MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 1/22 Multiplex Transmission System MULTI-TRANSMISSION MODULE Functions & Features

  • Miniaturized, plug-in, socket-mounted version of the multiplex transmission system
  • Analog, digital or pulse string signals transmitting via twisted-pair cable
  • No master station required
  • Easy expansion up to 256 modules (2000 points) Typical Applications
  • Input and output processing for computer systems and telemetering systems
  • Complete system compatibility with DLA1 and other units, utilizing the same communication protocol (2.83) 144 (5.67) (3.15) mm (inch) SA1 1234567 890 1234567 890 SA2 ! RUN PWR PU-2 ❑ MODEL: 22LA1–3[1]–[2]

ORDERING INFORMATION

  • Code number: 22LA1–3[1]-[2] Specify a code from below for each [1] and [2] (e.g. 22LA1-3A4-K) TRANSMISSION MEDIA 3: Twisted-pair cable for small-scale system [1] I/O SECTION A1: Di 24 points (BCD) A2: Di 16 points (BCD) A4: Di 8 points C1: Do 24 points (BCD) C2: Do 16 points (BCD) C7: Do 8 points (relay) C8: Do 8 points (photo MOSFET relay) E5: Di 4 + Do 4 points (relay) E6: Di 4 + Do 4 points (photo MOSFET relay) G3: Ai 8 points G4: Ai 4 points M3: Ao 8 points M4: Ao 4 points P4: Pi 4 points U4: Po 4 points [2] POWER INPUT AC Power K: 85 – 132 V AC (Operational voltage range 85 – 132 V, 47 – 66 Hz) L: 170 – 264 V AC (Operational voltage range 170 – 264 V, 47 – 66 Hz) DC Power S: 12 V DC (Operational voltage range 12 V ±10 %, ripple 10 %p-p max.) R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) GENERAL SPECIFICATIONS Construction: Plug-in Connection Power input: M3.5 screw terminals Field I/O: M3.5 screw terminals or 26-pin connector Transmission: Euro type connector terminal Housing material: Flame-resistant resin (black) Isolation: I/O to transmission to reset (provided only for pulse I/O type) to power Terminator: Incorporated (remove jumper pin with those modules not located at the end of transmission line) Power indicator: Red LED turns ON in normal conditions; OFF when the voltage level becomes low. RUN indicator: Red LED turns ON when the selfdiagnosis proves normal, OFF in an abnormality. ■ RUN Output: Contact opens when the self-diagnosis detects an abnormality. 125 V AC @ 0.5 A (cos ø = 1) 30 V DC @ 0.5 A (resistive load) Maximum switching voltage: 250 V AC or 125 V DC Maximum switching power: 62.5 VA or 60 W Minimum load: 10 mV DC @ 1 mA Mechanical life: 5 × 107 cycles (rate 300/min.) 108 cycles (rate 180/min.) Self-diagnosis Communication: The receiver modules detect loss of communication and wire break. CPU: Watch-dog timer Memory: Sum check Power voltage: Detects when the voltage supply to the CPU drops. COMMUNICATION Communication: 2-wire, half-duplex Transmission: conform to RS-422, EIA

MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 2/22 Transmission speed: 125 kbps Data encoding: SDLC Control procedure: NRZ Protocol: SIN-NET (M-System's) Error check: CRC Cable: CPEV-0.9 dia. Transmission distance: 500 meters INSTALLATION Power consumption

  • AC: Approx. 5 VA
  • DC: 24 V or 12 V ±10 % (ripple 10 %p-p max.) approx. 4.4 W (180 mA with 24 V) with 8-point relays at the maximum load Operating temperature: -5 to + 50°C (23 to 122°F) Operating humidity: 30 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Surface or DIN rail Weight: 400 g (0.88 lbs) PERFORMANCE Permissible power failure duration: ≤ 10 msec. Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 500 V AC @ 1 minute (I/O to transmission to reset*)

1500 V AC @ 1 minute

(power to I/O or transmission or reset*)

1500 V AC @1 minute (FG to each section)

*Reset terminals are provided only for pulse string I/O type. DESCRIPTIONS ■ RUN Output (LED) Operation Input unit The LED for the Input Units (A1, A2, A4, G3, G4 and P4) turns ON when the network is on-line. When there is an abnormality in the network, the LED turns OFF. The network is reconfigured after an abnormality. Output unit The LED for the Output Units (C1, C2, C7, C8, M3, M4 and U4) turns ON when the network is on-line and the unit receives data from the corresponding Input Unit. When there is an abnormality in the network or there is no data receiving, the LED turns OFF. When the I/O Units are connected via the 22LS1 (DLS), once the LED turns ON, it remains ON regardless of the state of Input Unit or the leased circuit. When the Output Unit is connected to the DLC (for setting data from the DLC), the LED turns ON once the Output Unit receives normal data, and remains ON even when there is no data update. I/O Unit The LED's operating conditions for the I/O Unit (E5 and E6) are combined ones of Input Unit and Output Unit. Caution: When the network is reconfigured e.g. by noise interference, the RUN LED and output for all units on the network turn briefly OFF until they are turned ON after the reconfiguration is complete. ■ Station Number (Address) A) 1 input unit and X output units: Match the address for input and output modules. The input data can be output at several modules. B) I/O mixed modules: Set an even number and a consecutive number for the 2 corresponding modules.

MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 3/22 C) Computer interface: Set address numbers to correspond with the computer as I/O module. ■ Transmission Time Integrate all the transmission time for each process input (or I/O-mixed) module in the system.

  • Contact input, BCD, 16 points (A2) 1.5 msec.
  • Contact input 8 points (A4) 1.5 msec.
  • Contact I/O each 4 points (E5, E6) 1.5 msec.
  • Analog input 8 points (G3) 12.0 msec.
  • Analog input 4 points (G4) 6.0 msec.
  • Pulse input 4 points (P4) 6.0 msec. An analog module does not transmit all its signals in serial but does 1 point per each cycle. For example, when 1 contact input module (8 points) and 1 analog input module (4 points) are connected, 8 point contact signal and 1 point analog signal are transmitted in turn. One cycle time is therefore calculated as: 4 points × 1.5 msec. + 6 msec. = 12 msec. This method is beneficial for giving a priority to contact signals which vary rapidly. ■ Transmission line configuration The multi-drop transmission line containing 22LA1 and DLx units should meet the following conditions. Contact M-System's sales office or representatives when designing. A) 10 kilometers at maximum in total system. B) Line consists only of 22LA1 modules : one multitransmission line can contain at the maximum of 16 units within the total C) 22LA1 modules plus link adapter (model: DAL4) : DAL4 units can expand the total distance. (8 DAL4 units max.) D) 22LA1 modules plus DL x units : the total distance of a section consists of 22LA1 modules is less than 500 meters. The 22LA1

1 A L 2 21 A L 2 2

modules can be connected to DLx units via a DLx-7 unit. (Eight DLx-7 units max.) distance of 500 m.

MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 4/22 EXTERNAL VIEW ■ 22LA1-3A1, -3C1 A B C D E F LINE RT RUN RUN PWR SA1 SA2 Power Indicator LED RUN Indicator LED Station No. Setting Rotary Switches Transmission Line Jumper (Terminator) RUN Output Contact

  • Pin Assignments 33 34 1 234-pin Connector ■ 22LA1-3A2, -3C2 A B C D E F LINE RT RUN RUN PWR SA1 SA2 Power Indicator LED RUN Indicator LED Station No. Setting Rotary Switches Transmission Line Jumper (Terminator) RUN Output Contact Modular Jack 26-pin Connector
  • Pin Assignments ■ STANDARD TYPE A B C D E F LINE RT RUN RUN PWR SA1 SA2 Power Indicator LED RUN Indicator LED Station No. Setting Rotary Switches Transmission Line Jumper (Terminator) RUN Output Contact Contact I/O Indicator LED* *Deleted with analog I/O modules. LED5 through 8 deleted with the 22LA1-3P4 or -3U4. Modular Jack EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) ■ 22LA1-3A1, -3C1 12 5614 11 110 15 80 (3.15) 50 (1.97) 60 (2.36) 72 (2.83)
  • When mounting, no extra space is needed between units. 103 (4.06) (.55) 80 (3.15) (.79) 35.4 (1.39) 7.8 (.31) 2–4.5 (.18) dia. MTG HOLE 25 (.98) deep 14–M3.5 SCREW CLAMP (top & bottom) DIN RAIL 35mm wide

MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 5/22 ■ 22LA1-3A2, -3C2 80 (3.15) 50 (1.97) 80 (3.15) (.79) 35.4 (1.39) 60 (2.36) 72 (2.83) 7.8 (.31) CLAMP (top & bottom) DIN RAIL 35mm wide2–4.5 (.18) dia. MTG HOLE 25 (.98) deep 14–M3.5 SCREW

  • When mounting, no extra space is needed between units. 12 5614 11 110 15 103 (4.06) (.63) ■ STANDARD TYPE 80 (3.15) 50 (1.97) 80 (3.15) (.79) 35.4 (1.39) 60 (2.36) 72 (2.83) 7.8 (.31) CLAMP (top & bottom) DIN RAIL 35mm wide2–4.5 (.18) dia. MTG HOLE 25 (.98) deep 14–M3.5 SCREW
  • When mounting, no extra space is needed between units. 12 5614 11 110 15 103 (4.06) min. (.47) SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Isolation Base Socket A Transceiver Circuit Control CircuitB C D E F U(+) V(–) POWER Ry TERMINATING RESISTORJUMPER PIN* TWISTED PAIR RUN OUTPUT GROUNDING FG I / O *When the unit is located at the end of transmission line via twisted-pair cable (= no cross-wiring), short across the terminals C – D with the jumper pin (or wire) provided with the unit. Remove the jumper pin for the one not located at the end.

MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 6/22 CONTACT INPUT MODULE (BCD) MODEL: 22LA1–3A1–[1]

  • Code number: 22LA1–3A1-[1] Specify a code from power input options for [1] (e.g. 22LA1-3A1-K) GENERAL SPECIFICATIONS Input connector: 34-pin connector (OMRON XG4A-3434) Usable connector type: OMRON XG4M-3430-T, XG5M-343x-N) Usable cover type: OMRON XG5S-3422 The special cable (model: MCN34), Connector Terminal Block (model: CNT) are available. INPUT SPECIFICATIONS Input: TTL level (5V-CMOS level); open collector or dry contact (saturation voltage ≤ 1 V, sink current 1 mA); negative logic ■ Starion No.: Match the number of input and output modules PERFORMANCE Multi-transmission time: 1.5 msec. Input read time: 50 msec. CONNECTOR PIN ASSIGNMENT PIN NO. ASSIGNMENT PIN NO. ASSIGNMENT 1 1 × 10 0 (B 0 ) 21 1 × 10 5 (B 20 ) 2 2 × 10 0 (B 1 ) 22 2 × 10 5 (B 21 ) 3 4 × 10 0 (B 2 ) 23 4 × 10 5 (B 22 ) 4 8 × 10 0 (B 3 ) 24 8 × 10 5 (B 23 ) 5 1 × 10 1 (B 4 ) 25 COM 6 2 × 10 1 (B 5 ) 26 COM 7 4 × 10 1 (B 6 ) 27 No connection 8 8 × 10 1 (B 7 ) 28 No connection 9 1 × 10 2 (B 8 ) 29 No connection 10 2 × 10 2 (B 9 ) 30 No connection 11 4 × 10 2 (B 10 ) 31 No connection 12 8 × 10 2 (B11) 32 No connection 13 1 × 10 3 (B 12 ) 33 No connection 14 2 × 10 3 (B 13 ) 34 No connection 15 4 × 10 3 (B 14 ) 16 8 × 10 3 (B 15 ) 17 1 × 10 4 (B 16 ) 18 2 × 10 4 (B 17 ) 19 4 × 10 4 (B 18 ) 20 8 × 10 4 (B 19 ) B0 – B 23 are inputs. TERMINAL CONNECTION (INPUT) Base Socket INPUT CONNECTOR Isolation

MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 7/22 CONTACT INPUT MODULE (BCD) MODEL: 22LA1–3A2–[1]

  • Code number: 22LA1–3A2-[1] Specify a code from power input options for [1] (e.g. 22LA1-3A2-K) GENERAL SPECIFICATIONS Input connector: 26-pin connector (OMRON XG4A-2934) Usable connector type: OMRON XG4M-2630-T, XG5M-263x-N) Usable cover type: OMRON XG5S-2612 The special cable (model: MCN26), Connector Terminal Block (model: CNT) are available. INPUT SPECIFICATIONS Input: TTL level (5V-CMOS level); open collector or dry contact (saturation voltage ≤ 1 V, sink current 1 mA); negative logic ■ Starion No.: Match the number of input and output modules PERFORMANCE Multi-transmission time: 1.5 msec. Input read time: 50 msec. CONNECTOR PIN ASSIGNMENT PIN NO. ASSIGNMENT PIN NO. ASSIGNMENT 1 1 × 10 0 (B 0 ) 17 COM 2 2 × 10 0 (B 1 ) 18 COM 3 4 × 10 0 (B 2 ) 19 No connection 4 8 × 10 0 (B 3 ) 20 No connection 5 1 × 10 1 (B 4 ) 21 No connection 6 2 × 10 1 (B 5 ) 22 No connection 7 4 × 10 1 (B 6 ) 23 COM 8 8 × 10 1 (B 7 ) 24 COM 9 1 × 10 2 (B 8 ) 25 No connection 10 2 × 10 2 (B 9 ) 26 No connection 11 4 × 10 2 (B 10 ) 12 8 × 10 2 (B11) 13 1 × 10 3 (B 12 ) 14 2 × 10 3 (B 13 ) 15 4 × 10 3 (B 14 ) 16 8 × 10 3 (B 15 ) B0 – B 15 are inputs. TERMINAL CONNECTION (INPUT) Base Socket INPUT CONNECTOR Isolation

MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 8/22 CONTACT INPUT MODULE (Di 8 points) MODEL: 22LA1–3A4–[1]

  • Code number: 22LA1–3A4-[1] Specify a code from power input options for [1] (e.g. 22LA1-3A4-K) INPUT SPECIFICATIONS Input: Dry contact, 8 points Commons: All negatives Sensing: 12 V DC ≥ 3 mA at ON ≤ 1 mA at OFF ■ Starion No.: Match the number of input and output modules PERFORMANCE Multi-transmission time: 1.5 msec. Input read time: 5 msec. per 8 points TERMINAL CONNECTION (INPUT) Base Socket COM(–) COM(–) Di 6 Di 7 Di 8 Di 5 COM(–) Di 4 Di 3 Di 2 Di 1 V 12V Italic fi gures indicate LED No. on the front panel.

MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 9/22 CONTACT OUTPUT MODULE (BCD) MODEL: 22LA1–3C1–[1]

  • Code number: 22LA1–3C1-[1] Specify a code from power input options for [1] (e.g. 22LA1-3C1-K) GENERAL SPECIFICATIONS Output connector: 34-pin connector (OMRON XG4A-3434) Usable connector type: OMRON XG4M-3430-T, XG5M-343x-N) Usable cover type: OMRON XG5S-3422 The special cable (model: MCN34), Connector Terminal Block (model: CNT) are available. When driving an inductive load, external protection is recommended. INPUT SPECIFICATIONS Hold Input: TTL level (5V-CMOS level); open collector or dry contact (saturation voltage ≤ 1 V, sink current 1 mA); negative logic OUTPUT SPECIFICATIONS Output: Open collector Maximum collector-emitter voltage: 30 V DC Maximum collector current: 30 mA Saturation voltage: ≤ 1.1 V; negative logic DAV output (Data available): Same level as for the output code; negative logic ■ Starion No.: Match the number of input and output modules PERFORMANCE Output time: ≤ 20 msec. CONNECTOR PIN ASSIGNMENT PIN NO. ASSIGNMENT PIN NO. ASSIGNMENT 1 1 × 10 0 (B 0 ) 21 1 × 10 5 (B 20 ) 2 2 × 10 0 (B 1 ) 22 2 × 10 5 (B 21 ) 3 4 × 10 0 (B 2 ) 23 4 × 10 5 (B 22 ) 4 8 × 10 0 (B 3 ) 24 8 × 10 5 (B 23 ) 5 1 × 10 1 (B 4 ) 25 COM 6 2 × 10 1 (B 5 ) 26 COM 7 4 × 10 1 (B 6 ) 27 DAV 8 8 × 10 1 (B 7 ) 28 HOLD 9 1 × 10 2 (B 8 ) 29 No connection 10 2 × 10 2 (B 9 ) 30 No connection 11 4 × 10 2 (B 10 ) 31 No connection 12 8 × 10 2 (B11) 32 No connection 13 1 × 10 3 (B 12 ) 33 No connection 14 2 × 10 3 (B 13 ) 34 No connection 15 4 × 10 3 (B 14 ) 16 8 × 10 3 (B 15 ) 17 1 × 10 4 (B 16 ) 18 2 × 10 4 (B 17 ) 19 4 × 10 4 (B 18 ) 20 8 × 10 4 (B 19 ) B0 – B 23 are inputs, DAV is an output, and HOLD is an input. TERMINAL CONNECTION (OUTPUT) Base Socket OUTPUT CONNECTOR Isolation

MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 10/22 TIMING CHART DAV DATA OUTPUT approx. 10 ms approx. 1 ms HOLD When the HOLD input signal is valid ("L"), the DAV output is not provided and the data output is held at the value before that.

MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 11/22 CONTACT OUTPUT MODULE (BCD) MODEL: 22LA1–3C2–[1]

  • Code number: 22LA1–3C2-[1] Specify a code from power input options for [1] (e.g. 22LA1-3C2-K) GENERAL SPECIFICATIONS Output connector: 26-pin connector (OMRON XG4A-2634) Usable connector type: OMRON XG4M-2630-T, XG5M-263x-N) Usable cover type: OMRON XG5S-2612 The special cable (model: MCN26), Connector Terminal Block (model: CNT) are available. When driving an inductive load, external protection is recommended. INPUT SPECIFICATIONS Hold Input: TTL level (5V-CMOS level); open collector or dry contact (saturation voltage ≤ 1 V, sink current 1 mA); negative logic OUTPUT SPECIFICATIONS Output: Open collector Maximum collector-emitter voltage: 30 V DC Maximum collector current: 30 mA Saturation voltage: ≤ 1.1 V; negative logic DAV output (Data available): Same level as for the output code; negative logic ■ Starion No.: Match the number of input and output modules PERFORMANCE Output time: ≤ 20 msec. CONNECTOR PIN ASSIGNMENT PIN NO. ASSIGNMENT PIN NO. ASSIGNMENT 1 1 × 10 0 (B 0 ) 17 COM 2 2 × 10 0 (B 1 ) 18 COM 3 4 × 10 0 (B 2 ) 19 No connection 4 8 × 10 0 (B 3 ) 20 No connection 5 1 × 10 1 (B 4 ) 21 DAV 6 2 × 10 1 (B 5 ) 22 HOLD 7 4 × 10 1 (B 6 ) 23 COM 8 8 × 10 1 (B 7 ) 24 COM 9 1 × 10 2 (B 8 ) 25 No connection 10 2 × 10 2 (B 9 ) 26 No connection 11 4 × 10 2 (B 10 ) 12 8 × 10 2 (B11) 13 1 × 10 3 (B 12 ) 14 2 × 10 3 (B 13 ) 15 4 × 10 3 (B 14 ) 16 8 × 10 3 (B 15 ) B0 – B 15 are inputs, DAV is an output, and HOLD is an input. TERMINAL CONNECTION (OUTPUT) Base Socket OUTPUT CONNECTOR Isolation TIMING CHART DAV DATA OUTPUT approx. 10 ms approx. 1 ms HOLD When the HOLD input signal is valid ("L"), the DAV output is not provided and the data output is held at the value before that.

MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 12/22 RELAY OUTPUT MODULE (Do 8 points) MODEL: 22LA1–3C7–[1]

  • Code number: 22LA1–3C7-[1] Specify a code from power input options for [1] (e.g. 22LA1-3C7-K) OUTPUT SPECIFICATIONS Output: Relay contact, 8 points Commons: Per 4 points, 2 points, 2 points Contact rating: 125 V AC @ 0.5 A (cos ø =1) 30 V DC @ 0.5 A (resistive load) Max. switching voltage: 250 V AC or 125 V DC Max. switching power: 62.5 VA or 60 W Min. load: 10 mV DC @ 1mA Mechanical life: 5 × 107 cycles (rate 300/min.) 108 cycles (rate 180/min.) When driving an inductive load, external protection is recommended. ■ Starion No.: Match the number of input and output modules PERFORMANCE Output time OFF to ON: 8 msec. per 8 points ON to OFF: 3 msec. per 8 points TERMINAL CONNECTION (OUTPUT) Base Socket Do 6 Do 7 Do 8 COM311 Do 5 COM1 COM2 Do 4 Do 3 Do 2 Do 1 Italic figures indicate LED No. on the front panel.

MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 13/22 PHOTO MOSFET RELAY OUTPUT MODULE (Do 8 points) MODEL: 22LA1–3C8–[1]

  • Code number: 22LA1–3C8-[1] Specify a code from power input options for [1] (e.g. 22LA1-3C8-K) OUTPUT SPECIFICATIONS Output: Photo MOSFET relay, 8 points Commons: Per 4 points, 2 points, 2 points Contact rating: 125 V AC/DC @ 50 mA (resistive load) Max. ON resistance: 50 Ω ■ Starion No.: Match the number of input and output modules PERFORMANCE Output time OFF to ON: 8 msec. per 8 points ON to OFF: 3 msec. per 8 points TERMINAL CONNECTION (OUTPUT) Base Socket Do 6 Do 7 Do 8 COM3 11 Do 5 COM1 COM2 Do 4 Do 3 Do 2 Do 1 Italic figures indicate LED No. on the front panel.

MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 14/22 CONTACT I/O MODULE (Di & Do each 4 points; relay contact output) MODEL: 22LA1–3E5–[1]

  • Code number: 22LA1–3E5-[1] Specify a code from power input options for [1] (e.g. 22LA1-3E5-K) INPUT SPECIFICATIONS Input: Dry contact, 4 points Commons: Per 4 points Sensing: 12 V DC ≥ 3 mA at ON ≤ 1 mA at OFF OUTPUT SPECIFICATIONS Output: Relay contact, 4 points Commons: Per 2 points Contact rating: 125 V AC @ 0.5 A (cos ø = 1) 30 V DC @ 0.5 A (resistive load) Max. switching voltage: 250 V AC or 125 V DC Max. switching power: 62.5 VA or 60 W Min. load: 10 mV DC @ 1 mA Mechanical life: 5 × 107 cycles (rate 300/min.) 108 cycles (rate 180/min.) When driving an inductive load, external protection is recommended. ■ Starion No.: set an even number to one unit and a consecutive odd number to the paired unit. (e.g. "02" and PERFORMANCE Multi-transmission time: 1.5 msec. Input read time: 5 msec. per 4 points Output time OFF to ON: 8 msec. per 4 points ON to OFF: 3 msec. per 4 points I/O TERMINAL CONNECTION Base Socket COM3 COM2 Do 2 Do 3 Do 4 Do 1 COM(–) Di 4 Di 3 Di 2 Di 1 V 12V Italic fi gures indicate LED No. on the front panel.

MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 15/22 CONTACT I/O MODULE (Di & Do each 4 points; photo MOSFET relay contact output) MODEL: 22LA1–3E6–[1]

  • Code number: 22LA1–3E6-[1] Specify a code from power input options for [1] (e.g. 22LA1-3E6-K) INPUT SPECIFICATIONS Input: Dry contact, 4 points Commons: Per 4 points Sensing: 12 V DC ≥ 3 mA at ON ≤ 1 mA at OFF OUTPUT SPECIFICATIONS Output: Photo MOSFET relay, 4 points Commons: Per 2 points Contact rating: 125 V AC/DC @ 50 mA (resistive load) Max. ON resistance: 50 Ω ■ Starion No.: set an even number to one unit and a consecutive odd number to the paired unit. (e.g. "02" and PERFORMANCE Multi-transmission time: 1.5 msec. Input read time: 5 msec. per 4 points Output time OFF to ON: 8 msec. per 4 points ON to OFF: 3 msec. per 4 points I/O TERMINAL CONNECTION 12V Base Socket COM3 COM2 Do 2 Do 3 Do 4 Do 1 COM(–) Di 4 Di 3 Di 2 Di 1 V Italic fi gures indicate LED No. on the front panel.

MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 16/22 ANALOG INPUT MODULE (Ai 8 points) MODEL: 22LA1–3G3–[1]

  • Code number: 22LA1–3G3-[1] Specify a code from power input options for [1] (e.g. 22LA1-3G3-K) INPUT SPECIFICATIONS Input: 1 – 5 V DC, 8 points Operational range: 0.4 – 5.6 V DC Commons: All negatives Input resistance: 1 MΩ min. ■ Starion No.: Match the number of input and output modules PERFORMANCE in percentage of span A/D conversion: ±0.2 % Resolution: ≤ 0.025 % Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) A/D conversion cycle: 1 sec. max. per 8 points Multi-transmission time: 12 msec. TERMINAL CONNECTION (INPUT) Base Socket COM(–) Ai 6 Ai 7 Ai 8 COM(–) 11 Ai 5 COM(–) Ai 4 Ai 3 Ai 2 Ai 1

MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 17/22 ANALOG INPUT MODULE (Ai 4 points) MODEL: 22LA1–3G4–[1]

  • Code number: 22LA1–3G4-[1] Specify a code from power input options for [1] (e.g. 22LA1-3G4-K) INPUT SPECIFICATIONS Input: 1 – 5 V DC, 4 points Operational range: 0.4 – 5.6 V DC Commons: All negatives Input resistance: 1 MΩ min. ■ Starion No.: Match the number of input and output modules PERFORMANCE in percentage of span A/D conversion: ±0.2 % Resolution: ≤ 0.025 % Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) A/D conversion cycle: 0.5 sec. max. per 4 points Multi-transmission time: 6 msec. TERMINAL CONNECTION (INPUT) Base Socket Ai 1 Ai 2 Ai 3 Ai 4

MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 18/22 ANALOG OUTPUT MODULE (Ao 8 points) MODEL: 22LA1–3M3–[1]

  • Code number: 22LA1–3M3-[1] Specify a code from power input options for [1] (e.g. 22LA1-3M3-K) OUTPUT SPECIFICATIONS Output: 1 – 5 V DC, 8 points Operational range: 0.4 – 5.6 V DC Commons: All negatives Load resistance: 10 kΩ min. ■ Starion No.: Match the number of input and output modules PERFORMANCE in percentage of span D/A conversion cycle: 1 sec. max. per 8 points D/A conversion: ±0.2 % Resolution: ≤ 0.025 % Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) TERMINAL CONNECTION (OUTPUT) Base Socket COM(–) Ao 6 Ao 7 Ao 8 COM(–) 11 Ao 5 COM(–) Ao 4 Ao 3 Ao 2 Ao 1

MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 19/22 ANALOG OUTPUT MODULE (Ao 4 points) MODEL: 22LA1–3M4–[1]

  • Code number: 22LA1–3M4-[1] Specify a code from power input options for [1] (e.g. 22LA1-3M4-K) OUTPUT SPECIFICATIONS Output: 1 – 5 V DC, 4 points Operational range: 0.4 – 5.6 V DC Commons: all negatives Load resistance: 10 kΩ min. ■ Starion No.: Match the number of input and output modules PERFORMANCE in percentage of span D/A conversion cycle: 0.5 sec. max. per 4 points D/A conversion: ±0.2 % Resolution: ≤ 0.025 % Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) TERMINAL CONNECTION (OUTPUT) Base Socket Ao 1 Ao 2 Ao 3 Ao 4

MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 20/22 PULSE INPUT MODULE (Pi 4 points) MODEL: 22LA1–3P4–[1]

  • Code number: 22LA1–3P4-[1] Specify a code from power input options for [1] (e.g. 22LA1-3P4-K) INPUT SPECIFICATIONS ■ Pulse Input: Dry contact, 4 points Commons: All negatives Frequency: 0 – 10 kHz (approx.) Pulse width requirement: 20.0 msec. min. for both L and H levels Sensing: 12 V DC ≥ 3 mA at ON; ≤ 1 mA at OFF Counter: 0 – 16383 (3FFF(16)); reset to zero at overflow. ■ Reset input: Closing across the terminals 9 – 15 at power startup initializes the counter values for Pi 1 thr. 4. Close for at least 5 sec. after the power start up. Reset the input unit counter first and then that of the output unit. ■ Starion No.: Match the number of input and output modules PERFORMANCE Multi-transmission time: 6 msec. Input read time: 5 msec. per 4 points TERMINAL CONNECTION (INPUT) Base Socket COM(–) Pi 4 Pi 3 Pi 2 Pi 1 V 12V Italic figures indicate LED No. on the front panel. RESET

MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 21/22 PULSE OUTPUT MODULE (Po 4 points) MODEL: 22LA1–3U4–[1]

  • Code number: 22LA1–3U4-[1] Specify a code from power input options for [1] (e.g. 22LA1-3U4-K) INPUT SPECIFICATIONS ■ Reset input: Closing across the terminals 9 – 15 at power startup initializes the counter values for Po 1 thr. 4. Close for at least 5 sec. after the power start up. Reset the input unit counter first and then that of the output unit. OUTPUT SPECIFICATIONS Output: Photo MOSFET relay, 4 points Commons: All negatives Max. frequency: Approx. 10 kHz Pulse width: Approx. 50 % duty ratio at the maximum frequency Contact rating: 125 V AC/DC @ 50 mA (resistive load) Max. ON resistance: 50 Ω ■ Starion No.: Match the number of input and output modules PERFORMANCE Output time OFF to ON: 8 msec. per 4 points ON to OFF: 3 msec. per 4 points TERMINAL CONNECTION (OUTPUT) Base Socket COM(–) Po 4 Po 3 Po 2 Po 1 Italic figures indicate LED No. on the front panel. RESET

MODEL: 22LA1 http://www.m-system.co.jp/ 22LA1 SPECIFICATIONS ES-6554 Rev.8 Page 22/22 Specifications are subject to change without notice.