Part Number: 2107A Fieldbus, 24 Pr #18 Str TC, XLPO Ins, IS/OS, TPE Jkt, CMG Product Description Fieldbus, 24 Pair 18AWG (7x26) Tinned Copper, XLPO Insulation, Individual & Overall Beldfoil® Shield, Orange TPE Outer Jacket, CMG Technical Specifications Physical Characteristics (Overall) Conductor AWG Stranding Material No. of Pairs 18 7x26 TC - Tinned Copper 24 Conductor Count: 48 Total Number of Pairs: 24 Insulation Material Nominal Wall Thickness XLP - Cross Linked Polyolefin 0.032 in Color Chart Number Color

1 Blue and Orange Numbered 1

2 Blue and Orange Numbered 2

3 Blue and Orange Numbered 3

4 Blue and Orange Numbered 4

5 Blue and Orange Numbered 5

6 Blue and Orange Numbered 6

7 Blue and Orange Numbered 7

8 Blue and Orange Numbered 8

9 Blue and Orange Numbered 9

10 Blue and Orange Numbered 10

11 Blue and Orange Numbered 11

12 Blue and Orange Numbered 12

13 Blue and Orange Numbered 13

14 Blue and Orange Numbered 14

15 Blue and Orange Numbered 15

16 Blue and Orange Numbered 16

17 Blue and Orange Numbered 17

18 Blue and Orange Numbered 18

19 Blue and Orange Numbered 19

20 Blue and Orange Numbered 20

21 Blue and Orange Numbered 21

22 Blue and Orange Numbered 22

23 Blue and Orange Numbered 23

24 Blue and Orange Numbered 24

Type Material Material Trade Name Coverage [%] Drainwire Material Drainwire AWG

Tape Aluminum Foil-Polyester Tape Beldfoil® 100 % TC - Tinned Copper 20 Outer Shield Material Type Material Material Trade Name Coverage [%] Drainwire Material Drainwire AWG Tape Aluminum/Polyester Beldfoil® 100 % TC - Tinned Copper 18 Outer Jacket Material Material Nominal Diameter Nominal Wall Thickness TPE - Thermoplastic Elastomer 1.389 in 0.085 in

Electrical Characteristics

5.86 Ohm/1000ft

Nom. Capacitance Conductor to Conductor 22 pF/ft Inductance Nominal Inductance 0.22 µH/ft Impedance Nominal Characteristic Impedance

100 Ohm

High Frequency (Nominal/Typical) Frequency [MHz] Nom. Insertion Loss 0.039 MHz 0.08 dB/100ft Delay Nominal Velocity of Propagation (VP) [%] 64 % Current Max. Recommended Current [A]

5.4 Amps per conductor

300 V RMS

Electrical Characteristics Notes: Max Propagation Delay Change From 7.812 kHz to 39.06 kHz: 518 pS/ft Other Electrical Characteristic 2: 31.25 KBits/sec Temperature Range UL Temp Rating: 90°C Operating Temp Range: -40°C To 90°C Mechanical Characteristics Oil Resistance: Yes Bulk Cable Weight: 797 lbs/1000ft Max Recommended Pulling Tension: 1400 lbs Min Bend Radius/Minor Axis: 14.0 in Standards NEC Articles: 800 NEC/(UL) Specification: CMG, ITC, PLTC-ER CEC/C(UL) Specification: CIC, TC CSA AWM Specification: AWM I A/B II A/B

Applicable Environmental and Other Programs EU Directive 2000/53/EC (ELV): Yes EU Directive 2003/11/EC (BFR): Yes EU Directive 2011/65/EU (ROHS II): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive 2015/863/EU: Yes EU Directive Compliance: EU Directive 2003/11/EC (BFR) EU CE Mark: Yes CA Prop 65 (CJ for Wire & Cable): Yes Suitability Suitability - Burial: Yes Suitability - Indoor: Yes Suitability - Outdoor: Yes Suitability - Sunlight Resistance: Yes Flammability, LS0H, Toxicity Testing UL Flammability: UL1685 UL Loading CSA Flammability: FT4 ISO/IEC Flammability: 60332-3-24 (Category C) UL voltage rating: 300 V RMS Plenum/Non-Plenum Plenum (Y/N): No Part Number Variants Item # Color UPC 2107A 0061000 Blue, Light 612825129103 2107A 0031000 Orange 612825129097 History Update and Revision: Revision Number: 0.200 Revision Date: 08-28-2019 © 2019 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.