductor Color Chart Description Color Quad 1 - 24AWG Red Quad 1 - 24AWG Gray Quad 1 - 18AWG White Quad 1 - 18AWG Black Quad 2 - 24AWG Red/Yellow Quad 2 - 24AWG Gray/Yellow Quad 2 - 18AWG White/Yellow Quad 2 - 18AWG Black/Yellow Quad 3 - 24AWG Red/Orange Quad 3 - 24AWG Gray/Orange Quad 3 - 18AWG White/Orange Quad 3 - 18AWG Black/Orange Multiconductor Inner Shield Layer Inner Shield Type Inner Shield Material Inner Shield Coverage Drainwire AWG Drainwire Stranding Drainwire Material Drainwire Position

Quad Tape Al/poly (Foil in) 100 % 22 7x30 TC - Tinned Copper Under Each Quad's Shield Tape Multiconductor UL Voltage UL Description UL Voltage Rating

24 AWG 300 V RMS

18 AWG 300 V RMS

OS2, G.657.A2 6 Fiber Color Coding: Yellow Printed Subunit Diameter: 0.078 in (2.0 mm) Buffer Specification Buffer Material Buffer Diameter PVC - Polyvinyl Chloride 900 µm Number of Active Subunits: 6 Number of Subunit Positions: 6 Fibers Per Subunit: 1 Subunit Waterblocking: Aramid Yarn Mode Field Diameter: 9.2 µm Wavelength@Optical SM1: 1310 nm, 1550 nm Max. Attenuation at 1310 nm: 0.50 dB/km Max. Attenuation at 1550 nm: 0.50 dB/km Overall Cable Jacket: CPE Operating Temperature Range: -40°C to 70°C Installation Temperature Range: -10°C to 70°C Storage Temperature Range: -40°C to 70°C Max. Pull Tension: 2700 N Bulk Cable Weight: 134 lbs/1000ft Applicable Standards & Environmental Programs NEC/(UL) Compliance: CMR EU Directive 2011/65/EU (RoHS 2): Yes EU Directive 2015/863/EU (RoHS 2 amendment): Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire and Cable): Yes China RoHS II (GB/T 26572-2011): Yes Suitability Suitability - Indoor: Yes Suitability - Outdoor: Yes Flame Test UL Flammability: UL1666 Vertical Shaft Plenum/Non-Plenum Plenum (Y/N): No Product Notes Notes: Copper conductor quads are individually shielded with individual drain wire History

Update and Revision: Revision Number: 0.144 Revision Date: 11-09-2022 Variants Item # Color UPC Length 2824RW 005CUT Green 2824RW 0051000 Green, Dark 612825400066 1,000 ft 2824RW 0055000 Green, Dark 612825400073 5,000 ft © 2023 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.