Creation date September 14, 2021 4:23:39 AM CEST Catalogue status 10.09.2021 / We reserve the right to make technical changes. 1 TGD ELM-4 CL2 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Modern machines and plants require load monitoring systems capable of communication. topGUARD - the IO-Link-capable load monitoring system - offers remote control options, full data transparency and reliable protection of the 24-volt system voltage. topGUARD is the ideal complement to IO-Link capable PROtop power supplies from innovative power management systems. It follows the innovative approach to integrated potential distribution, which saves space and time in device installation. A communication module simply needs to be connected and an IODD file integrated in order to carry out parameterisation and control, and to provide all operating data. General ordering data Version Electronic load monitoring Order No. 2656670000 Type TGD ELM-4 CL2 GTIN (EAN) 4050118686241 Qty. 1 pc(s).

TGD ELM-4 CL2 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Technical data Creation date September 14, 2021 4:23:39 AM CEST Catalogue status 10.09.2021 / We reserve the right to make technical changes. 2 Dimensions and weights Depth 96.5 mm Depth (inches) 3.799 inch Height 125 mm Height (inches) 4.921 inch Width 12.2 mm Width (inches) 0.48 inch Net weight 90 g Temperatures Probability of failure SIL in compliance with IEC 61508 None Environmental Product Compliance REACH SVHC Lead 7439-92-1 Input DC input voltage range 18…30 V DC Input fuse (internal) Yes Rated input voltage

24 V DC

max. admissible residual ripple at the input 100 mVpp Output Capacitive load 4.700 µF Connection system PUSH IN Rated current 4 A Rated current (per channel) 4 A Triggering characteristic see characteristic curve adjustable rated current Yes General data Conformal coating No Function key Activation time < 3s, Reset, ON MTTF According to Standard SN 29500 Operating time (hours), min. 2.154 Mh Ambient temperature 40 °C Input voltage 24 V Output power 96 W Duty cycle 100 % Operating temperature -25 °C...70 °C Relay to activate the output No Surge voltage category III Insulation coordination Surge voltage category III Connection data (output) Conductor cross-section, AWG/kcmil , max. 12 Conductor cross-section, AWG/kcmil , min. 26 Conductor cross-section, flexible , max. 2.5 mm² Conductor cross-section, flexible , min. 0.14 mm² Conductor cross-section, rigid , max. 2.5 mm² Conductor cross-section, rigid , min. 0.14 mm² Connection system PUSH IN Number of terminals 2 (+ / -)

TGD ELM-4 CL2 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Technical data Creation date September 14, 2021 4:23:39 AM CEST Catalogue status 10.09.2021 / We reserve the right to make technical changes. 3 Signalling LED green Operation (failure-free), Early warning: I Out > 90% I Rated (flashing) Red LED Load monitoring has disconnected, Load monitoring has triggered (flashing), Internal error (rapid flashing) Yellow LED Address is assigned, Address is being assigned (flashing) Approvals Certificate no. (cULus) E258476 Institute (cULus) CULUS Classifications ETIM 6.0 EC002057 ETIM 7.0 EC002057 ETIM 8.0 EC002057 ECLASS 9.0 27-37-10-16 ECLASS 9.1 27-37-10-16 ECLASS 10.0 27-37-10-16 ECLASS 11.0 27-37-10-16 Approvals Approvals ROHS Conform UL File Number Search E258476 Downloads Approval/Certificate/Document of Conformity decleration of conformity Engineering Data STEP User Documentation Operating instructions / leaflet Catalogues Catalogues in PDF-format

TGD ELM-4 CL2 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Drawings Creation date September 14, 2021 4:23:39 AM CEST Catalogue status 10.09.2021 / We reserve the right to make technical changes. 4