2560 BK | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 7
Technical content
Digital Storage and Mixed Signal Oscilloscopes
2560 Series
Technical data subject to change © B&K Precision Corp. 2019 www.bkprecision.com DSO Model 2563 2565 2566 2567 2568 2569 MSO Model 2563-MSO 2565-MSO 2566-MSO 2567-MSO 2568-MSO 2569-MSO Bandwidth 70 MHz 100 MHz 200 MHz 200 MHz 300 MHz 300 MHz Channels 4 4 2 4 2 4 Features & Benefits n Bandwidth up to 300 MHz n 2 GSa/s maximum sample rate n 140 Mpts maximum record length n 16 digital channels with logic analyzer (MSO upgrade) n Serial bus decoding supporting I2C, SPI, UART/RS232, CAN, and LIN protocols (Decode upgrade) n 25 MHz Function and Arbitrary Waveform Generator (AWG upgrade) n Large 8” widescreen display with 256-level color gradient n 140,000 wfms/s waveform capture rate n Compact footprint and lightweight n High speed hardware-based pass/fail testing function and masking n Segmented acquisition history waveform record function (record length up to 80,000 frames) n Trigger types: Edge, Slope, Pulse, Video, Window, Runt, Interval, Dropout, Pattern, Serial n FFT including seven other math functions: Addition, Subtraction, Multiplication, Division, Integration, Differential, and Square Root n 36 automatic measurements supporting statistics, gating, math, history and reference measurements n Multi-language user interface and built-in context sensitive help n Software provided for remote PC control n Front panel USB port for saving and recalling waveforms, setups, and screenshots n Standard LAN and USBTMC-compliant USB device port n Selectable 50 Ω and 1 MΩ input coupling The 2560 Digital Storage and Mixed Signal Oscilloscope (MSO) Series delivers advanced features and debug capabilities for a wide range of applications. With up to 300 MHz bandwidth in a 4-channel configuration, each model offers a maximum sample rate of 2 GSa/s, and a maximum memory depth of 140 Mpts. In addition, these oscilloscopes provide an 8” color display with 256 levels of color grading combined with a high waveform update rate up to 140,000 wfms/ sec, which allows the instruments to capture infrequent glitches with excellent signal fidelity. The logic analyzer and decode software provides 16 additional digital channels and serial bus decoding for I2C, SPI, UART/RS232, CAN, and LIN protocols. Maximize productivity using extensive features such as digital filtering, waveform recording, pass/fail limit testing, and automatic measurements. The optional 25 MHz function/ arbitrary waveform generator (AWG) provides stimulus output of 4 arbitrary waveforms, sine, square, ramp, pulse, DC, noise, cardiac, Gaussian pulse, and exponential rise/fall waveforms to the device under test. The 2560 Series oscilloscopes are ideal for applications in design, education, service, and repair. This instrument offers a comprehensive set of tools to capture signal anomalies, decode serial bus protocols, and help speed up debug and analysis. The MSO, AWG, and decoding functionalities are available for upgrade in the field with the purchase of a license key. USB (USBTMC) LAN
Digital Storage and Mixed Signal Oscilloscopes www.bkprecision.com Front panel USB host port Connect your USB flash drive to conveniently store and recall waveform data, setups, and screenshots. Auto setup Vertical, horizontal, and trigger controls are automatically adjusted for fast signal display. Advanced triggering Isolate the signal with advanced triggering including Edge, Slope, Pulse, Video, Window, Interval, DropOut, Runt, and Pattern trigger types. 8-inch TFT-LCD display 8-inch high resolution TFT-LCD display lets you see more details in your signal. Serial Decoding Decode and analyze I2C, SPI, UART/RS232, CAN, and LIN protocols and display results in binary, decimal, hex, or ASCII in real-time. Enabled with decode upgrade or try 30 times for free with each unit. Intuitive channel operation All channels in the 2560 Series are clearly indicated by their own color, labeled on the input, knobs, and display. Rear panel Kensington security slot Helps to secure your oscilloscope and prevent theft. External trigger Pass/Fail or Trig Out Output LAN and USB ports enable remote control from a PC. 16-Channel Digital Ports Connect a logic analyzer probe to access 16 digital channels enabled with MSO upgrade or try 30 times for free with each unit. Arbitrary Waveform Generator Output The 25 MHz waveform generator is enabled with the generator upgrade or try 30 times for free with each unit. AC line input and input fuse holder
Digital Storage and Mixed Signal Oscilloscopes www.bkprecision.com Fast 140,000 wfms/s Waveform Capture Rate The 140,000 wfms/s update rate in normal mode helps detect infrequent anomalies and glitches. Record Length up to 140 Mpts The hardware-based Zoom function used with the record lengths of 140 Mpts enables users to capture more of their signal and quickly zoom into the event of interest. Waveform History and Recording Quickly scroll through millions of points with History Mode’s playback functionality to find difficult to capture events. Eliminate unnecessary idle signals and dead-time by selectively capturing up to 80,000 segments. Hardware Pass/Fail and Masking The 2560 Series’ high speed hardware based pass/fail limit function can perform up to 140,000 pass/fail tests per second. PC Connectivity PC software is provided (free download at www.bkprecision.com) for seamless integration between the oscilloscope and PC. Capture and transfer waveforms, screen images, setups and measurement results to a Windows PC via the USB device port on the back of the instrument. A USB host port on the front allows for quick and easy screen saving. Enhanced Resolution Mode Enhanced Resolution (Eres) mode minimizes signal noise to reveal hidden detail when the signal is difficult to trigger and averaging methods are confined. The tools you need 256-level intensity grading and color temperature display 256-level intensity grading Color temperature display Discover and visualize more details of your signal for better analysis of its behavior.
Digital Storage and Mixed Signal Oscilloscopes www.bkprecision.com Available Upgrades
2560 Series DSO Model 2560 Series MSO Model
16-channel digital logic probe (LP2560) Optional Standard Logic analyzer license (LA2560) Optional Standard Bus decode and analysis license (DC2560) Optional Optional
25 MHz waveform generator license (FG2560) Optional Optional
16 channel logic probe - LP2560 The 16-channel color-coded logic probe consists of two eight-channel pods. To make contact with the DUT, the probe connects directly to square pins or clips to test points using the included grabbers. With an input capacitance of only 18 pF and 100 kΩ input impedance, the probe protects the integrity of your signal. The probe is included with MSO models. Buy now, upgrade later Install the MSO and decode licenses at any time or try before you buy with the 30 trial license on each model. Any DSO model in the 2560 Series can be upgraded to an MSO. Installation is quick and easily done within the oscilloscope menu. To purchase a license key, please fill out the license request form or visit the 2560 Series accessories page. MSO license - LA2560 The 16 integrated digital channels are displayed along-side analog channels allowing users to view up to 20 time-correlated channels with shared triggering and acquisition on one screen. The LA2560 license enables the 16 digital channels of the 2560 Series and is included with MSO models. Decode license - DC2560 Select up to 2 serial bus protocols I2C, SPI, UART/RS232, CAN, and LIN and decode concurrently from analog and MSO channels. Decode information in real-time and display in binary, decimal, hex, or ASCII. Included in all MSO models The tools you need AWG license - FG2560 Take advantage of the generator’s 10 built-in waveforms or generate up to 4 of your own arbitrary waveforms via waveform editing software.
Digital Storage and Mixed Signal Oscilloscopes www.bkprecision.com Specifications Series 2560 Performance Characteristics Bandwidth
300 MHz (2568/ 2569)
200 MHz (2566/ 2567)
100 MHz (2565)
70 MHz (2563)
Typical Rise Time < 1.2 ns (2568/ 2569), < 1.8 ns (2566/ 2567), Sample Rate 2 GSa/s (half-channel interleaved)(1),
1 GSa/s (per channel)
4 Analog Channels: 2563, 2565, 2567, 2569
2 Analog Channels: 2566, 2568
Digital: 16 (-MSO models or with LA2560 upgrade) Memory Depth 140 Mpts (single channel),
70 Mpts (dual channel)
Waveform Update Rate 140,000 wfms/s Hardware Bandwidth Limits 20 MHz Input Coupling DC, AC, GND Input Impedance 1 MΩ ± 2% || (22 pF ±3 pF) 50 Ω ± 2% Ch to Ch Isolation DC - Max BW > 35 dB Acquisition System Peak Detect 1 ns Average 4, 16, 32, 64, 128, 256, 512, 1024 Enhanced Resolution (Eres) 0.5, 1, 1.5, 2, 2.5, 3 bits selectable Interpolation Sin(x)/x, Linear Vertical System Vertical Resolution 8 bits Vertical Sensitivity 500 μV/div to 10 V/div (1-2-5 ) Maximum Input Voltage 1 MΩ: < 400 Vpk; 50 Ω: < 5 Vrms DC Gain Accuracy ±3%: 5 mV/div to 10 V/div; ±4%: < 2 mV/div Horizontal System Time Base Range 2.0 ns/div to 50 s/div Time Base Accuracy ±25 ppm Ch to Ch Deskew Range <100 ps Trigger System Modes Auto, Normal, Single Coupling DC, AC, LF Reject, HF Reject, Noise Reject Ch1-Ch4 Trigger Level Internal: ±4.5 div from center External: EXT: ±0.6 V EXT/5: ±3 V Hold-Off Range 100 ns to 1.5 s Types Edge, Slope, Pulse, Video, Window, Interval, Dropout, Runt, Pattern Serial Trigger I2C, SPI, UART/RS232, CAN, LIN I/O Interface Standard USB Host, USB Device, LAN, Pass/Fail, Trigger Out Pass/Fail 3.3 V TTL Output Display System Display 8” Color TFT-LCD, 800 x 480 Resolution Wave Display Mode Vectors, Dots Persistence Off, Infinite, 1 sec, 5 sec, 10 sec, 30 sec Intensity Grading 256 Levels Language English, French, Japanese, Korean, German, Russian, Italian, Portuguese, Simplified Chinese, Traditional Chinese Environmental and Safety Temperature Operating: 10 °C to +40 °C Storage: -20 °C to +60 °C Humidity Operating: 85% RH, 40 °C, 24 hours Storage: 85% RH, 65 °C, 24 hours Altitude Operating: 3,000 m Storage: 15,266 m General Power Requirements 100 to 240 VAC, CAT II, 50 VA Max,
45 Hz to 440 Hz
Dimensions (W x H x D) 13.8” x 5” x 8.8” (352 x 128 x 224 mm) Weight (4-ch) 7.9 lbs (3.6 kg) (2-ch) 7.5 lbs (3.4 kg) Three-Year Warranty Included Accessories Passive probes (one per channel), power cord, certificate of calibration, USB (Type A to B) communication cable Optional Accessories 16-channel digital logic probe (LP2560) Cursors Mode Manual, Track Measurements ∆T, 1/∆T, X2, X1, ∆V, Y2, Y1 Waveform Math Math Operation Add, Subtract, Multiply, Divide, FFT, Derivative, Integral, Square Root FFT Windows: Rectangle, Blackman, Hanning, Hamming, Flattop Waveform Measurements Voltage Vpp, Vmax, Vmin, Vamp, Vtop, Vbase, Mean, Cmean, Stdev, Cstd, Vrms, Crms, FOV, FPRE, ROV, RPRE, Level@Trigger Time +SR, -SR, Period, Freq, +Width, -Width, Rise, Fall, BWidth, +Duty, -Duty, Time@Mid Delay Phase, FRR, FRF, FFR, FFF, LRR, LRF, LFF, Skew Statistics Current, Mean, Min, Max, Stdev, Count Gating Time domain Note: All specifications apply to the unit after a temperature stabilization time of 30 minutes over an ambient temperature range of 23 °C ± 5 °C. (1) On 4-Ch models, Ch1 and Ch2 are interleaved. Half channel operation means that only Ch1 or Ch2 and/or Ch3 or Ch4 is active.
Digital Storage and Mixed Signal Oscilloscopes www.bkprecision.com Serial Trigger I2C Trigger Condition Start, Stop, Restart, No Ack, EEPROM, Address & Data, Data Length Source (SDA/SCL) CH1 to CH4 Data format Binary, Decimal, Hex, ASCII Limit Range EEPROM: =, >, < Data Length EEPROM: 1 byte Address & Data: 1 to 2byte Data Length: 1 to 12byte SPI Trigger Condition Data Source (CS/CLK/Data) CH1 to CH4 Data format Binary, Decimal, Hex, ASCII Data Length 4 to 96 bit Bit Value 0, 1, X Bit Order LSB, MSB UART/RS232 Trigger Condition Start, Stop, Data, Parity Error Source (RX/TX) CH1 to CH4 Data format Binary, Decimal, Hex, ASCII Limit Range =, >, < Data Length 1 byte Data Width 5 bit, 6 bit, 7 bit, 8 bit Parity Check None, Odd, Even Stop Bit 1 bit, 1.5 bit, 2 bit Idle Level High, Low Baud Rate (Selectable) 600/1200/2400/4800/9600/19200/38400/57600 /115200 bit/s Baud Rate (Custom) 300 bit/s to 334000 bit/s CAN Trigger Type All, Remote, ID, ID + Data, Error Source CH1 to CH4 ID STD (11bit), EXT(29bit) Data format Binary, Decimal, Hex, ASCII Data Length 1 to 2 byte Baud Rate (Selectable) 5k/10k/20k/50k/100k/125k/250k/500k/800k/1M bit/s Baud Rate (Custom) 5 kbit/s to 1 Mbit/s LIN Trigger Type Break, Frame ID, ID+Data, Error Source CH1 to CH4 ID 1 byte Data format Binary, Decimal, Hex, ASCII Data Length 1 to 2 byte Baud Rate (Selectable) 600/1200/2400/4800/9600/19200 bit/s Baud Rate (Custom) 300 bit/s to 20 kbit/s Specifications Trigger System Edge Trigger Slope Rising, Falling, Rising & Falling Source CH1 to CH4/EXT/(EXT/5)/AC Line Slope Trigger Slope Rising, Falling Time Range 2 ns to 4.2 s Resolution 1 ns Pulse Width Trigger Polarity +wid, -wid Pulse Width Range 2 ns to 4.2 s Resolution 1 ns Video Trigger Signal Standard NTSC, PAL, 720p/50, 720p/60, 1080p/50, 1080p/60, 1080i/50, 1080i/60, Custom Sync Any, Select Trigger Condition Line, Field Window Trigger Window Type Absolute, Relative Interval Trigger Slope Rising, Falling Time Range 2 ns to 4.2 s Resolution 1 ns Dropout Trigger Timeout Type Edge, State Slope Rising, Falling Time Range 2 ns to 4.2 s Resolution 1 ns Runt Trigger Polarity +wid, -wid Time Range 2 ns to 4.2 s Resolution 1 ns Pattern Trigger Pattern Setting Invalid, Low, High Logic AND, OR, NAND, NOR Time Range 2 ns to 4.2 s Resolution 1 ns
Digital Storage and Mixed Signal Oscilloscopes www.bkprecision.comv011719 Function/Arbitrary Waveform Generator (FG2560) Waveforms Sine, Square, Ramp, Pulse, DC, Noise, Cardiac, Gaus Pulse, Exp Rise Arbitrary 4 Slots for Arbitrary Waveforms Maximum Output Frequency 25 MHz Sample Rate 125 MSa/s Frequency Resolution 1 μHz Frequency Accuracy ±50 ppm Vertical Resolution 14 bits Amplitude Range -1.5 to +1.5 V @ 50 Ω; -3 to +3 V @ 1 MΩ Output Impedance 50 Ω ±2% Protection Short-Circuit Protection Sine Characteristics Frequency 1 μHz to 25 MHz Offset Accuracy (100 kHz) ±(0.3 dB x Offset Setting Value + 1 mVpp) Amplitude flatness ±0.3 dB (100 kHz, 5 Vpp) Spurious (non harmonics) DC to 1 MHz: -60 dBc
1 MHz to 5 MHz: -55 dBc
5 MHz to 25 MHz: -50 dBc
Harmonic distortion DC to 5 MHz: -50 dBc
5 MHz to 25 MHz: -45 dBc
Square/Pulse Characteristics Frequency 1 μHz to 10 MHz Duty Cycle 20% to 80% Rise/Fall Time < 24 ns (10% to 90%) Overshoot (1 kHz, 1 Vpp Typical) < 3% Pulse Width > 50 ns Jitter < 500 ps + 10 ppm Ramp Characteristics Frequency 1 μHz to 300 kHz Linearity (Typical) < 0.1% of Pk-Pk (Typical, 1 kHz, 1 Vpp, 100% Symmetry) Symmetry 0% to 100% (Adjustable) DC Characteristics Offset Range ±1.5 V (50 Ω) ±3 V (High-Z) Accuracy ±(|offset|*1%+3 mV) Noise Characteristics Bandwidth > 25 MHz (-3 dB) Arbitrary Wave Characteristics Frequency 1 μHz to 5 MHz Wave Length 16 kpts Sample Rate 125 MSa/s Serial Decoder (DC2560) Threshold -4.5 to 4.5 div Recorded List 1 to 7 Lines I2C Decoder Signal SCL, SDA Address 7 bit, 10 bit SPI Decoder Signal CLK, MISO, MOSI, CS Edge Select Rising, Falling Idle Level Low, High Bit Order MSB, LSB UART / RS232 Decoder Signal RX, TX Data Width 5, 6, 7, 8 bit Parity Check None, Odd, Even Stop Bit 1, 1.5, 2 bit Idle Level Low, High CAN Decoder Signal CAN_H, CAN_L Source CAN_H, CAN_L, CAN_H-CAN_L LIN Decoder Supported Specification Ver1.3, Ver2.0 Specifications MSO Digital Channels (LA2560/LP2560) Digital Channels 16 Sample Rate 500 MSa/s Memory Depth 14 Mpts/Ch Maximum Input Voltage ± 20 Vpeak Threshold Accuracy ± (3% of threshold setting + 150 mV) Input Dynamic Range ± 10 V Minimum Input Voltage Swing 800 mVpp Input Impedance 100 kΩ || 18 pF Maximum Input Frequency 60 MHz Minimum Detectable Pulse Width 8.3 ns Ch to Ch Skew ± (1 digital sample interval) User Defined Threshold Range ± 3 V in 10 mV steps Threshold Selections TTL, CMOS, LVCMOS3.3, LVCMOS2.5, Custom (-3 to +3 V)