246 RTI-V

www.vishay.com Vishay BCcomponents Revision: 14-Mar-17 1 Document Number: 28422 For technical questions, contact: aluminumcaps1@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Aluminum Electrolytic Capacitors Radial, High Temperature, Low Impedance, High Vibration Capability

FEATURES

  • Very long useful life: 4000 h to 6000 h at 125 °C
  • High stability, high reliability
  • Very low ESR
  • AEC-Q200 qualified
  • Excellent ripple current capability
  • High vibration resistance up to 50 g
  • Polarized aluminum electrolytic capacitors, non-solid electrolyte
  • Radial leads, cylindrical aluminum case, insulated with a blue PET sleeve
  • Charge and discharge proof
  • Material categorization: fo r definitions of compliance please see www.vishay.com/doc?99912

APPLICATIONS

  • Power supplies (SMPS, DC/DC converters) for industrial, automotive, telecommunications and military
  • Smoothing, filtering and buffering MARKING The capacitors are marked (where possible) with the following information:
  • Rated capacitance (in μF)
  • Tolerance on rated capacitance, code letter in accordance with IEC 60062 (M for ± 20 %)
  • Rated voltage (in V)
  • Date code, in accordance with IEC 60062
  • Code indicating factory of origin
  • Logo of manufacturer
  • Upper category temperature (125 °C)
  • Negative terminal identification
  • Series number (246) QUICK REFERENCE DATA DESCRIPTION VALUE Nominal case sizes (Ø D x L in mm) 16 x 20 to 18 x 35 Rated capacitance range, C R 390 μF to 6800 μF Tolerance on CR ± 20 % Rated voltage range, UR 16 V to 63 V Category temperature range -55 °C to +125 °C Endurance test at 125 °C 3000 h to 5000 h Useful life at 125 °C 4000 h to 6000 h Useful life at 40 °C, 1.8 x I R applied 400 000 h Shelf life at 0 V, 125 °C 1000 h Based on sectional specification IEC 60384-4 / EN130300 Climatic category IEC 60068 55 / 125 / 56

146 RTI

140 RTM

125 °C150 RMI high vibration 246 RTI-V SELECTION CHART FOR CR, UR, AND RELEVANT NOMINAL CASE SIZES (Ø D x L in mm) CR (μF) UR (V) 16 25 35 50 63 390 - - - - 16 x 20 470 - - - - 18 x 20 560 - - - - 16 x 25 680 - - - - 18 x 25 - - - - 16 x 31 820 - - - 16 x 20 16 x 35 1000 - - - 18 x 20 18 x 31 - - - 16 x 25 -

www.vishay.com Vishay BCcomponents Revision: 14-Mar-17 2 Document Number: 28422 For technical questions, contact: aluminumcaps1@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 DIMENSIONS in millimeters AND AVAILABLE FORMS Fig. 2 - Form CA: Long leads Fig. 3 - Form CB: Cut leads Fig. 4 - Form TFA: Taped in box (ammopack) Table 1 1200 - - 16 x 20 18 x 25 18 x 35 - - - 16 x 31 - 1500 - - 18 x 20 16 x 35 - 1800 - 16 x 20 16 x 25 18 x 31 - 2200 - - 18 x 25 18 x 35 - - - 16 x 31 - - 2700 16 x 20 18 x 20 16 x 35 - - - 16 x 25 18 x 31 - - 3300 18 x 20 16 x 31 18 x 35 - - 3900 16 x 25 18 x 25 - - - 4700 18 x 25 16 x 35 - - - 16 x 31 18 x 31 - - - 5600 16 x 35 18 x 35 - - - 6800 18 x 31 - - - - SELECTION CHART FOR CR, UR, AND RELEVANT NOMINAL CASE SIZES (Ø D x L in mm) CR (μF) UR (V) 16 25 35 50 63 L F min. min. Ø dØ D Ø D L 4 + 1 F Ø d DIMENSIONS in millimeters, MASS, AND PACKAGING QUANTITIES NOMINAL CASE SIZE Ø D x L CASE CODE Ø d Ø Dmax. Lmax. F MASS (g) PACKAGING QUANTITIES FORM CA FORM CB FORM TFA

www.vishay.com Vishay BCcomponents Revision: 14-Mar-17 3 Document Number: 28422 For technical questions, contact: aluminumcaps1@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Note

  • Unless otherwise specified, all electrical values in Table 2 apply at T amb = 20 °C, P = 86 kPa to 106 kPa, RH = 45 % to 75 % ORDERING EXAMPLE Electrolytic capacitor 246 series, high vibration resistance 4700 μF / 25 V; ± 20 % Nominal case size: Ø 18 mm x 31 mm; Form TFA Table 2 ELECTRICAL DATA SYMBOL DESCRIPTION CR Rated capacitance at 100 Hz, tolerance ± 20 % IR Rated RMS ripple current at 100 kHz, 125 °C IL2 Max. leakage current after 2 min at UR tan  Max. dissipation factor at 100 Hz Z Max. impedance at 100 kHz ELECTRICAL DATA AND ORDERING INFORMATION UR (V) CR 100 Hz (μF) NOMINAL CASE SIZE Ø D x L (mm) IR 100 kHz 125 °C (mA) IL2 2 min (μA) tan  100 Hz Z 100 kHz +20 °C () Z 100 kHz -40 °C () ORDERING CODE BULK PACKAGING TAPED FORM CA FORM CB FORM TFA 2700 16 x 20 1900 435 0.18 0.034 0.204 55272E3 65272E3 35272E3 3300 18 x 20 2000 531 0.20 0.033 0.198 55332E3 65332E3 35332E3 3900 16 x 25 2500 627 0.20 0.024 0.144 55392E3 65392E3 35392E3 4700 18 x 25 2800 755 0.22 0.025 0.150 55472E3 65472E3 35472E3 4700 16 x 31 3000 755 0.22 0.021 0.126 95475E3 95476E3 95473E3 5600 16 x 35 3200 899 0.24 0.018 0.108 55562E3 65562E3 - 6800 18 x 31 3100 1091 0.24 0.022 0.132 55682E3 65682E3 35682E3 1800 16 x 20 1900 453 0.14 0.034 0.204 56182E3 66182E3 36182E3 2700 18 x 20 2000 678 0.16 0.033 0.198 56272E3 66272E3 36272E3 2700 16 x 25 2500 678 0.16 0.024 0.144 96275E3 96276E3 96273E3 3300 16 x 31 3000 828 0.18 0.021 0.126 56332E3 66332E3 36332E3 3900 18 x 25 2800 978 0.18 0.025 0.150 56392E3 66392E3 36392E3 4700 16 x 35 3200 1178 0.20 0.018 0.108 56472E3 66472E3 - 4700 18 x 31 3100 1178 0.20 0.022 0.132 96475E3 96476E3 96473E3 5600 18 x 35 3100 1403 0.22 0.019 0.114 56562E3 66562E3 - 1200 16 x 20 1900 423 0.12 0.034 0.204 50122E3 60122E3 30122E3 1500 18 x 20 2000 528 0.12 0.033 0.198 50152E3 60152E3 30152E3 1800 16 x 25 2500 633 0.12 0.024 0.144 50182E3 60182E3 30182E3 2200 18 x 25 2800 773 0.14 0.025 0.150 50222E3 60222E3 30222E3 2200 16 x 31 3000 773 0.14 0.021 0.126 90225E3 90226E3 90223E3 2700 16 x 35 3200 948 0.14 0.018 0.108 50272E3 60272E3 - 2700 18 x 31 3100 948 0.14 0.022 0.132 90275E3 90276E3 90273E3 3300 18 x 35 3100 1158 0.16 0.019 0.114 50332E3 60332E3 - 820 16 x 20 1650 413 0.10 0.047 0.282 51821E3 61821E3 31821E3 1000 18 x 20 1800 503 0.10 0.039 0.234 51102E3 61102E3 31102E3 1000 16 x 25 2100 503 0.10 0.031 0.186 91105E3 91106E3 91103E3 1200 18 x 25 2400 603 0.10 0.030 0.180 51122E3 61122E3 31122E3 1200 16 x 31 2550 603 0.10 0.027 0.162 91125E3 91126E3 91123E3 1500 16 x 35 2800 753 0.10 0.022 0.132 51152E3 61152E3 - 1800 18 x 31 2700 903 0.10 0.026 0.156 51182E3 61182E3 31182E3 2200 18 x 35 3000 1103 0.12 0.022 0.132 51222E3 61222E3 - 390 16 x 20 1250 249 0.10 0.075 0.450 58391E3 68391E3 38391E3 470 18 x 20 1500 299 0.10 0.055 0.330 58471E3 68471E3 38471E3 560 16 x 25 1800 356 0.10 0.048 0.288 58561E3 68561E3 38561E3 680 18 x 25 2100 431 0.10 0.041 0.246 58681E3 68681E3 38681E3 680 16 x 31 2200 431 0.10 0.036 0.216 98685E3 98686E3 98683E3 820 16 x 35 2500 520 0.10 0.029 0.174 58821E3 68821E3 - 1000 18 x 31 2400 633 0.10 0.032 0.192 58102E3 68102E3 38102E3 1200 18 x 35 2600 759 0.10 0.029 0.174 58122E3 68122E3 -

www.vishay.com Vishay BCcomponents Revision: 14-Mar-17 4 Document Number: 28422 For technical questions, contact: aluminumcaps1@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Table 3 Fig. 5 - Vibration profile Table 4 CAPACITANCE (C) Fig. 6 - Typical multiplier of capacitance at 100 Hz as a function of temperature (C0 = C at 20 °C) Fig. 7 - Typical multiplier of capacitance as a function of frequency at 20 °C (C0 = C at 100 Hz) EXTENDED VIBRATION SPECIFICATIONS PARAMETER PROCEDURE REQUIREMENTS Vibration specifications From 10 g to 50 g No visible damage; no leakage of electrolyte; marking legible C/C: ± 5 % with respect to initial measurements Vibration frequency range 10 Hz to 2 kHz Vibration profile

  • Constant sinus sweep
  • 3 d i r e c t i o n s
  • 8 h per direction ADDITIONAL ELECTRICAL DATA PARAMETER CONDITIONS VALUE Voltage Surge voltage U s  1.15 x UR Reverse voltage Urev  0.5 V Current Leakage current After 2 min at U R IL2  0.01 CR x UR + 3 μA Inductance Equivalent series inductance (ESL) Case Ø D  16 mm Typ. 18 nH Resistance Equivalent series resistance (ESR) Calculated from tan  max. and CR (see Table 2) ESR = tan /2 f CR 00 . 511 . 5 2 . 0 Acceleration (g) f (kHz) High vibration specification AEC-Q200 Standard vibration specification 1.2 C 0.8 1.1 1.0 0.9 -60 120 100806040200-20-40 140 T (°C) 1.2 C 0.0 1.0 0.8 0.6 10 1000 100 100 000 f (Hz) 0.2 0.4 10 000

www.vishay.com Vishay BCcomponents Revision: 14-Mar-17 5 Document Number: 28422 For technical questions, contact: aluminumcaps1@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 EQUIVALENT SERIES RESISTANCE (ESR) Fig. 8 - Typical multiplier of ESR at 100 Hz as a function of temperature (ESR0 = ESR at 20 °C) Fig. 9 - Typical multiplier of ESR at 20 °C as a function of frequency (ESR0 = ESR at 100 Hz) IMPEDANCE (Z) Fig. 10 - Typical multiplier of impedance at 100 kHz as a function of temperature (Z0 = Z at 20 °C) Fig. 11 - Typical impedance Z at 20 °C as a function of frequency Fig. 12 - Typical impedance Z at 20 °C as a function of frequency 100 ESR ESR0 0.1 -60 120 100806040200-20-40 140 T (°C) ESR ESR0 10 1000 100 100 000 f (Hz) 10 000 100 Z 0.1 -60 120 100806040200-20-40 140 T (°C) 100 Z (Ω) 0.01 0.1 10 1000 100 100 000 f (Hz) 10 000 1800 µF , 35 V, 16 x 25 3300 µF , 35 V, 18 x 35 1000 Z (Ω) 0.01 0.1 10 1000 100 100 000 f (Hz) 10 000 100 Curve 1: 560 µF , 63 V, 16 x 25 Curve 2: 680 µF , 63 V, 16 x 31 Curve 3: 1000 µF , 63 V, 18 x 31

www.vishay.com Vishay BCcomponents Revision: 14-Mar-17 6 Document Number: 28422 For technical questions, contact: aluminumcaps1@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 RIPPLE CURRENT AND USEFUL LIFE Table 5 Note

  • Multiplier of useful life code: MBC242 Fig. 13 - Multiplier of useful life as a function of ambient temperature and ripple current load ENDURANCE TEST DURATION AND USEFUL LIFE AS A FUNCTION OF CASE SIZE NOMINAL CASE SIZE Ø D x L (mm) CASE CODE ENDURANCE AT 125 °C (h) USEFUL LIFE AT 125 °C (h) 16 x 20 19a 3000 4000 16 x 25 19 3000 5000 16 x 31 20 4000 6000 16 x 35 21 5000 6000 18 x 20 1820 3000 4000 18 x 25 1825 3000 5000 18 x 31 1831 4000 6000 18 x 35 22 5000 6000 3.8 3.7 3.6 3.5 3.4 3.3 3.2 3.0 2.8 2.6 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.5 0.0 3.1 40 50 60 70 80 90 100 11 0 T amb (°C) 120 130 MBC242 3.9 4.0 4.1 4.2 4.3 Lifetime multiplier (1) IA IR 6.0 4.0 2.0 1.5 1.0 3.0 400 100 8.0 200 IA = Actual ripple current at 100 kHz IR = Rated ripple current at 100 kHz, 125 °C (1) Useful life at 125 °C and IR applied; see Table 6

www.vishay.com Vishay BCcomponents Revision: 14-Mar-17 7 Document Number: 28422 For technical questions, contact: aluminumcaps1@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Table 6 Table 7 Statements about product lifetime are based on calculations and in ternal testing. They should only be interpreted as estimation s. Also due to external factors, the lifetime in the field application may deviate from the calculated lifetime. In general, nothing stated herein shall be construed as a guarantee of durability. MULTIPLIER OF RIPPLE CURRENT (IR) AS A FUNCTION OF FREQUENCY UR (V) FREQUENCY (Hz) 50 100 300 1000 3000 10 000 100 000 IR MULTIPLIER TEST PROCEDURES AND REQUIREMENTS TEST PROCEDURE (quick reference) REQUIREMENTSNAME OF TEST REFERENCE Endurance IEC 60384-4 / EN130300 subclause 4.13 T amb = 125 °C; UR applied; for test duration see Table 3 C/C: ± 15 % tan  1.3 x spec. limit Z 2 x spec. limit IL2  spec. limit Useful life CECC 30301 subclause 1.8.1 Tamb = 125 °C; UR and IR applied; for test duration see Table 3 C/C: ± 30 % tan  3 x spec. limit Z 3 x spec. limit IL2  spec. limit no short or open circuit total failure percentage:  1 % Shelf life IEC 60384-4 /  EN130300 subclause 4.17 T amb = 125 °C; no voltage applied; 1000 h after test: U R to be applied for 30 min, 24 h o 48 h before measurement C/C: ± 15 % tan  1.3 x spec. limit Z 3 x spec. limit IL2  spec. limit

www.vishay.com Vishay Revision: 08-Feb-17 1 Document Number: 91000 Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA AR E SUBJECT TO CHANGE WITH OUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employee s, and all persons acting on it s or their behalf (collectivel y, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of th e products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product , (ii) any and all liability, including without limitation specia l, consequential or incidental damages, and (iii) any and all implied warranties, includ ing warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applicatio ns are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular applic ation. It is the customer’s responsibility to validate tha t a particular product with the prope rties described in the product sp ecification is suitable for use in a particular application. Parameters provided in datasheets and / or specifications may vary in different ap plications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s term s and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay product s not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain writ ten terms and conditions rega rding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is gran ted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. © 2017 VISHAY INTERTECHNOLOGY, INC. ALL RIGHTS RESERVED