info@keller-druck.com Find your local KELLER contact keller-pressure.com Page 1 of 2 Piezoresistive OEM Pressure Transmitters -40…150 °C, with embedded signal conditioning Series 4LC…9LC The Series 4LC…9LC family of miniature OEM pressure transmitters combines a piezo resistive pressure sensor with -40…150 °C-capable signal conditioning in one compact, easy-to-integrate package. Technology The «LC» line of miniature pressure transmitters leverages KELLER’s extensive background in high-stability piezoresistive pressure sensors and innovative digital signal processing. Now, both pressure sensor and signal processor are integrated into a miniature, hermetically-sealed housing no larger than was once required for the sensor only! The name given to this new technology is Chip-In-Oil (CIO). CIO means not only that the entire pressure transmitter is embedded within a hermetically-sealed, oil-filled housing, but that this transmitter can then be seamlessly integrated into the OEM product, achieving cost savings and system performance not possible with other, conventional technologies. Interfaces The ratiometric analog output simplifies the integrators task by providing a signal output wherein the output is ratiometric to the supply, thereby eliminating the need to incorporate an expensive, absolute reference. Providing an 0,5…4,5 VDC output from a 5 VDC supply, the LC-transmitter is inherently protected against overvoltage and reverse polarity up to ±33 VDC and provides noise immunity by a factor of 10X relative to the latest standards regarding emitted and conducted EMI. Performance features
- Hermetically protected sensor electronics - extremely resistant to environmental influences
- Operating temperature up to 150 °C
- Ultra-compact, robust housing made from stainless steel (optionally Hastelloy C-276)
- No external electronics for compensation or signal processing
- Extremely accurate, outstanding long-term stability, no hysteresis
- Pressure ranges of 1 bar to 1000 bar
- Extremely easy to integrate in overall systems
- Two-chip solution with pressure sensor and signal processing separation provides a high degree of flexibility. 4LC 8LC 9FLC 7LC 9LC 6LHPC / 7LHPC (High Pressure) Connection 4LC / ø 11 4,2 5 8 8 GNDOUT Supply 9 9 571 0,5 0,5 0,5 7LC / ø 15 8LC / ø 17 9LC / ø 19 ø 5,08 9FLC / ø 17 / ø 21 6LHPC / ø 13 7LHPC / ø 15 Generally applies: No force must be applied to the pins! 3 3
info@keller-druck.com Find your local KELLER contact keller-pressure.com Page 2 of 2 (1) TEB (Total Error Band): Maximum deviation within specified pressure and compensated temperature range (2) abs: Absolute Pressure Measurement (PAA: Absolute. Zero at vacuum PA: Sealed Gauge. Zero at 1,0 bar abs.) (3) rel: Referential version (PR: Vented Gauge. Zero at atmospheric pressure) Type 3-wire Signal Output 0,1…0,9 V/V (0,5…4,5 V ratiometric) Supply 5,0 VDC ± 0,5 V Reverse Polarity and Overvoltage Protection ± 33 VDC (permanently on all leads) Power Consumption max. 8 mA Load Resistance > 5 kΩ Sampling Rate / Bandwidth 2 kHz / 800 Hz Rise Time T99 1 ms Response Time (Supply ON) < 5 ms (0…99 %) Isolation > 100 MΩ @ 500 VDC EMC-Industry EN 61000-6-2 / EN 61000-6-3 / EN 61326-2-3 / BCI 200mA @ 1…250MHz DO-160F RF Susceptibility (radiated) Cat. R: 150 V/m @ 400 MHz…8 GHz PM / 30 V/m @ 100 MHz…400 MHz CW & SW, DO-160F RF Susceptibility (conducted) Cat.R: 30 mA @ 10 kHz…40 MHz / 3 mA @ 40 MHz…400 MHz Material in Contact with Media Stainless Steel AISI 316L (DIN 1.4404 / 1.4435) / optionally Hastelloy C-276 6LHPC: Steel, 7LHPC: Steel or optionally and @ > 600 bar and > 100 °C Inconel 718 O-Rings: Viton® 70 Shore A (-20…200 °C, exchangeable), @ 6LHPC / 7LHPC: Viton® 90 Shore A Support Ring @ 6LHPC / 7LHPC: PTFE Vibration Endurance 20 g, 5....2000 Hz, X/Y/Z-axis Shock 75 g sine 11 ms Oil Filling Silicone oil, others on request Electrical Connection – Glass feed through pins D = 0,45 mm, L = 2,5…4 mm, Positioning: See scale drawing. Attention: It’s important not to load forces to the pins! – Silicone wires 0,09 mm2 @ the glass feed through pin – Plug JST 1,5 mm, 3-pole. Type: B3B-ZR-SM4-TF. Only for -20…85 °C and not for 4LC & 6LC As counterpart: IDC-socket with 1,27 mm flat band. Type: 03ZR-8M-P As counterpart: Crimp-socket with wires AWG 28. Type: ZHR-3, Crimp-contact: SZH-003-P0.5 Options Other pressure and temperature ranges, other accuracies. SigCond Sensor Specifications Accuracy* max. +/- 0,25 %FS * Linearity best straight line @ RT, hysteresis, repeatability Overpressure 2,5 x pressure range, max. 300 bar resp. 1200 bar (6LHPC, 7LHPC) Long Term Stability max. +/- 0,3 %FS Applications requiring a mechanical package with certain pressure and electrical connec - tions can be accommodated. Almost any combination of connections is possible with our Series 21C product line. CIO is optio- nally available with the 2-wire I2C digital interface, enabling bus-capability in the system design. Type/ Version Dimensions [mm] Pressure Range Operating Temperature Comp. Temp. Range TEB (1) [%FS] 4LC ø 11 x 4,2 3…200 bar abs.(2) -10…+80 °C 0…50 °C ± 1,0 %FS 7LC ø 15 x 5 2…200 bar abs. 8LC ø 17 x 7 1…200 bar abs. 1…30 bar rel. -40…+150 °C 9LC ø 19 x 5 -40…+125 °C -40…+150 °C (only > 3 bar) ± 1,5 %FS ± 2,5 %FS9FLC ø 17 x 5,5 Flange ø 21 1…50 bar abs. 1…30 bar rel. 6LHPC ø 13 x 8 200…1000 bar -40…+150 °C 7LHPC ø 15 x 8 -40…+150 °C ± 2,0 %FS Serie 21C The integration of the transmitter elec- tronics means that even extremely small designs can be properly sup- ported, and there is a conside rable amount of freedom for connection variants. Furthermore, there is no need to protect the nonexistent downstream electronics against moisture and con- densation. +VCC +OUT +GND Glass Feed Through Housing Oil Filling O-RingDiaphragm Laser Welding