Ampère Part numbers 400 V 50 a. 60 Hz 3pole 4pole 5pole 9h 6h 6h 500 V 50 a. 60 Hz 3pole 4pole 5pole 7h 7h 7h > 50 - 500 V 100 - 300 Hz 3pole 4pole 5pole 10h 10h 10h > 50 - 500 V over 300 - 500 Hz 3pole 4pole 5pole 2h 2h 2h

2 P + E

3 P + E 3 P + N + E

50 a. 60 Hz 3pole 4pole pole 4h 4h 4h 230 V 50 a. 60 Hz 3pole 4pole 5pole 6h 9h 9h

14 Availability of blue printed (or not listed)

frequencies and voltages up to 690 V on request! Other voltages and frequencies on request. Part numbers in bold letters are standard versions. 16 4 210 406 DF 10 144 16 5 210 DF 10 173 32 4 230 406 DF 10 198 32 5 230 DF 10 241 63 4 260 406 DF 10 603 63 5 260 DF 5 685 for voltage ranges of 110 V - 690 V Phase sequence control plugs IP 44 Phase inverters IP 44, with flexible cable entry 16 5 210 PH 10 180 16 5 210 PHNI (with nickel plated contacts + glass-fibre reinforced enclosure) 10 183 32 5 230 PH 10 257 32 5 230 PHNI (with nickel plated contacts + glass-fibre reinforced enclosure) 10 264 16 5 211 PH 10 174 16 5 211 PHNI (with nickel plated contacts + glass-fibre reinforced enclosure) 10 180 32 5 231 PH 10 245 32 5 231 PHNI (with nickel plated contacts + glass-fibre reinforced enclosure) 10 257 Phase inverters IP 44, with gland entry Plugs IP 44 and IP 67 IEC/EN 60 309 Plugs IP 67, with gland entry 16 5 219 NI 10 199 32 5 239 NI 10 286 63 5 269 NI 5 771 125 5 279 NI 2 1473 63 3 269 304 269 306 269 309 5 501 63 4 269 404 269 409 269 406 269 407 269 410 269 402 5 623 63 5 269 504 269 509 269 5 668 125 3 279 304 279 306 279 309 2 1185 125 4 279 404 279 409 279 406 279 407 279 410 279 402 2 1329 125 5 279 504 279 509 279 2 1473 plugs IP 44, angled, back part RAL 7035 light grey 16 3 216 304 216 306 216 309 10 106 16 4 216 404 216 409 216 406 216 407 216 410 216 402 10 150 16 5 216 504 216 509 216 10/60 163 32 3 236 304 236 306 236 309 10 214 32 4 236 404 236 409 236 406 236 407 236 410 236 402 10 230 32 5 236 504 236 509 236 10 251 230DF 230 PH 231 PH 269 236 Plugs IP 67, with screw terminals or as screwless SL version with insulation displacement technique 16 3 219 304 219 306 219 309 (with gland entry and screw terminals) 10 133 16 4 219 404 219 409 219 406 219 407 219 410 219 402 10 212 16 5 219 504 219 509 219 10 236 32 3 239 304 239 306 239 309 10 290 32 4 239 404 239 409 239 406 239 407 239 410 239 402 10 300 32 5 239 504 239 509 239 10 340 219306 239 gland entry cable ► gland new design All red marked plugs come with new design and cable gland. Additionally these are also available as screwless version with IDC insulation displacement connection. To order a plug as screwless version, just add „SL“ to the part number, e.g. 219SL. (with nickel plated contacts and glass-fibre reinforced enclosure)

Amp. 16 32 Poles 3 4 5 3 4 5 d 85 98 98 115 115 115 e 50.3 64.3 64.3 72 72 72 f 70 86 86 96 96 100 n 37 37 37 45.8 45.8 45.8 p 8/15 10/16.5 10/16.5 11/22 11/22 11/22 Page 14, item 6 219 NI, 239 NI, 269, 279 etc. Page 14, item 5b 219, 239 etc. (red part nos.) n Øp Øu Øe m d Amp. 16 32 Poles 5 5 d 153 181 Øe 65 72 f 75 88 m 117 138 n 37 46 Øp 8/21 11/24 Amp. 16 Poles 3 d 126 m 110 n 37 u 72 Øp 7.5-14.5 Amp. 16 32 63 Poles 4 5 4 5 4 5 d 65 65 155 72 240 81 Øe 58 65 72 72 81 81 f 68 75 79 88 97 97 n 37 37 46 46 67 67 Amp. 16 32 Poles 5 5 d 131 155 Øe 65 73 f 75 88 m 112 133 n 37 46 Øp 7.5 - 14.5 10 - 19.5 Amp. 16 16 32 32 Poles 4 5 3 / 4 5 d 150-161 150-161 174-183 174-183 Ø e Ø 65 Ø 65 Ø 72 Ø 72 m 111 111 127 127 n 36.5 36.5 45.5 45.5 Ø u Ø 81 Ø 89 Ø 95 Ø 100 Amp. 16 32 Poles 3 4 5 3 4 5 b 45.5 60 60 60 60 60 d 74 80 80 97 97 97 e 60 74 74 82 82 82 f 60 73 73 80 80 86 l 28 31 31 45 45 45 n 110 117 117 141 141 141 M 20 20 20 25 25 25 Page 15, item 1 610, 630 etc. Amp. 16 32 Poles 4 5 3 4 5 c 5 5 5 5 5 d 96 96 96 96 96 e 95 95 95 95 95 f 140 140 140 140 140 n 151 151 160 160 160 v 7 7 7 7 7 M 20/25 20/25 20/25 20/25 20/25 Page 15, item 2 616, 636 etc. Amp. 16 32 63 Poles 3 4 5 3 4 5 3 4 5 a 30 40 40 45 45 45 90 90 90 b 55 68 68 78 78 78 90 90 90 d 52 66 66 75 75 75 114 114 114 e 65 80 80 90 90 90 114 114 114 f 72 90 92 103 103 103 116 116 116 h 38 52 52 60 60 60 70 70 70 n 97 110 110 129 129 129 185 185 185 y 30 38 38 44 44 44 56 56 56 z 36 46 46 54 54 54 65 65 65 Page 15, item 3 611, 631, 661 etc. M M 210 306, 260 etc. and NI versions 216, 236 etc.

210 PH, 230 PH & NI versions

211 PH, 231 PH & NI versions

230 DF etc. Amp. 16 32 63 Poles 3 5 5 3 4 5 d 143 153 181 252 252 252 Øe 51 65 72 81 81 81 f 60 75 88 97 97 97 m 108 117 138 192 192 192 n 37 37 46 67 67 67 Øp 7/13 8/21 11/24 15/33 15/33 15/33 219 306 etc. (black part nos.) Page 15, item 4 615, 635 etc. Amp. 16 32 Poles 3 4 5 3 4 5 a 47 60 60 60 60 60 b 47 60 60 60 60 60 d 62 80 80 80 80 80 e 62 80 80 80 80 80 f 47 47 47 56 56 56 h 50 67 67 71 71 71 n 22 22 22 22 22 22 Einbauöffnung fixing hole Einbauöffnung fixing hole Amp. 16 32 63 125 Poles 5 5 3 4 5 3 4 5 d 139 166 243 243 243 315 315 315 m 114 135 195 195 195 258 258 258 n 37 46 67 67 67 75.5 75.5 75.5 u 88 103 110 110 110 130 130 130 Øp 10-19.5 18-24.5 18-35 18-35 18-35 24-45 24-45 24-45 n Øp Øu Øe m d