ibaeaahecr] Weidmiiller 3 FSRO315024 FG Weidmiiller Interface GmbH & Co. KG KlingenbergstraBe 26 D-32758 Detmold Germany www.weidmueller.com Product image The SAFESERIES Contact Extension uses relays with General ordering data forcibily giuded contacts in accordance with EN 618 00-3 Type A. This makes it predestined for signal monitoring in Version SAFESERIES, Relay with positively driven contacts applications for the protection of people and machinery. It 1. NC and 3 NO contacts forcibily guided (EN ensures safe feedback to the control level. Consisting of 4 918103 pe 8 AgSnO goles Rete on different pluggable relays with matching screw sockets in Test button available: No the contact version 2NO+2NC,3NO+1NC,4NO+2 Order No. 2759030000 NC, and 3 NO + 3 NC. When the application is designed ee according to EN/ISO 13849-1, a performance level of PL ay Spots, =SSOSSC*CSCS "e" can be achieved. The basic component is also suittatle ee for safety applications according to IEC/EN 62061 in order to achieve a safety integrity level of SIL3. * Relay with forcibily giuded contacts to EN 61810-3 typeA * cULus listed approval for high acceptance on the North American market * COC approval for conformity with Chinese quality standards * Assembled and 100 % functionally tested KIT consisting of relay and socket with integrated status LED * Diagnosis coverage of 99 %

| Data sheet | sheet FSR0O315024 FG Weidmiiller Interface GmbH & Co. KG Klingenbergstrabe 26 D-32758 Detmold Germany www.weidmueller.com | Technical data | data Dimensions and weights Depth 24mm Depth (inches) 0.945 inch Height 40 mm Height (inches) 1.575 inch Width 13 mm Width (inches) 0.512 inch Net weight 209 Temperatures Humidity 5...85 %, no condensation Control side Rated control voltage 24V DC +10 % Rated current DC 15 mA Power rating 360 mW Pullin/drop-out voltage, typ. 18V/24V DC Coil resistance 1600Q + Status indicator No Load side Rated switching voltage 250 VAC Continuous current 6A Max. switching frequency at rated load_0.1 Hz Max. switching voltage, AC 400 V Max. switching voltage, DC 250V Inrush current 30A/20ms AC switching capacity (resistive), max. 1500 VA DC switching capacity (resistive), max. 144 W @ 24 V Switch-on delay <20ms Switch-off delay <20ms Contact type 1 NC and 3 NO contacts Mechanical service life forcibily guided (EN 618 10-3 type A) (AgSnO- —goletptated) 10 10? switching cycles _ Min. switching power 2mA@ 24V,4 mA@ 12 Vv, 10 mA @5V General data Operating altitude < 2000 m Test button available No Colour Transparent UL94 flammability rating component | Component Relay cover UL94 flammability rating V2 Component Relay baseplate UL94 flammability rating V-0 Insulation coordination Insulation coordination according to IEC 61810-1 Rated voltage 250V Pollution severity 2 Surge voltage category tl Clearance and creepage distances for Dielectric strength for control side - load . controlside-oadside 0 Bmm sid fin Type of isolation at input and output Dielectric strength of neighbouring ; reinforced insulation contacts 2.5 kVet/ 1 min Type of isolation at neighbouring Dielectric strength of open contact ; contacts Basic insulation 1.5 kVer /1_ min. Impulse withstand voltage at input and Impulse withstand voltage at ‘output 10 kV (1.2/50 us) neighbouring contacts 5 kV (1.2/50 us) Protection degree IP50

| Data sheet | sheet FSR0O315024 FG Weidmiiller Interface GmbH & Co. KG Klingenbergstrage 26 D-32758 Detmold Germany www.weidmueller.com | Technical data | data Further details of approvals / standards Standards EN 61810-3 Classifications ETIM 6.0 E£C001437 ETIM 7.0 £C001437 ETIM 8.0 EC001437 ECLASS 9.0 27-37-16-01 ECLASS 9.1 27-37-1601 ECLASS 10.0 27-37-16-01 ECLASS 11.0 27-37-16-01 ECLASS 12.0 27-37-16-01 Downloads Engineering Data CAD data - STEP Catalogues Catalogues in PDF-format

| Data sheet | sheet FSRO315024 FG Weidmiiller Interface GmbH & Co. KG KlingenbergstraBe 26 D-32758 Detmold Germany | Drawings | www.weidmueller.com Wiring diagram Graph DC load breaking capacity == son eee 8 oo oN TIT THT att = SEMI : OAI ' = x— eee ‘ 11.12 33 34 = a SS ' ' a a : 23 24 43 44: a : OA2 ‘ a ot ert : yy eC ET e_| UT ETH 0102 05 1 2 5 10 Switching current [A] View of Pins from below Graph Dimensional drawing Electrical endurance

250 VAC resistive load

6 SSS SSS

a — | 40 mm 13mm, Ca | a a ow _ ee —— g a a 3 ot | | tT 7] o 1 2 3 4 5 6 Switching Curent (A)

| Data sheet | sheet FSRO315024 FG Weidmiiller Interface GmbH & Co. KG KlingenbergstraBe 26 D-32758 Detmold Germany | Drawings | www.weidmueller.com Type codes CoOODOOOC AC 4) FS Functional Safety il Type of contact addition FG Forcibly Guided R Relay contacts Coil voltage Numbers of 005 «5 VOC changeover contacts 012 =«12VDC 024 =«624V0C 048) «=48V0C Numbers of normally open contacts Coutact ssateital

0 AgNi

Niimbors of i aN tes Li plated normally close contacts nS aoe eet

3 AgSn0

4 AgSn0 flash gold plated

5 AgSn0 gold plated