2625000000 WEIDMULLER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
Creation date September 14, 2021 4:23:44 AM CEST Catalogue status 10.09.2021 / We reserve the right to make technical changes. 1 TGD FIM-C Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Modern machines and plants require load monitoring systems capable of communication. topGUARD - the IO-Link-capable load monitoring system - offers remote control options, full data transparency and reliable protection of the 24-volt system voltage. topGUARD is the ideal complement to IO-Link capable PROtop power supplies from innovative power management systems. It follows the innovative approach to integrated potential distribution, which saves space and time in device installation. A communication module simply needs to be connected and an IODD file integrated in order to carry out parameterisation and control, and to provide all operating data. General ordering data Version Supply module Order No. 2625000000 Type TGD FIM-C GTIN (EAN) 4050118689419 Qty. 1 pc(s).
TGD FIM-C Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Technical data Creation date September 14, 2021 4:23:44 AM CEST Catalogue status 10.09.2021 / We reserve the right to make technical changes. 2 Dimensions and weights Depth 85.5 mm Depth (inches) 3.366 inch Height 125 mm Height (inches) 4.921 inch Width 35 mm Width (inches) 1.378 inch Net weight 128 g Temperatures Probability of failure SIL in compliance with IEC 61508 None Environmental Product Compliance REACH SVHC Lead 7439-92-1 Input Connection system PUSH IN DC input voltage range 18…30 V DC Input fuse (internal) No Rated input voltage 24 V DC Surge protection Suppressor diode max. admissible residual ripple at the input 100 mVpp Output Rated current (per channel) 40 A Surge protection Suppressor diode General data Conformal coating No MTTF According to Standard SN 29500 Operating time (hours), min. 2.479 Mh Ambient temperature 40 °C Input voltage 24 V Duty cycle 100 % Operating temperature -25 °C...70 °C Surge voltage category III Insulation coordination Surge voltage category III Connection data (input) Conductor cross-section, AWG/kcmil , max. 6 Conductor cross-section, AWG/kcmil , min. 18 Conductor cross-section, flexible , min. 0.75 mm² Conductor cross-section, rigid , max. 10 mm² Conductor cross-section, rigid , min. 0.75 mm² Connection system PUSH IN Wire connection cross section, flexible (input), max. 16 mm²
TGD FIM-C Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Technical data Creation date September 14, 2021 4:23:44 AM CEST Catalogue status 10.09.2021 / We reserve the right to make technical changes. 3 Signalling LED green/red Station ok (slow flashing green, 1.5 Hz), Device ok (fast flashing green, 13 Hz), Station error (slow flashing red, 1.5 Hz), Device error (fast flashing red, 13 Hz) Yellow LED Address is assigned, Addresses being assigned (slow flashing, 1.5 Hz), Address error (fast flashing, 13 Hz) Approvals Certificate no. (cULus) E258476 Institute (cULus) CULUS Classifications ETIM 6.0 EC002057 ETIM 7.0 EC002057 ETIM 8.0 EC002057 ECLASS 9.0 27-37-10-16 ECLASS 9.1 27-37-10-16 ECLASS 10.0 27-37-10-16 ECLASS 11.0 27-37-10-16 Approvals Approvals UL File Number Search E258476 Downloads Approval/Certificate/Document of Conformity decleration of conformity Engineering Data STEP User Documentation Operating instructions / leaflet Catalogues Catalogues in PDF-format
TGD FIM-C Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Drawings Creation date September 14, 2021 4:23:44 AM CEST Catalogue status 10.09.2021 / We reserve the right to make technical changes. 4 Schematic circuit diagram