2105A BELDEN | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

Part Number: 2105A Fieldbus, 16 Pr #18 Str TC, XLPO Ins, IS/OS, TPE Jkt, CMG Product Description Fieldbus, 16 Pair 18AWG (7x26) Tinned Copper, XLPO Insulation, Individual & Overall Beldfoil® Shield, Orange TPE Outer Jacket, CMG Technical Specifications Physical Characteristics (Overall) Conductor AWG Stranding Material No. of Pairs 18 7x26 TC - Tinned Copper 16 Conductor Count: 32 Insulation Material Nominal Wall Thickness XLP - Cross Linked Polyolefin 0.032 in Color Chart Number Color

1 Blue and Orange Numbered 1

2 Blue and Orange Numbered 2

3 Blue and Orange Numbered 3

4 Blue and Orange Numbered 4

5 Blue and Orange Numbered 5

6 Blue and Orange Numbered 6

7 Blue and Orange Numbered 7

8 Blue and Orange Numbered 8

9 Blue and Orange Numbered 9

10 Blue and Orange Numbered 10

11 Blue and Orange Numbered 11

12 Blue and Orange Numbered 12

13 Blue and Orange Numbered 13

14 Blue and Orange Numbered 14

15 Blue and Orange Numbered 15

16 Blue and Orange Numbered 16

Type Material Material Trade Name Coverage [%] Drainwire Material Drainwire AWG Drainwire Construction n x D Tape Aluminum Foil-Polyester Tape Beldfoil® 100 % TC - Tinned Copper 20 7x28 Outer Shield Material Type Material Material Trade Name Coverage [%] Drainwire Material Drainwire AWG Drainwire Construction n x D Tape Aluminum/Polyester Beldfoil® 100 % TC - Tinned Copper 18 7x26 mm Outer Jacket Material Material Nominal Diameter Nominal Wall Thickness Ripcord TPE - Thermoplastic Elastomer 1.126 in 0.085 in Yes

Electrical Characteristics

5.86 Ohm/1000ft

Max. Capacitance Unbalance Nom. Capacitance Conductor to Conductor 1.2 pF/ft 22 pF/ft Inductance Nominal Inductance 0.22 µH/ft Impedance Nominal Characteristic Impedance

120 Ohm

High Frequency (Nominal/Typical) Frequency [MHz] Nom. Insertion Loss 0.039 MHz 0.08 dB/100ft Delay Nominal Velocity of Propagation (VP) [%] 64 % High Freq Max. Insertion Loss (Attenuation) Max./Min. Input Impedance (unFitted) 0.091 dB/100ft 100 Ohm Current Element Max. Recommended Current [A] Per Conductor 5.4 Amps per Conductor Voltage Description UL Voltage Rating CSA CIC type TC 300 V RMS Electrical Characteristics Notes: Max Propagation Delay Change From 7.812 kHz to 39.06 kHz: 518 pS/ft Other Electrical Characteristic 2: 31.25 KBits/sec Temperature Range Installation Temp Rating: -25°C UL Temp Rating: 90°C Operating Temp Range: -40°C To 90°C Mechanical Characteristics Oil Resistance: Yes Bulk Cable Weight: 608 lbs/1000ft Max Recommended Pulling Tension: 940 lbs Min Bend Radius/Minor Axis: 11.5 in Standards NEC Articles: 800 NEC/(UL) Specification: CMG, ITC, PLTC-ER CEC/C(UL) Specification: CIC, TC CSA AWM Specification: AWM I A/B II A/B Applicable Environmental and Other Programs EU Directive 2000/53/EC (ELV): Yes EU Directive 2003/11/EC (BFR): Yes EU Directive 2011/65/EU (ROHS II): Yes

EU Directive 2012/19/EU (WEEE): Yes EU Directive 2015/863/EU: Yes EU Directive Compliance: EU Directive 2003/11/EC (BFR) EU CE Mark: Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Suitability Suitability - Burial: Yes Suitability - Indoor: Yes Suitability - Oil Resistance: Yes Suitability - Outdoor: Yes Suitability - Sunlight Resistance: Yes Flammability, LS0H, Toxicity Testing UL Flammability: UL1685 UL Loading CSA Flammability: FT4 ISO/IEC Flammability: 60332-3-24 (Category C) UL voltage rating: 300 V RMS Plenum/Non-Plenum Plenum (Y/N): No Part Number Variants Item # Color UPC Length 2105A 0061000 Blue, Light 612825129011 1,000 ft 2105A 0065000 Blue, Light 612825129028 5,000 ft 2105A 0031000 Orange 612825128991 1,000 ft 2105A 0035000 Orange 612825129004 5,000 ft History Update and Revision: Revision Number: 0.346 Revision Date: 08-22-2019 © 2019 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.