20ETF IRF | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 8
Technical content
Bulletin I2111 rev. C 03/99 QUIETIR Series 20ETF..S VF < 1.2V @ 10A IFSM = 300A VRRM 200 to 600V Major Ratings and Characteristics Characteristics 20ETF..S Units IF(AV) Sinusoidal waveform 20 A VRRM range 200 to 600 V IFSM 300 A V F @ 10 A, TJ = 25°C 1.2 V trr @ 1A, 100A/µs 60 ns T J range - 40 to 150 °C D 2 Pak (SMD-220) Description/Features The 20ETF..S soft recovery rectifier QUIETIR series has been optimized for combined short reverse recovery time and low forward voltage drop. The glass passivation ensures stable reliable operation in the most severe temperature and power cycling conditions. Typical applications are both: output rectification and freewheeling in inverters, choppers and converters and input rectifications where severe restrictions on conducted EMI should be met. Package Outline
20ETF..S QUIETIR Series Bulletin I2111 rev. C 03/99 www.irf.com IF(AV) Max. Average Forward Current 20 A @ T C = 97° C, 180° conduction half sine wave IFSM Max. Peak One Cycle Non-Repetitive 250 10ms Sine pulse, rated V RRM applied Surge Current 300 10ms Sine pulse, no voltage reapplied I2t Max. I 2t for fusing 316 10ms Sine pulse, rated V RRM applied 442 10ms Sine pulse, no voltage reapplied I2√t Max. I2√t for fusing 4420 A 2√s t = 0.1 to 10ms, no voltage reapplied Part Number VRRM , maximum V RSM , maximum non repetitive IRRM peak reverse voltage peak reverse voltage 150°C VV m A 20ETF02S 200 300 20ETF04S 400 500 5 20ETF06S 600 700 Voltage Ratings Absolute Maximum Ratings Electrical Specifications Recovery Characteristics Parameters 20ETF..S Units Conditions A A2s VFM Max. Forward Voltage Drop 1.30 V @ 20A, TJ = 25°C
1.67 V @ 60A, TJ = 25°C
rt Forward slope resistance 12.5 m Ω VF(TO) Threshold voltage 0.9 V IRM Max. Reverse Leakage Current 0.1 T J = 25 °C
5.0 T J = 150 °C
Parameters 20ETF..S Units Conditions TJ = 150°C VR = rated VRRM mA trr Reverse Recovery Time 160 ns I F @ 20Apk Irr Reverse Recovery Current 10 A @ 100A/ µs Q rr Reverse Recovery Charge 1.25 µC @ 25°C S Snap Factor tb/ta 0.6 typical Parameters 20ETF..S Units Conditions ta tb trr t Ifm dir dt Qrr Irm (REC) mA
20ETF..S QUIETIR Series Bulletin I2111 rev. C 03/99 www.irf.com TJ Max. Junction Temperature Range - 40 to 150 °C Tstg Max. Storage Temperature Range - 40 to 150 °C R thJC Max. Thermal Resistance Junction 0.9 °C/W DC operation to Case R thJA Max. Thermal Resistance Junction 40 °C/W to Ambient (PCB Mount) Ts Soldering Temperature 240 °C wt Approximate Weight 2 (0.07) g (oz.) Case Style D 2Pak Thermal-Mechanical Specifications Parameters 20ETF.. Units Conditions Fig. 1 - Current Rating Characteristics Fig. 2 - Current Rating Characteristics Fig. 3 - Forward Power Loss Characteristics Fig. 4 - Forward Power Loss Characteristics When mounted on 1" square (650mm2) PCB of FR-4 or G-10 material 4 oz (140µm) copper 40°C/W For recommended footprint and soldering techniques refer to application note #AN-994 100 110 120 130 140 150 02468 1 0 1 2 1 4 1 6 1 8 2 0 2 2 30° 60° 90° 120° 180° Maximum Allowable Case Temperature (°C) Conduction Angle Average Forward Current (A) 20ETF.. Series R (DC) = 0.9 K/WthJC 100 110 120 130 140 150 0 5 10 15 20 25 30 35 DC 30° 60° 90° 120° 180° Maximum Allowable Case Temperature (°C) Conduction Period Average Forward Current (A) 20ETF.. Series R (DC) = 0.9 K/WthJC 0 5 10 15 20 25 RMS Limit 180° 120° 90° 60° 30° Conduction Angle Average Forward Current (A) Maximum Average Forward Power Loss (W) 20ETF.. Series T = 150°C J 0 5 10 15 20 25 30 35 DC 180° 120° 90° 60° 30° RMS Limit Conduction Period Average Forward Current (A) Maximum Average Forward Power Loss (W) 20ETF.. Series T = 150°C J
20ETF..S QUIETIR Series Bulletin I2111 rev. C 03/99 www.irf.com Fig. 8 - Recovery Time Characteristics, TJ = 25°C Fig. 9 - Recovery Time Characteristics, TJ = 150°C Fig. 7 - Forward Voltage Drop Characteristics Fig. 5 - Maximum Non-Repetitive Surge Current Fig. 6 - Maximum Non-Repetitive Surge Current 100 150 200 250 300 11 0 1 0 0 Number Of Equal Amplitude Half Cycle Current Pulses (N)Peak Half Sine Wave Forward Current (A) Initial T = 150°C @ 60 Hz 0.0083 s @ 50 Hz 0.0100 s J 20ETF.. Series At Any Rated Load Condition And With Rated V Applied Following Surge.RRM 100 150 200 250 300 350 400 450 500 550 0.001 0.01 0.1 1 Pulse Train Duration (s) Peak Half Sine Wave Forward Current (A) Versus Pulse Train Duration. 20ETF.. Series Maximum Non Repetitive Surge Current Initial T = 150°C No Voltage Reapplied Rated V ReappliedRRM J 100 1000 012345 T = 25°CJ Instantaneous Forward Voltage (V) Instantaneous Forward Current (A) T = 150°CJ 20ETF.. Series 0.05 0.1 0.15 0.2 0 200 400 600 800 1000 Rate Of Fall Of Forward Current - di/dt (A/µs) 1 A 5 A 10 A I = 30 A 20 A Maximum Reverse Recovery Time - Trr (µs) 20ETF.. Series T = 25 °CJ FM 0.1 0.2 0.3 0.4 0.5 0 200 400 600 800 1000 Rate Of Fall Of Forward Current - di/dt (A/µs) 1 A 5 A 10 A I = 30 A 20 A Maximum Reverse Recovery Time - Trr (µs) 20ETF.. Series T = 150 °CJ FM
20ETF..S QUIETIR Series Bulletin I2111 rev. C 03/99 www.irf.com Fig. 14 - Thermal Impedance ZthJC Characteristics Fig. 12 - Recovery Current Characteristics, TJ = 25°C Fig. 13 - Recovery Current Characteristics, TJ = 150°C Fig. 10 - Recovery Charge Characteristics, TJ = 25°C Fig. 11 - Recovery Charge Characteristics, TJ = 150°C 0.5 1.5 2.5 3.5 0 200 400 600 800 1000 Rate Of Fall Of Forward Current - di/dt (A/µs) 1 A 5 A 10 A I = 30 A 20 A Maximum Reverse Recovery Charge - Qrr (µC) 20ETF.. Series T = 25 °CJ FM 0 200 400 600 800 1000 Rate Of Fall Of Forward Current - di/dt (A/µs) 1 A 5 A 10 A I = 30 A 20 A Maximum Reverse Recovery Charge - Qrr (µC) 20ETF.. Series T = 150 °CJ FM 0 200 400 600 800 1000 Maximum Reverse Recovery Current - Irr (A) Rate Of Fall Of Forward Current - di/dt (A/µs) 1 A 5 A 10 A I = 30 A 20 A 20ETF.. Series T = 25 °CJ FM 100 0 200 400 600 800 1000 Maximum Reverse Recovery Current - Irr (A) Rate Of Fall Of Forward Current - di/dt (A/µs) 1 A 5 A 10 A I = 30 A 20 A 20ETF.. Series T = 150 °CJ FM 0.01 0.1 0.0001 0.001 0.01 0.1 1 Square Wave Pulse Duration (s) thJC Steady State Value (DC Operation) Transient T hermal Impedance Z ( K/W) 20ETF.. Series Single Pulse D = 0.50 D = 0.33 D = 0.25 D = 0.17 D = 0.08
20ETF..S QUIETIR Series Bulletin I2111 rev. C 03/99 www.irf.com BASE (A) (A) (K) Outline T able 10.16 (0.40) REF. 8.89 (0.35) 4.57 (0.18) 4.32 (0.17) 0.61 (0.02) MAX. 5.08 (0.20) REF. 1.32 (0.05) 1.22 (0.05) 6.47 (0.25) 6.18 (0.24)93° RE F . 2.61 (0.10) 2.32 (0.09) 5.28 (0.21) 4.78 (0.19) 4.69 (0.18) 4.20 (0.16) 0.55 (0.02) 0.46 (0.02) 14.73 (0.58) 15.49 (0.61) 1.40 (0.055) 1.14 (0.045)3X 0.93 (0.37) 0.69 (0.27)2X 11.43 (0.45) 17.78 (0.70) 8.89 (0.35) 3.81 (0.15) 2.08 (0.08) 2X 2.54 (0.10) MINIMUM RECOMMENDED FOOTPRINT Dimensions in millimeters and inches Ordering Information T able
20 E T F 06 S TRL
2 - Circuit Configuration: E = Single Diode 3 - T = TO-220AC 4 - F = Fast Recovery 5 - Voltage code: Code x 100 = VRRM 6 -S = D2Pak (SMD-220) Version 7 - Tape and Reel Option: TRL = Left Reel TRR = Right Orientation Reel 02 = 200V 04 = 400V 06 = 600V
20ETF..S QUIETIR Series Bulletin I2111 rev. C 03/99 www.irf.com 9G3A 20ETF06S 9512 EXAMPLE: THIS IS AN 20ETF06S INTERNATIONAL RECTIFIER LOGO PART NUMBER Marking Information DATE CODE (YYWW) YY = YEAR WW = WEEK ASSEMBLY LOT CODE Dimensions in millimeters and inches (K) (A)(A) TRR FEED DIRECTIO N TRL FEED DIRECTIO N 10.90 (0.429) 15.90 (0.626) 1.75 (0.069) 1.25 (0.049) 1.85 (0.073) 1.65 (0.065) 4.10 (0.161) 3.90 (0.153) 1.60 (0.063) 1.50 (0.059) DIA. 1.60 (0.063) 1.50 (0.059) DIA. 11.60 (0.457) 11.40 (0.449) 15.42 (0.609) 15.22 (0.601) 4.72 (0.186) 4.52 (0.178) 24.30 (0.957) 23.90 (0.941) 0.368 (0.0145) 0.342 (0.0135) 360 (14.173) DIA. MAX. 26.40 (1.039) 24.40 (0.961) 13.50 (0.532) 12.80 (0.504)DIA. 60 (2.362) DIA. MIN. SMD-220 Tape & Reel When ordering, indicate the part number, part orientation, and the quantity. Quantities are in multiples of 800 pieces per reel for both TRL and TRR. T ape & Reel Information
20ETF..S QUIETIR Series Bulletin I2111 rev. C 03/99 www.irf.com EUROPEAN HEADQUARTERS: Hurst Green, Oxted, Surrey RH8 9BB, U.K. Tel: ++ 44 1883 732020. Fax: ++ 44 1883 733408. IR CANADA: 15 Lincoln Court, Brampton, Markham, Ontario L6T3Z2. Tel: (905) 453 2200. Fax: (905) 475 8801. IR GERMANY: Saalburgstrasse 157, 61350 Bad Homburg. Tel: ++ 49 6172 96590. Fax: ++ 49 6172 965933. IR ITALY:Via Liguria 49, 10071 Borgaro, Torino. Tel: ++ 39 11 4510111. Fax: ++ 39 11 4510220. IR FAR EAST:K&H Bldg., 2F, 30-4 Nishi-Ikebukuro 3-Chome, Toshima-Ku, Tokyo, Japan 171. Tel: 81 3 3983 0086. IR SOUTHEAST ASIA: 1 Kim Seng Promenade, Great World City West Tower,13-11, Singapore 237994. Tel: ++ 65 838 4630. http://www.irf.com Fax-On-Demand: +44 1883 733420 Data and specifications subject to change without notice.