240GT54 HOLLAND | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 6
Technical content
Amphenol All rights reserved DS-60-1950 100120 v5 800-677-2288 | abs-go.com 240GT54/nrg240GT54 – 240A Dual-Feed Combination Fuse Panel Power: 5/4 Position GMT/TPA Fuse Panel The Amphenol 240GT54/nrg240GT54 combination fuse panels are 240A dual-feed and provide 5/5 GMT fuse positions and 4/4 TPA fuse or circuit breaker positions. Our 240GT54/nrg240GT54 panels feature ±12/±24/±48V operating voltages to serve both legacy and “next-gen” network applications. Engineered into a standard 1RU footprint, with circuits that support up to 20A GMT fuses and 50A TPA fuses or 60A breakers in each position, providing ample capacity for distribution to a broad range of components. The panel is available in standard terminal block outputs or connectorized outputs. This platform provides front access to alarm enable/disable switch configuration for uninstalled TPA fuse or breaker locations. Also featured are front LED indicators for power/fuse alarms, monitoring status, rear connections for form C relay alarms, and optional nrgSMART connections. Each of the 240A feeds provide power for up to five GMT and four TPA or breakers output positions. The panel includes removable 1RU TPA fuse holders. These 1RU TPA fuse holders feature an ergonomic front grip for easy removal, sliding top cover to protect the fuse from above, and red alarm plunger to indicate a failed fuse. Circuit breakers are an optional accessory and can be installed with a protective cover to protect against unintended on or off switching. Circuit breaker covers are included with all panels. Field replaceable GMT fuses are available from 18/100A to 20A. TPA fuses are available from 5A to 50A per position. Breakers are available from 5A to 60A per position. The panel supports universal voltages (±12VDC to ±48VDC). Primary Benefits
- Universal voltage (±12VDC, ±24VDC and ±48VDC) enables standardization on a single part number for multiple voltages
- Up to 50A fuses or 60A breakers for distribution to a variety of network elements
- UL and NEBS compliant to ensure industry-standard safety and functional requirements
- Form C relay contacts provide reliable alarm connections
- Integrated designation card holder for simple circuit identification
- Fail alarm LEDs indicate fuse and power failures
- Clear, flame-retardant polycarbonate cover (94V-0) protects input and output power connections and wiring from damage
- Either vertical feed inputs and staggered output terminal blocks to facilitate waterfall cable management, horizontal feed inputs and output connectors that speed-up installation and allow cables to exit straight back from the panel, or vertical feed inputs and output connectors that allow input cables to be routed directly from above and speed up installation of outputs Fig. 1: nrg240GT54-SENS Front View Fig. 2: 240GT54 Rear View
Amphenol All rights reserved DS-60-1950 100120 v5 800-677-2288 | abs-go.com 240GT54/nrg240GT54 – 240A Dual-Feed Combination Fuse Panel
- Optional Individual Circuit Monitoring provides high accuracy, 100% passive monitoring
- Collect voltage and current for both feed and output circuit
- Collect temperature using optional nrgTEMP probes
Applications
- Wireless
- Central office
- Co-location
- Remote sites
- Secondary distribution
Ordering Information
GMT/TPA Combination Fuse Panel Part Number 240A Dual-Feed, 5/4 Panel, Vertical Inputs, Output Terminal Blocks 240GT54 240A Dual-Feed, 5/4 Panel, Horizontal Inputs, Connectorized Outputs (Connectors purchased separately) 240GT54-C 240A Dual-Feed, 5/4 Panel, Vertical Inputs, Connectorized Outputs (Tie Bar and Connectors purchased separately) 240GT54-SC nrgSMART Circuit Monitoring, Controller, 240A Dual-Feed, 5/4 Panel, Vertical Inputs, Output Terminal Blocks nrg240GT54-CTRL nrgSMART Circuit Monitoring, Sensor, 240A Dual-Feed, 5/4 Panel, Vertical Inputs, Output Terminal Blocks nrg240GT54-SENS nrgSMART Circuit Monitoring, Controller, 240A Dual-Feed, 5/4 Panel, Horizontal Inputs, Connectorized Outputs (Connectors purchased separately) nrg240GT54-CTRL-C nrgSMART Circuit Monitoring, Sensor, 240A Dual-Feed, 5/4 Panel, Horizontal Inputs, Connectorized Outputs (Connectors purchased separately) nrg240GT54-SENS-C nrgSMART Circuit Monitoring, Controller, 240A Dual-Feed, 5/4 Panel, Vertical Inputs, Connectorized Outputs (Tie Bar and Connectors purchased separately) nrg240GT54-CTRL-SC nrgSMART Circuit Monitoring, Sensor, 240A Dual-Feed, 5/4 Panel, Vertical Inputs, Connectorized Outputs (Tie Bar and Connectors purchased separately) nrg240GT54-SENS-SC Fig. 3: 240GT54-C Rear View Fig. 4: nrg240GT54-CTRL Front View
Amphenol All rights reserved DS-60-1950 100120 v5 800-677-2288 | abs-go.com 240GT54/nrg240GT54 – 240A Dual-Feed Combination Fuse Panel Accessories (Purchased Separately) Part Number Blanking Cover: Single, Covers unused fuse holder positions 150203+03 1RU Circuit Breaker Puller 307491
4 Post Mounting Bracket Kit: 22”-36” Brackets, Mounting Hardware (requires Tie Bar, -C Versions
only) 307622 Tie Bar Kit: Connectorized, Rear Mount Tie Bar, Mounting Hardware (-SC Versions only) 307661 nrgSMART Temperature Sensor, ACC, 6ft nrgTemp Replacement Components Part Number Replaceable Alarm Card 307608 Replaceable Alarm Card, nrgSMART 307710 Replaceable Controller Card, nrgSMART 400822 Replaceable Sensor Card, nrgSMART 307607 1RU TPA Fuse Holder 307492 Dummy GMT fuse 132748 Breaker Cover Kit: Slimline, Cover, Hardware 307689 19” Mounting Bracket Kit: 2x 19” Brackets, Mounting Hardware PMTG19 23” Mounting Bracket Kit: 2x 23” Brackets, Mounting Hardware PMTG23 Connectors (Purchased Separately) Part Number P40 Connector Kit: TPA, 8-6 AWG, Plug, Retainer, 2x Contacts 150326 P40 Connector Kit: TPA, 12-10 AWG, Plug, Retainer, 2x Contacts 150325 P40 Replaceable Contact: TPA, 8-6 AWG, Single Contact 150333 P40 Replaceable Contact: TPA, 12-10 AWG, Single Contact 150334 P24 Connector Kit: GMT, 12-10 AWG, Plug, Retainer, 2x Contacts 150336 P24 Connector Kit: GMT, 14-12 AWG, Plug, Retainer, 2x Contacts 150342 P24 Replaceable Contact: GMT, 12-10 AWG, Single Contact 150343 P24 Replaceable Contact: GMT, 14-12 AWG, Single Contact 150344 Crimp Tool: 14-6 AWG, Daniels, M300BT 150793 Crimp Tool Locator: Universal, Daniels, UH2-5 150794 Contact Removal Tool: P40 Connector 150797 GMT Fuses Part Number 18/100A 130781 1/4A 100151 1/2A 004001 3/4A 004008 1A 100991 1-1/3A 004006 1-1/2A 004011 2A 004002 2-1/2A 130783 3A 004012 3-1/2A 130782 Stud Input/Lug Output Connectorized/Horizontal Input “-C” Connectorized/Stud Input “-SC”
Amphenol All rights reserved DS-60-1950 100120 v5 800-677-2288 | abs-go.com 240GT54/nrg240GT54 – 240A Dual-Feed Combination Fuse Panel 4A 004013 5A 004014 7-1/2A 004010 10A 004015 12A 102287 15A 102288 20A 127240 20A with cover 131340 TPA Fuses Part Number 5A, 170VDC 124818 10A, 170VDC 124819 15A, 170VDC 124820 20A, 170VDC 124821 25A, 170VDC 125244 30A, 170VDC 122734 40A, 170VDC 122738 50A, 170VDC 122739 Circuit Breakers Part Number 5A, standard delay, UL489, without cover 149710 10A, standard delay, UL489, without cover 149711 15A, standard delay, UL489, without cover 149712 20A, standard delay, UL489, without cover 149713 25A, standard delay, UL489, without cover 149714 30A, standard delay, UL489, without cover 149715 40A, standard delay, UL489, without cover 149716 50A, standard delay, UL489, without cover 149718 60A, standard delay, UL489, without cover 149719
Amphenol All rights reserved DS-60-1950 100120 v5 800-677-2288 | abs-go.com 240GT54/nrg240GT54 – 240A Dual-Feed Combination Fuse Panel Specifications Inputs Specifications Voltage range (nominal voltage) ±12VDC, ±24VDC and ±48VDC Max. input load rating 240A @ 45°C per panel (De-rated to 160A @ 65°C) Short circuit withstand rating 5000A Nominal power loss at full load Less than 45W per side @11,520W full load per side (240A x 48V); 240A @ 45°C per panel Percentage of full power dissipation at nominal voltage Less than 0.5% Max. input interrupt device 125% of panel rating (for 240A rated feeds) Optional (Standard and -SC versions): Vertical input terminal studs (with Keps nuts and flat washers) for dual-hole compression lugs Two pairs of 3/8-16 studs on 1" centers per terminal [max. lug width of 1.15" (29.2 mm)]. Torque nut (using 9/16" or 15 mm socket) to 150 in/lb. (~17 N•m), max. Optional (-C Versions): Horizontal input terminal landings (with Keps nuts, flat washers, and bolts) for dual-hole compression lugs Two pairs of 3/8” holes on 5/8”-1" centers per terminal [max. lug width of 1.5" (38.1 mm)]. Torque bolt and nut (using 9/16" or 15 mm sockets) to 150 in/lb. (~17 N•m), max. Input wire size 2/0 AWG to 350 MCM Grounding Specifications Earth GND terminal bolts (with spring washers and flat washers) for dual-hole compression lug Three sets of 1/4-20 threaded holes on 5/8" centers. [max. lug width of .50" (12.7 mm)]. Torque bolts (using 7/16" or 12 mm socket) to 50 in/lb. (5.5 N•m), max. Ground wire size #14 AWG to #4 AWG Outputs Specifications Output fuse 20A GMT fuse 50A TPA fuse 60A circuit breaker Output load 16A continuous GMT fuse 40A continuous TPA fuse 48A continuous circuit breaker Minimum short circuit interrupt rating 5000A Optional (Standard Versions): Terminal blocks, single- hole compression lugs (.9 N•m), max. GMT fuse 8, #10-32 screws [max. lug width of .50" (12.7)]. Torque screw to 20 in/lb. (2.3 N•m), max. TPA fuse or circuit breaker Optional (Standard Versions): Output wire size, single- hole compression lug #22 AWG to #6 AWG, GMT fuse #14 AWG to #4 AWG, TPA fuse or circuit breaker Optional (-C and -SC Versions): Connectors (purchased separately) 10, P24 connector plugs, latching, safe touch, GMT fuse 8, P40 connector plugs, latching, safe touch, TPA fuse or circuit breaker Optional (-C and -SC Versions): Output wire size, connectors #14 AWG to #10 AWG, GMT fuse #12 AWG to #6 AWG, TPA fuse or circuit breaker GMT fuses Cooper Bussmann and Littelfuse TPA fuses Cooper Bussmann Circuit breaker AIRPAX 1U Series Alarms Specifications Alarm relay contacts 2A @ 30 VDC; 0.6A @ 60 VDC Max. alarm card power rating @12V: 18mA (0.22W) @24V: 20mA (0.48W); @48V: 30mA (1.44W) Alarm wire size #24 AWG, typical (#26 to #20 AWG) Terminals Wire wrap or mates with TE Connectivity 3-640428-3
Amphenol All rights reserved DS-60-1950 100120 v5 800-677-2288 | abs-go.com 240GT54/nrg240GT54 – 240A Dual-Feed Combination Fuse Panel Dimensions Specifications 240GT54/ nrg240GT54 Height: Depth: Width: 240GT54-C/nrg240GT54-C Height: Depth: Width: 240GT54-SC/nrg240GT54-SC Height: Depth: Width: 1.75" (44 mm) 13.5" (344 mm) 17.0" (432 mm) without brackets 19” and 23” brackets included with panel 1.75" (44 mm) 18.7" (475 mm) without tie bar 21.9" (557 mm) with tie bar 17.0" (432 mm) without brackets 19” and 23” brackets included with panel Tie bar included with panel Cable-end connectors not included with panel 1.75" (44 mm) 13.5" (344 mm) without tie bar 17.0” (432mm) with tie bar 17.0" (432 mm) without brackets 19” and 23” brackets included with panel Tie bar and cable-end connectors not included with panel Weights Specifications 240GT54/nrg240GT54 240GT54-C/nrg240GT54-C 240GT54-SC/nrg240GT54-SC 12.4 lb. Unpopulated / 14.2 lb. Populated 15.0 lb. Unpopulated / 16.8 lb. Populated 12.4 lb. Unpopulated / 14.2 lb. Populated Compliance Specifications UL Listed NEBS Level 3 Voltage Sensor (nrgSMART model only) Specifications Sensor accuracy -19.99 to +19.99V: ± 0.3V -20V to -60V: ± 0.1V +20V to +60V: ± 0.1V Voltage measurement range -60 to +60 VDC NOTE:
- Voltage measurement may be slightly different than at input terminal blocks due to the voltage drop within the panel.
- Sensors are factory calibrated and do not require user adjustment. Current Sensor (nrgSMART model only) Specifications Precision / accuracy ±5% precision, ±0.25A accuracy Example: 40A current, will measure 40A ± (40A*5%) ± 0.25A = 40A ± 2.0A ± 0.25A = 37.75A to 42.25A Communication (nrgSMART model only) Specifications nrgOS minimum required version nrgOS 4.1.0 nrgNET communication protocol Proprietary serial protocol used to communicate between panels and controller nrgNET connector Removable 5-pin connector with screw down terminals nrgNET connector functions nrgNET IN from the Controller or upstream nrgSMART panel, nrgNET OUT to downstream nrgSMART panel