Technical content
00813-0100-2460, Rev CA May 2020 Rosemount™ 2460 System Hub for tank gauging systems Transfers tank gauging data to Rosemount TankMaster™, Host and DCS systems ■ Ensure fast data update rate ■ Serves up to 64 tanks ■ Benefit from scalable options for all system sizes ■ Get real-time inventory calculations with API standard net volumes ■ Get flexible and configurable multiple port connectivity ■ Achieve instrument and system redundancy ■ Enable other vendor emulation by bringing in data from gauges such as Enraf®, Varec®, and Sakura
Efficient update of vital online tank data The Rosemount 2460 System Hub is a data concentrator that continuously polls and stores data from field devices such as radar level gauges, pressure and temperature devices. Measured and calculated data from one or more tanks is communicated via the Rosemount 2410 Tank Hub to the system hub buffer memory. Whenever a request is received, the system hub can immediately send data from a group of tanks to a TankMaster PC or a host. The system hub also supports connection of other tank gauging instruments such as TankRadar™ Pro and TankRadar Rex gauges. In addition, it can be used to connect devices from other vendors, such as Honeywell® Enraf, Whessoe, etc. Figure 1: System Overview Rosemount TankRadar FBM 218 0 Ext. pwr RS-232 USB Tx Rx Lo - GAIN - Hi On - TERM - Off C A HE I H F B D G J L K M A. TankMaster PC B. Host System C. Modem D. Modbus RTU E. Rosemount 2460 System Hub F. Modbus® RTU/TCP G. Fieldbus H. Rosemount 2410 Tank Hub I. Tankbus J. Rosemount 2240S Multi-input Temperature Transmitter K. Rosemount 5900S Radar Level Gauge L. Rosemount 2230 Graphical Field Display M. Rosemount 3051S Pressure Transmitter
Contents
2 Emerson.com/Rosemount
Configurable multiple port connectivity The Rosemount 2460 has eight slots for communication interface boards. These boards can be individually configured for communication with hosts or field devices. The Rosemount 2460 supports a number of host communication interface standards such as Ethernet, TRL2, RS485, and RS232. For field communciation TRL2 and RS485 are supported, as well as other standards such as Enraf BPM and Digital Current Loop (Whessoe). Modbus TCP communication to host One of the system hub’s three Ethernet ports is used for Modbus TCP connection to host systems. By simply connecting the system hub to the existing LAN network, communication over Ethernet is established: ■ Easy access, no special converters required ■ Fast communication ■ No need for dedicated cabling ■ Can be connected to TankMaster or other hosts User-defined Modbus mapping The Rosemount 2460 can easily be integrated into existing hosts as it can be configured to match the existing value mapping of the current system. It provides flexibility when replacing legacy devices as it can be set up to match the old device without configuring the host system. Figure 2: User-Defined Modbus Mapping C A B D A. TankMaster PC(1) B. Rosemount 2460 System Hub C. Existing legacy HMI(2) D. Existing DCS (2) (1) Standard connection to Rosemount 2460. (2) User-defined Modbus mapping set-up to match the configuration of the legacy data collector. May 2020 Rosemount 2460 Emerson.com/Rosemount 3
Improved system reliability with redundancy The system hub can provide redundancy for critical operations by using two identical devices. The primary system hub is in active mode and the other one is in passive mode. If the primary unit stops working properly the secondary unit is activated and a failure message is sent to TankMaster (or a DCS system). Redundancy can be utilized for some or all equipment in the system from the control room to the field devices. Redundancy is supported on field level as well by using two field devices connected to the same tank for hot redundancy of field values. It can be a Rosemount 5900 2-in-1, two separate Rosemount 5900 devices, or two separate devices of different types. Field port redundancy is supported where two field ports can be connected in a ring network where one acts as a hot backup. All field ports are available for redundancy. It is also possible to use redundancy individually on ports 1-2, ports 3-4, or ports 5-6. Figure 3: Redundancy B AA C C D D B A. TankMaster client PCs B. Switch C. TankMaster servers D. Rosemount 2460 System Hubs Rosemount 2460 May 2020 4 Emerson.com/Rosemount
Seamless integration of gauges from other vendors Replace your old tank management system with Rosemount TankMaster by connecting the system hub to the existing field devices, such as Enraf, Whessoe, or Varec. Rosemount TankMaster can seamlessly replace an existing inventory management system, still being able to communicate with the field devices in use. This often enables a better update rate than before. Emulation also enables the step-by-step modernization of a tank farm by replacing old field devices with Rosemount 5900 level gauges, temperature devices, and one or several tank hubs. Any Modbus field device that communicates via RS485 Modbus RTU can be integrated into Rosemount 2460. Up to three device types can be defined. Figure 4: Integration of Gauges From Other Vendors A C E B D A. TankMaster PC B. Rosemount 2410 Tank Hub C. Rosemount 2460 System Hub D. Rosemount 5900S Level Gauge E. Gauges in an existing system from another vendor May 2020 Rosemount 2460 Emerson.com/Rosemount 5
Real-time inventory calculations include gross and net volumes as well as mass calculations, according to current API tables (6, 54, 24, 60, A-D) and ASTM D4311. Tank Capacity Tables (5000 strapping points per tank/table) are supported for cylindrical and spherical tanks. Net Standard Volume can be calculated at a user-specified reference temperature for specific tables. Figure 5: Inventory Calculation A B C I J L K D E F H G A. Level B. Tank Capacity Table C. Total Observed Volume D. Gross Observed Volume E. Volume Correction Factor, CTPL (VCF) F. Gross Standard Volume G. Sediment & Water H. Net Standard Volume I. Free Water Volume J. Volume K. Temperature L. TReference Rosemount 2460 May 2020 6 Emerson.com/Rosemount
Ordering information
The Rosemount 2460 System Hub transfers real time tank gauging data from field devices to the Rosemount TankMaster Inventory Management Software and/or a Host/DCS system. The system hub has eight configurable ports for host or field device communication. It supports system redundancy and emulation of other vendor devices. VIEW PRODUCT > Table 1: Rosemount 2460 System Hub Ordering Information Model Product description
2460 System Hub
Capacity(1)(2) 1 1-16 tanks 4 1-48 tanks 6 1-64 tanks Firmware S Standard
1 Inventory calculation, 1-16 tanks
4 Inventory calculation, 1-48 tanks
6 Inventory calculation, 1-64 tanks
Redundancy/Remote access (Ethernet)
0 None
R(3)(4) Redundancy Modbus mapping S Standard G(5) User-defined Modbus mapping (Enables customized mapping for host communication.) Port 1, field communication (serial port)(6) R TRL2 Modbus E Enraf Bi-phase Mark GPU G GPE (Digital Current Loop) P GPE (RS485) H Whessoe WM 550/660 (Digital Current Loop) Y Whessoe WM 660 (RS485) L(7)(8) L&J Tankway V(7)(8) Varec Mark/Space May 2020 Rosemount 2460 Emerson.com/Rosemount 7
Table 1: Rosemount 2460 System Hub Ordering Information (continued) U(9) Sakura V1, MDP, BBB T Tokyo Keiso, TIC
4 RS485 Modbus
Port 2, field communication (serial port)(6) 0(10) None R TRL2 Modbus E Enraf Bi-phase Mark GPU G GPE (Digital Current Loop) P GPE (RS485) H Whessoe WM 550/660 (Digital Current Loop) Y Whessoe WM 660 (RS485) L(7)(8) L&J Tankway V(7)(8) Varec Mark/Space U(9) Sakura V1, MDP, BBB T Tokyo Keiso, TIC Port 3, field communication (serial port)(6) 0(10) None R TRL2 Modbus E Enraf Bi-phase Mark GPU G GPE (Digital Current Loop) P GPE (RS485) H Whessoe WM 550/660 (Digital Current Loop) Y Whessoe WM 660 (RS485) L(7)(8) L&J Tankway V(7)(8) Varec Mark/Space U(9) Sakura V1, MDP, BBB T Tokyo Keiso, TIC Port 4, field communication (serial port)(6) 0(10) None R TRL2 Modbus E Enraf Bi-phase Mark GPU G GPE (Digital Current Loop) P GPE (RS485) H Whessoe WM 550/660 (Digital Current Loop) Rosemount 2460 May 2020 8 Emerson.com/Rosemount
Table 1: Rosemount 2460 System Hub Ordering Information (continued) Y Whessoe WM 660 (RS485) L(7)(8) L&J Tankway V(7)(8) Varec Mark/Space U(9) Sakura V1, MDP, BBB T Tokyo Keiso, TIC Port 5, field or host communication (serial port)(6) 00(10) None FR TRL2 Modbus, field communication FE Enraf Bi-phase Mark GPU, field communication FG GPE (Digital Current Loop), field communication FP GPE (RS485), field communication FH Whessoe WM 550/660 (Digital Current Loop), field communication FY Whessoe WM 660 (RS485), field communication FL(7)(8) L&J Tankway, field communication FV(7)(8) Varec Mark/Space, field communication FU(9) Sakura V1, MDP, BBB FT Tokyo Keiso, TIC F4 RS485 Modbus (Fieldbus) H8(11) Enraf CIU 858 emulation (RS485) HR TRL2 Modbus, host communication H4 RS485 Modbus, host communication Port 6, field or host communication (serial port)(6) 00(10) None FR TRL2 Modbus, field communication FE Enraf Bi-phase Mark GPU, field communication FG GPE (Digital Current Loop), field communication FP GPE (RS485), field communication FH Whessoe WM 550/660 (Digital Current Loop), field communication FY Whessoe WM 660 (RS485), field communication FL(7)(8) L&J Tankway, field communication FV(7)(8) Varec Mark/Space, field communication FU(9) Sakura V1, MDP, BBB FT Tokyo Keiso, TIC F4 RS485 Modbus, field communication H8(11) Enraf CIU 858 emulation (RS485), host communication May 2020 Rosemount 2460 Emerson.com/Rosemount 9
Table 1: Rosemount 2460 System Hub Ordering Information (continued) HR TRL2 Modbus, host communication H4 RS485 Modbus, host communication Port 7, host communication (serial port) 00(10) None TR TRL2 Modbus communication to TankMaster T2 RS232 Modbus communication to TankMaster T4 RS485 Modbus communication to TankMaster HE(11) Enraf CIU 858 emulation (RS232) H8(11) Enraf CIU 858 emulation (RS485) HR TRL2 Modbus communication to host/DCS H2 RS232 Modbus communication to host/DCS H4 RS485 Modbus communication to host/DCS Port 8, host communication (serial port) TR TRL2 Modbus communication to TankMaster T2 RS232 Modbus communication to TankMaster T4 RS485 Modbus communication to TankMaster OPC host communication (Ethernet)
00 None
Modbus TCP host communication (Ethernet) MT TankMaster TCP connection. Two TankMaster clients can connect. M1(12)(5) 1 Modbus TCP client M5(12)(5) 1-5 Modbus TCP clients Power supply P 100-250 VAC 50/60 Hz, 24-48 VDC Custody transfer type approval(13) R OIML R85 edition 2008 A CMI (Czech Republic) C PTB Eich (Germany) I Ministero (Italy) L LNE (France) N NMi (The Netherlands) O ONML (Algeria) T ANM (Tunisia) 10 Emerson.com/Rosemount
Table 1: Rosemount 2460 System Hub Ordering Information (continued) Housing A Aluminum (polyurethane-covered), IP 65 Cable/conduit connections G Metal cable glands (M20 x1.5 and M25 x1.5) Includes: ■ 2 pcs M25 plugs ■ 7 pcs M20 plugs ■ 2 pcs M25 glands ■ 9 pcs M20 glands
1 NPT adapters (½ -14 NPT and ¾ -14 NPT) Includes:
■ 2 pcs M25 plugs ■ 7 pcs M20 plugs ■ 2 pcs ¾-14 NPT adapters ■ 9 pcs ½-14 NPT adapters 2 Metal plugs (M20 x 1.5 and M25 x1.5) Includes: ■ 2 pcs M25 plugs ■ 7 pcs M20 plugs Extra Options (include with selected model number) Tag plate ST Engraved SST tag plate Conformance certificate Q1 Printed copy of certificate of conformance Extended warranty(14) WR3 3-year limited warranty WR5 5-year limited warranty Typical model number: 2460 1 S 0 S R R R R FR FR TR TR 00 00 P R A 1 0 WR3 (1) Maximum number of tanks depends on selected field ports configuration. (2) Depending on device type and application, the number of devices per tank, or number of tanks per device, may differ. (3) Dual Rosemount 2460 System Hub redundancy requires two system hubs with identical model codes. For redundant systems with emulation,consult factory for technical guidance. (4) This option is required to be able to use field port redundancy and/or field device redundancy. Field port redundancy is only possible for TRL/2 and RS485 ports, where the same interface must be used on each pair. The capacity of the Rosemount 2460 is reduced when using field port redundancy. (5) When using Modbus TCP in combination with user-defined Modbus mapping, the same Modbus mapping will be used for all clients. In this case, TankMaster cannot be used. (6) See Table 2 for maximum number of devices connected to each field port. (7) Not supported for redundant system hubs (Redundancy option code R). (8) External power supply is required for powering the bus. (9) Only one protocol can be used per port. (10) Empty ports will not be enabled for use. To activate an empty port after delivery, a port upgrade must be ordered. (11) Emulation of Enraf CIU 858 for connection to existing host system or service/configuration tool. (12) A redundant TankMaster system requires two clients when TankMaster is connected via Modbus TCP . (13) Requires Rosemount 5900S Radar Level Gauge and Rosemount 2410 Tank Hub with corresponding Custody transfer type approval. May 2020 Rosemount 2460 Emerson.com/Rosemount 11
(14) Standard warranty is 18 months from delivery. Rosemount 2460 May 2020 12 Emerson.com/Rosemount
Communication/configuration specifications Number of tanks Each Rosemount 2460 can be configured for up to 64 tanks. The actual number of tanks depends on the electrical interface and field port configuration. For more information, see Table 2. Note that each Rosemount 5900S Radar Level Gauge with 2-in-1 functionality corresponds to two tanks. Number of devices per field port Table 2 lists the maximum number of devices that can be connected to each Rosemount 2460 field port. Examples of devices are Rosemount 2410, Rosemount TankRadar Pro, and legacy devices, such as Rosemount TankRadar Rex and Rosemount TankRadar TRL2. Table 2: Number of Devices Interface Maximum number of devices connected to each field port RS485(1) 16 TRL2(2) 8 Enraf BPM 10 Digital Current Loop 0-20 mA (DCL)(3) 10(4) L&J 10(5) Varec 10(5) (1) Devices such as E+H NRF590 Tank Side Monitor (TSM), devices using TSM Modbus mapping, Whessoe, GPE, SI-6290/7000, Wärtsilä 1146, and user-defined Modbus devices are supported. (2) Devices such as Rosemount 2410 Tank Hub, Rosemount TankRadar Rex, Rosemount TankRadar Pro, TRL2 gauges, and DAU are supported. (3) Devices such as Whessoe and GPE are supported. (4) Up to 32 devices are supported when using external power. (5) In certain situations, more than 10 devices may work. Contact Emerson Automation Solutions/Tank Gauging Service Department for advice. Number of ports Interface Number of ports Modem(1) 8 Ethernet(2) 3 USB(2) 1 SD(2) 1 (1) For more information, see Table 4 and Table 3. (2) For more information, see Table 6. Modem ports can be configured for either field or host communication according to the model code. For more information, see Table 5. Hosts See Table 4 and Table 5. May 2020 Rosemount 2460 Emerson.com/Rosemount 13
Rosemount 2160/2165 emulation Host protocol, supporting the Rosemount 2160/2165 Field Communication Unit input register mapping. Enables the replacement of Rosemount 2160/2165 without re-programming the host. The maximum number of tanks is reduced to 32 when using 2160 emulation. Digital communication protocols Table 3: Serial Field Communication Ports (1-6) Supported devices Protocol Electrical interface Baud rate Port Rosemount 2410,TankRadar Rex gauges (with SDAU), IDAU, TankRadar Pro, and TankRadar TRL2 gauges Modbus RTU TRL2 4800 1-6 Rosemount 2410 RS485 (2-wire) 150-38400 Enraf 811, 813, 854, 873, 877, 894, 970, 971, 973, and TOI-B(1) GPU Enraf Bi-phase Mark 1200/2400 GPE 31422, 31423 GPE 20 mA Digital Current Loop 150-2400 RS485 150-38400 Whessoe 1315, 1143 WM 550 20 mA Digital Current Loop 150-2400 WM 660 20 mA Digital Current Loop 150-2400 RS485 150-38400 L&J 1500 XL, MCG 2000, L&J MCG 1600 L&J Tankway L&J Tankway 300-4800 Varec 1800, 1900 Varec Mark/Space Varec Mark/Space 70/250 E+H NRF590 Tank Side Monitor Modbus RS485 150-38400 User-defined Modbus devices(2) LTD (Level, Temperature, Density) SI LTD (Level, Temperature, Density) Whessoe/ Wärtsilä 1146 Tokyo Keiso Tokyo Keiso Tokyo Keiso 2400 Sakura Sakura V1 Sakura MDP Sakura 9600 (1) Enraf 990 uses TOI-B for measurement data. (2) Fully configurable up to three device types. Rosemount 2460 May 2020 14 Emerson.com/Rosemount
Table 4: Host Communication Ports (5-8) Supported devices Protocol Electrical interface Baud rate Port TankMaster Modbus RTU TRL2 4800 5-8 RS485 (2-wire) 150-38400 5-8(1) RS485 4-wire) 7-8(1) RS232 7-8 Modbus TCP Ethernet N/A Eth1 Other hosts (DCS, SCADA etc.) Modbus RTU TRL2 4800 5-7 RS485 (2-wire) 150-38400 5-7(1) RS485 (4-wire) 7(1) RS232 7 Enraf CIU 858 emulation(2) GPU RS485 (2-wire) 150-38400 5-7(1) RS485 (4-wire) 7(1) RS232 7 (1) Configurable termination by hardware switch. (2) One Rosemount 2460 can replace multiple Enraf CIU 858 devices by replying to more than one separate addresses. Table 5: Port Configuration Options Ports 1 2 3 4 5 6 7 8 Alternative 6+2 (standard) Field Port Field Port Field Port Field Port Field Port Field Port Host Port Host Port Alternative 5+3 Field Port Field Port Field Port Field Port Field Port Host Port Host Port Host Port Alternative 4+4 Field Port Field Port Field Port Field Port Host Port Host Port Host Port Host Port Table 6: Additional Interfaces Electrical interface Description Ethernet 1 (ETH 1)(1)(2) Modbus TCP connection to host system Ethernet 2 (ETH 2)(2) Connected to redundant system hub Ethernet 3 (ETH 3)(2) Used for accessing the web interface via a web browser for advanced configuration and service USB 2.0(3) USB memory stick for logging diagnostic data SD(3) SD card for logging diagnostic data (1) When connecting the system hub to the local LAN network, make sure the connection is secure to prevent unauthorized access. (2) CAT 5 or 6 cable is recommended. (3) FAT32 file system. May 2020 Rosemount 2460 Emerson.com/Rosemount 15
Figure 6: Typical Configuration of a Rosemount 2460 System Hub A I F J J K L M O G CE H N D B E A. TankMaster B. USB RS232 C. Modem D. Ethernet (Modbus TCP), RS232, RS485 E. TRL2, RS485 F. DCS/Other hosts (TRL2, RS485, RS232) G. Rosemount 2460 System Hub H. Modbus RTU/TCP I. Other hosts J. Field devices K. Tankbus L. Rosemount 2410 Tank Hub M. Primary bus: TRL2, RS485 N. TRL2, RS485, other vendors O. Secondary bus: Enraf, Whessoe and others, HART 4-20 mA analog output/input Rosemount 2460 May 2020 16 Emerson.com/Rosemount
Figure 7: Typical Redundant Configuration A F G C H D B E A. TankMaster B. Modem C. Rosemount 2460 System Hub, primary D. Rosemount 2460 System Hub, secondary E. Redundancy control signal F. Field devices G. Tankbus H. Rosemount 2410 Tank Hub May 2020 Rosemount 2460 Emerson.com/Rosemount 17
Nine M20 x 1.5 (female thread) Two M25 x 1.5 (female thread) Electrical interface See Table 4, Table 3 and Table 6. Cable size Power: 0.75 to 2.1 mm² (18-14 AWG) Bus: 0.5 to 2.5 mm² (20-14 AWG) depending on communication interface Built-in mains fuses T1.6 A Backup battery 3V CR 1632 lithium Mechanical specifications Housing material Polyurethane-covered die-cast aluminum Installation Wall mounted by four screws. For more information, see Dimensional drawings. Weight 7 kg (15 lbs) Rosemount 2460 May 2020 18 Emerson.com/Rosemount
Environmental specifications Temperature limits Ambient temperature -40 to 70 °C (-40 to 158 °F) Storage temperature -40 to 80 °C (-40 to 176 °F) Humidity limits 0-100% relative humidity Ingress protection IP 65 Additional specifications Metrology sealing possibility Yes Write protection Yes, via software configuration and/or hardware switch. May 2020 Rosemount 2460 Emerson.com/Rosemount 19
Rev 3.1 European directive information The most recent revision of the EU Declaration of Conformity can be found at Emerson.com/Rosemount. Ordinary location certification As standard, the Rosemount 2460 System Hub has been examined and tested to determine that the design meets the basic electrical, mechanical, and fire protection requirements by a nationally recognized test laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). Certificate 2735155 Standards CAN/CSA-C22.2 No. 61010-1-12; UL Std. No. 61010-1 (3rd Edition); Markings Rated 24-48 V dc, 100-250 V ac, 20 W, 50/60 Hz; Ambient rated -40 to +70 °C Electromagnetic compatibility compliance FCC This device complies with Part 15 of the FCC Rules. Standards FCC 47 CFR Part 15B, 15.107 Conducted emission class A, 15.109 Radiated Emission class A Custody transfer certifications OIML custody transfer Certificate R85-2008-SE-11.01 Rosemount 2460 May 2020 20 Emerson.com/Rosemount
Figure 8: Rosemount 2460 System Hub 158 (6.2) 246 (9.7) 265 (10.4) 348 (13.7) Dimensions are in millimeters (inches). May 2020 Rosemount 2460 Emerson.com/Rosemount 21
Figure 9: Rosemount 2460 System Hub 374 (14.7) A 36 (1.4) 87 (3.4) 186 (7.3) 465 (18.3) Ø 12.5 (0.5) x4 Ø 6.5 (0.3) x4 A. 474 (18.7) with lid maximum open Dimensions are in millimeters (inches). Rosemount 2460 May 2020 22 Emerson.com/Rosemount
Emerson.com/Rosemount 23
Rev. CA May 2020 Global Headquarters and Europe Regional Office Tank Gauging Emerson Automation Solutions Box 150 (Visiting address: Layoutvägen 1) SE-435 23 Mölnlycke Sweden +46 31 337 00 00 +46 31 25 30 22 Sales.RTG@Emerson.com North America Regional Office Tank Gauging Emerson Automation Solutions
6005 Rogerdale Road
Houston, TX 77072, USA +1 281 988 4000 or +1 800 722 2865 Sales.RTG.HOU@Emerson.com Latin America Regional Office Emerson Automation Solutions
1300 Concord Terrace, Suite 400
Sunrise, FL 33323, USA +1 954 846 5030 +1 954 846 5121 RMTLAContactUS@Emerson.com Asia Pacific Regional Office Emerson Automation Solutions
1 Pandan Crescent
+65 6777 8211 +65 6777 0947 Specialist-OneLevel.RMT- AP@Emerson.com Middle East and Africa Regional Office Emerson Automation Solutions Emerson FZE P.O. Box 17033 Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates +971 4 8118100 +971 4 8865465 RTGMEA.Sales@Emerson.com Linkedin.com/company/Emerson-Automation-Solutions Twitter.com/Rosemount_News Facebook.com/Rosemount Youtube.com/user/RosemountMeasurement ©2020 Emerson. All rights reserved. Emerson Terms and Conditions of Sale are available upon request. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount is a mark of one of the Emerson family of companies. All other marks are the property of their respective owners.