5SP SENSATA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 6

Technical content

www.sensata.com The Sensata SP Refrigeration Package is a compact motor starter and motor protector package. The SP serves as a combination control which: 1. Uses industry leading 4TM motor protector 2. Performs the PTC solid state starter function 3. Replaces the compressor terminal cover 4. Available for both RSIR and RSCR applications 5. 5SP eliminates the need of wiring harness for a run capacitor The SP unit plugs directly onto the compressor terminal pins. This provides installed cost savings opportunities through the elimination of the terminal cover and a reduction in assembly labor as well as the elimination of the run capacitor wiring harness in the 5SP model. | 5SP SERIES Refrigeration Package Product Overview Key Features Quality and Performance

  • Applicable to fractional horsepower compressors used in refrigerators, freezers, water coolers, dehumidifiers, vending machines, and similar refrigeration applications.
  • Utilizes ceramic PTC (Positive Temperature Coefficient) pill materials to energize/de-energize motor start windings.
  • Readily available for 120 and 220 volt applications.
  • Available with 1/8”, 1/4” and 3/16” termination.
  • Allows direct mounting of the run capacitor in the 5SP model.
  • Provides significant installed cost savings opportunities by requiring fewer components to attach to the compressor, particularly the 5SP which features a run capacitor mount for easy assembly.
  • Eliminates run capacitor wiring harness in 5SP models.
  • Eliminates terminal cover. PTC Reliability
  • High reliability solid state motor starter.
  • Life cycle: minimum 500,000 cycles at maximum rated current/voltage conditions.
  • 100% electrically tested twice.
  • Dissipates less than 2.5 watts under normal operating conditions 4TM Reliability
  • Life cycle: designed to achieve a minimum of 10,000 electrical cycles.
  • Minimum 15 day locked rotor testing. Convenience
  • Fits most existing compressor terminal fences – Eliminates retooling
  • Elimination of 4TM reapplication in most cases – Easy product conversion
  • 5SP allows for flexibility in run capacitor size and shape – Can accommodate various capacitors
  • 5SP one piece connector design allows for simultaneous disconnect
  • Optional 3/16” continual anti-miswire features or 1/8” one piece simultaneous disconnect termination Copyright © 2024 Sensata Technologies, Inc.

www.sensata.com Page 2 Copyright © 2024 Sensata Technologies, Inc. SPECIFICATIONS Assembly Process Description Electrical Component Assembly The illustration (A) depicts the assembly of the 5SP onto the compressor. The female flag connectors are plugged onto the SP terminals. The SP package is simply plugged onto the compressor terminals. The 5SP with the one piece simultaneous disconnect (B) replaces the separate female flag connectors. SP Models

www.sensata.com Page 3 Copyright © 2024 Sensata Technologies, Inc. Curves Electrical Schematics PTC Performance Common Electrical Rating When power is first applied to the compressor via the SP, the PTC pill is in the low resistance state. Current flows through the PTC pill to the start windings, causing a beneficial phase angle shift between start and main windings, and resulting in an increase in the starting torque. The current flow through the PTC pill causes self-heating and it switches to the high resistance state, resulting in low power dissipation while the compressor is running. SP Series Application Voltage VmaxImax Nominal Resistance (Ohms) Heat Capacity MCP 14CX 15CX 16CX 17CX 18CX 19CX 20CX 22CX 24CX 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.40 For other ratings contact Sensata. APPLICATION PROCEDURE Step 1: Assemble Data Required for New Applications Example R0 Resistance 5.0 Ohms Max. Volt (Vmax) 162 VAC Max Current (In Rush)

8 Amp

0.5 Sec @ 8 Amp Ambient 25oC Example Motor Type RSCR Reset Time < 80 Sec @ Nom. Volt Ambient 25°C Test Requirements
  • 250K Cycles @ Max. Operational Conditions
  • 300 Hrs. @ Max. Volt +10% 120 120 120 240 240 240 240 120 240 4.7±20% 6.8±20% 10±20% 22±20% 33±20% 15±20% 47±20% 3.9±20% 68±20%

www.sensata.com Page 4 Copyright © 2024 Sensata Technologies, Inc. Step 2: Select PTC pill based on resistance and maximum operating conditions. Step 4: Switch Time Calculation Equation Time MCP (TS-TA) I2R MCP Heat Capacity (Watt-Sec/°C) TS Switch Temperature (°C) TA Ambient Temperature (°C) I Inrush Current (Amps-Rms) R Initial Device Resistance Under Voltage (Use R0 x 0.8) Example R 5.0 Ohms (R=5x.8=4) I 8 Amps TS 120°C TA 25°C MCP 1.60 Time (Sec) 1.60 (95) (82) (4) Switch Time 0.59 Sec. (See electrical rating on previous page). (See terminal configurations on previous page). The amount of time required for PTC to switch into its high resistance state can be approximated as follows: Theoretical Calculated PTC Switch Time Should Be Time Required to Start Motor Glossary Measured resistance value at 2 5 oC Max. voltage of 2.0 volts. Cooldown Time Time required for the PTC resistance to return to two times the initial value (2R0) Curie Point (Switch Temp.) Temperature obtained with a resistance value of two times (2R0) the minimum resistance value (R0) VMAX Maximum operating voltage which may be applied across the PTC continuously at the ambient steady high resistance state. VR Application rated supplied voltage/ 120 or 240 VAC (below Vmax) ISS Steady state current remaining at maximum operating voltage. IMAX Maximum operating current.

www.sensata.com Page 5 Application Notes 1. The surface and terminals of the SP device and its components can reach high temperatures under normal running conditions. Any material in contact with the SP device and its terminals, including wire and quick-connect receptacle plastic insulation, should have a minimum temperature rating (RTI) of 105oC. Adequate spacing should be provided to insulate lower-rated materials from this heat source. 2. The SP device and its components should be protected from potential sources of liquid, such as the evaporator tray and water connections. 3. Certain materials, such as chlorine (Cl) containing gases, can degrade the characteristics of the SP device and its components. The SP device and its components should not be exposed to Sulphur (S) or chlorine (Cl) containing gases, and must be kept away from materials that can generate them. In particular, avoid the use of polyvinyl chloride (PVC) insulation in contact with the SP device and its terminals. Important Notice: Sensata Technologies reserves the right to make changes to, or to discontinue, any product or service identified in this publication without notice. Before placing orders, users should obtain the latest version of the relevant information to verify that the information being relied upon is current. S Sensata Technologies assumes no responsibility for customers’ product designs or applications. Users must determine the suitability of the Sensata device described in this publication for their application, including the level of reliability required. Many factors beyond Sensata’s control can affect the use and performance of a Sensata product in a particular application, including the conditions under which the product is used and the time and environmental conditions in which the product is expected to perform. As these factors are uniquely within the user’s knowledge and control, it is essential that the user evaluate the Sensata product to determine whether it is fit for a particular purpose and suitable for the user’s application. Sensata Technologies products are sold subject to Sensata’s Terms and Conditions of Sale which can be found at www.sensata.com/terms.htm Copyright © 2024 Sensata Technologies, Inc.

SP COMBO CODING SYSTEM Example : 5SP14A419NFD02 Basic Designation Designating 8EA PTC Pill Series Disc Temperature Plus Additional Characteristics Designating Heater Code PTC Pill Supplier 5SP. Numeral of the Form 0X or xx One alphanumeric character. Two numerals. Three numerals. One alphanumeric character designating any additional electrical physical characteristics. 5SP 14 A NFD419 O2 UL / CUL File SA3745 IEC / ENEC File 2014531.01 AGENCY APPROVALS & CERTIFICATIONS Copyright © 2024 Sensata Technologies, Inc. Rev. 07/30/24 www.sensata.com Datasheets provided by Sensata Technologies, Inc., its subsidiaries and/or affiliates (“Sensata”) are solely intended to assist third parties (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation, and judgment in designing Buyer’s systems and products. Sensata datasheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular datasheet. Sensata may make corrections, enhancements, improvements, and other changes to its datasheets or components without notice. Buyers are authorized to use Sensata datasheets with the Sensata component(s) identified in each particular datasheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATASHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATASHEETS OR USE OF THE DATASHEETS, EXPRESS, IMPLIED, OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATASHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY , AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Page 6 CONTACT US Americas +1 (508) 236-2551 electrical-protection-sales@sensata. com Europe, Middle East & Africa +1 (760) 597 7042 @sensata.com EP_Asia_Public@list.sensata.com China +86 (21)2306 1651 Japan +81 (45)277 7104 Korea +82 (53) 644 9685 India +91 (40)4033 9611 Rest of Asia +