25SQ035-25A-R-6 DGNJDZ | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
FEATURES
- Guard ring for transient protection
- Low power loss,high efficiency
- High current capability,low VF
- High surge capacity MECHANICAL DATA
- Case: R-6 molded plastic
- Polarity: As marked on the body
- Mounting position :Any MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Rating at 25℃ ambient temperature unless otherwise specified. Single phase, half wave ,60Hz, resistive or inductive load. For capacitive load, derate current by 20% 25SQ 25SQ 25SQ 25SQ 25SQ 25SQ 25SQ 030 035 040 045 050 055 060 Maximum Recurrent Peak Reverse Voltage V RRM 30 35 40 45 50 55 60 V Maximum RMS Voltage V RMS 21 25 28 32 35 39 42 V Maximum DC Blocking Voltage V DC 30 35 40 45 50 55 60 V Maximum Average Forward Rectified Current ( See Fig.1) @TC=95 ℃ Peak Forward Surge Current 8.3ms Single Half Sine-Wave Super Imposed on Rated Load (JEDEC Method) Peak Forward Voltage at 12.5A DC(Note1) V F V Maximum DC Reverse Current @TJ=25℃ at Rated DC Bolcking Voltage @TJ=125℃ Typical Thermal Resistance(Note2) RθJc ℃/W Operating Temperature Range T J ℃ Storage Temperature Range TSTG ℃ 0.55 0 .7 -55 to +200 2.ThermalResistanceJunctiontolead/terminalatadistance1mmfromcase. 0.5 -55 to +200 I(AV) A25
275 AIFSM
NOTES:1.300us pulse width,2% dudy cycle. 1.8 wheeling,and polarity protection applications classification 94V-0
- For use in low voltage,high frequency inverters,free
- Plastic package has UL flammability REVERSE VOLTAGE - 30 to 60Volts FORWARD CURRENT - 25.0 Amperes CHARACTERISTICS UNITSYMBOL
- Metal of silicon rectifier , majority carrier conduction HER608 25SQ030 25SQ060THRU SCHOTTKY BARRIER RECTIFIERS R-6 Dimensions in inches and (millimeters) 0.945(24.0) MIN. 0.945(24.0) MIN. .360(9.1) .360(9.1) .340(8.6) .340(8.6) .052(1.3) .043(1.1) DIA. DIA. www.dgnjdz.com
FIG. 2 – MAXIMUM NON-REPETITIVE SURGE CURRENT NUMBER OF CYCLES AT 60Hz PEAK FORWARD SURGE CURRENT, AMPERES PULSE WIDTH 8.3 ms SINGLE HALF-SINE-WAVE (JEDEC METHOD) 150 300 102 5 20 50 100 250 200 100 INSTANTANEOUS REVERSE CURRENT,(mA) PERCENT OF RATED PEAK REVERSE VOLTAGE,(%) FIG.3-TYPICAL REVER CHARACTERISTICS 40 60 80 100 120 140 20 0.1 1.0 1000 0.01 100 TJ=75℃ TJ=100℃ TJ=25℃ SINGLE PHASE HALF WAVE 60Hz RESISTIVE OR INDUCTIVE LOAD INSTANTANEOUS FORWARD CURRENT, (A) FIG.4-TYPICAL FORWARD CHARACTERISTICS INSTANTANEOUS FORWARD VOLTAGE, VOLTS 1.0 0.1 100 25SQ050-25SQ060 25SQ030-25SQ045 PULSE WIDTH 300us 2% DUTY CYCLE TJ = 25°C FIG. 1 – FORWARD CURRENT DERATING CURVE CASE TEMPERATURE (℃) AVERAGE FORWARD CURRENT AMPERES 50 75 100 125 150 175 200 www.dgnjdz.com