Features

Applications

  • Explosion-proof device
  • Stainless steel, hermetic seal construction
  • Rated to 10 amps
  • Rated for 28 VDC and 110 VAC, 60-900 Hz
  • Available in single pole, double throw (SPDT) and double pole, double throw (DPDT)
  • Screw or soldier terminals
  • Door interlock for guarding
  • Aircraft engine compartments
  • Access and maintenance hatches
  • Electrical cabinets
  • Machinery
  • Industrial Equipment SPECIFICATIONS Current Capacity 28 VDC 115 VAC, 60 - 900Hz Resistance 5 amps Inductive 3 amps Lamp 2 amps Dielectric Strength 1250 volts (RMS) Full Overtavel Force 5 lbs max Life @ Rated Load 25,000 cycles Amb. Temperature Range -65F to +275F (-65C to +150C) Seal Hermetic per MIL-S-8805D Max Leak Rate 1x10-8 C.C. std. HE/sec Backfill Dry nitrogen Max MV Drop 20 MV @ 1 amp Vibration Resistance Swept sinusoidal vibration per MIL-STD-202-204 (Test Condition A) Shock Resistance 100 G’s, 1/2 sine, 11 ms duration Page 1 www.sensata.comCopyright © 2019 Sensata Technologies, Inc.

Dimensions inches (mm) Note: All dimensions are reference only. DIMENSIONS SINGLE POLE, PUSH-PULL INTERLOCK SWITCH (21462, 21689) DOUBLE POLE, PUSH-PULL INTERLOCK SWITCH (21628,21693-1) Page 2 www.sensata.comCopyright © 2019 Sensata Technologies, Inc.

www.sensata.com CONTACT US Copyright © 2019 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Revised 08/16/19 Americas +1 (508)-236-3287 klixon@sensata.com Ask for AEROSPACE WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE

  • The product’s side panels may be hot, allow the product to cool before touching
  • Follow proper mounting instructions including torque values
  • Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
  • Disconnect all power before installing or working with this equipment
  • Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury.