Axial Lead and Cartridge Fuses 422 www.littelfuse.com Designed to METI Standard 5 x 20 mm Medium-Acting Fuse 232 Series

  • Designed to Japanese Standard JIS C6575.
  • Available in Cartridge, Axial and Radial Lead Format.
  • Available in ratings of 1A to 10A.
  • RoHS compliant and Lead-Free version available, add XP suffix to standard catalog number ELECTRICAL CHARACTERISTICS: % of Ampere Opening Rating Time 130% 1 hour, Minimum 160% 1 hour, Maximum 200% 2 minutes, Maximum 1000% .01 sec, Minimum INTERRUPTING RATING: 1A-5A 10,000A @ 125VAC, 0.7-0.8 power factor 6.3A-10A 300A @ 125VAC, 0.7-0.8 power factor 100 amperes at 250 VAC, 0.7-0.8 power factor ORDERING INFORMATION: RoHS compliant and Lead-Free version available, add XP suffix to standard catalog number Nominal Nominal Catalog Ampere Voltage Resistance Melting I 2t Number Rating Rating* Cold Ohms A 2 Sec 0232 001. 1 125/250 0.0957 1.41 0232 1.25 1.25 125/250 0.0707 4.22 0232 01.6 1.6 125/250 0.0567 7.14 0232 002. 2 125/250 0.0385 8.47 0232 02.5 2.5 125/250 0.0297 14.25 0232 003. 3 125/250 0.0257 17.65 0232 3.15 3.15 125/250 0.0235 22.55 0232 004. 4 125/250 0.018 38.75 0232 005. 5 125/250 0.0145 58.25 0232 06.3 6.3 125/250 0.0105 92.85 0232 008. 8 125/250 .0076 187.5 0232 010. 10 125/250 .0061 298.5 *To order 125V rating, add part number suffix X125 ENVIRONMENTAL SPECIFICATIONS: Operating temperature: -55˚C to 125˚C Thermal Shock: MIL-STD-202F Method 107G, Test Condition B: (5 cycles –65°C to +125°C) Vibration: MIL-STD-202F Method 201A Humidity: MIL-STD-202F Method 103B, Test Condition A. high relative humidity (95%) and elevated temperature (40°C) for 240 hours. Salt Spray: MIL-STD-202F Method 101D, Test Condition B PHYSICAL SPECIFICATIONS: Material: Body: Glass Cap: Nickel Plated Brass Leads: Tin Plated Copper Terminal Strength: MIL-STD-202F Method 211A, Test Condition A Solderability: Reference IEC 60127 Second Edition 2003-01 Annex A Product Marking: Cap 1: current and voltage rating. Cap 2: Agency approval markings. Packaging: Available in Bulk (v=5, H=100, M=1000 pcs/pkg) or on Tape/Reel (MRET1=1000 pcs/reel). RoHS Pb

Axial Lead and Cartridge Fuses 423www.littelfuse.com 11AXIAL LEAD AND CARTRIDGE FUSES 5 x 20 mm Medium-Acting Fuse 232 Series 0232 000 0232 000 XW 0232 000 XE 20+0.5 5.1+0.6 5.2+0.1 -0.2 5.1+0.6 0.65* 40 22.5 MAX 5.8 MAX All dimensions in mm 20+0.5 20.64+2.0 0.64 25.0+0.5 Notes: * Ratings above 6.3A have 0.8 mm dia lead

1 For RoHS compliant parts

add suffix 'XP'

2 For RoHS compliant parts

add suffix 'P' Agency Approvals Agency Approvals Ampere Range Certificate No. SU05001-2001 1A – 10A (125V) 1A – 10A Certificate No. Cartridge NBK010702-E10480 A 1A – 5A 125V 10,000A NBK290502-E10480 C 6.3A – 10A 125V 300A Leaded NBK010702-E10480 B 1A – 5A 125V 10,000A NBK290502-E10480 E 6.3A – 10A 125V 300A RoHS 0.001 0.01 0.1 11 0 100 1000 100 1000 10000 CURRENT IN AMPERES TIME IN SECONDS 1.25A 1.6A 2.5A 3.15A 6.3A 10A Average Time Current Curves Pb