CIBIMETAL ASHCROFT | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 5
Technical content
All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Everyangle™, Duratemp®, Maxivision®, Trust the Shield® are trademarks and Gold ServiceSM is a service mark of Ashcroft Inc..For more information, see Ashcroft Brands & Trademarks ©2024 Ashcroft Inc. CI_bimetal_ds_RevF_01-25-24 ashcroft.com | 1.800.328.8258 | Contact Us
FEATURES
Hermetically sealed case to prevent entry of moisture, interior corrosion and coil freeze up Maxivision® dial for precise readings (minimize parallax reading errors) Silicone dampened coil for reduction of pointer flutter on high vibration applications and provides improved response times Customized dial printing TYPICAL USES General industrial HVAC Equipment skids Pharmaceutical / Biotech Food and beverages SPECIFICATIONS Accuracy: ±1% of span ASME B40.200 (B40.3 Grade A) Stem Length: 2½˝ to 24˝ Dial Sizes: 2˝, 3˝, 5˝ Dial Style: Maxivision®, black figures on white background Overtemperature Limits: Top of Range °F up to 250 251-550 551-1,000 Max. Over Temperature 100% of span 50% of span 800 °F(1) (1) Satisfactory for continuous service up to 800 °F (425 °C). Can be used for intermittent service from 800 °F to 1,000 °F (425 °C to 500 °C). Use Ashcroft Duratemp® thermometers for ranges above and below those listed above. Process Connection: Plain, Pointed Stem, 1⁄4 NPT, 1⁄2 NPT Stem diameter: 0.250˝, 0.375˝ Case & Stem: 304 Stainless steel, Hermetically sealed Process Connection Location: 2˝: Rear 3˝, 5˝: lower, rear Pointer: Black Window: Glass, Acrylic, Safety Glass Approvals: RoHS KEY BENEFITS
- Tamper resistant case
- NEMA 4X/IP66 protection
- 5-year limited warranty
- All welded stainless steel construction CI Bimetal 2˝, 3˝, 5˝ dial sizes MIN/MAX TEMPERATURE LIMITS Version Ambient Dry -40 °F to 200 °F (-40 °C to 93 °C) of 5 CI Bimetal Thermometer CAUTION Thermowells should be used on all pressurized applications over 15 psi, to protect the thermometer from corrosion or physical damage, and to facilitate removal of the thermometer without disturbing the process.
All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Everyangle™, Duratemp®, Maxivision®, Trust the Shield® are trademarks and Gold ServiceSM is a service mark of Ashcroft Inc..For more information, see Ashcroft Brands & Trademarks ©2024 Ashcroft Inc. CI_bimetal_ds_RevF_01-25-24 ashcroft.com | 1.800.328.8258 | Contact Us ORDERING CODE Example: 30CI 60 R 060 XSG 0/200F Dial Size and Model 20CI - 2˝ Tamper resistant bimetal 30CI - 3˝ Tamper resistant bimetal 30CI 50CI - 5˝ Tamper resistant bimetal Stem and Connection 40 - Plain - no connection 50 - Pointed stem - no connection (2˝ case only) 60 - 1⁄2 Fixed NPT for 3˝ & 5˝ but 1⁄4 fixed NPT for 2˝ 60 Connection Location R - Rear connection R L - Lower connection (Not available on 2˝ case) Stem Length (Consult factory for custom or longer stem length) 025 - 21⁄2˝ 040 - 4˝ 060 - 6˝ 060 090 - 9˝ 120 - 12˝ 150 - 15˝ 180 - 18˝ 240 - 24˝ Options - (if choosing an option(s) must include an “X’’) X_ _ CS - Dual scale DM - Dial marking NH - Stainless steel tag PD - Plastic window SG - Shatterproof glass SG C4 - Traceable calibration certificate S1 - Silicone free 3B - 3⁄8˝ stem diameter with 1⁄2 NPT 02 - 1⁄4 NPT (only available on rear connection) Temperature Ranges (see table on page 3) 0/200 °F 0/200 °F of 5 CI Bimetal Thermometer
All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Everyangle™, Duratemp®, Maxivision®, Trust the Shield® are trademarks and Gold ServiceSM is a service mark of Ashcroft Inc..For more information, see Ashcroft Brands & Trademarks ©2024 Ashcroft Inc. CI_bimetal_ds_RevF_01-25-24 ashcroft.com | 1.800.328.8258 | Contact Us Fahrenheit Inner Range Inner ºF Outer ºC Restrictions -100/100 -70/40 -80/120 -60/50 -50/200 -40/93 -50/250 -40/120 -40/120 -40/50 -40/160 -40/70 -20/120 -30/50 0/100 -20/40 4˝ minimum for lower 0/150 -20/65 4˝ minimum for lower 0/160 -20/70 4˝ minimum for lower 0/200 -20/93 0/250 -20/120 0/300 -20/150 0/350 -20/170 0/400 -20/200 0/500 -20/260 20/120 -5/50 30/130 0/55 30/240 0/115 50/300 10/150 50/400 10/200 50/550 10/290 0/700 -20/370 4˝ minimum 100/800 50/430 4˝ minimum 150/750 65/395 4˝ minimum 200/700 100/370 4˝ minimum 200/1000 100/550 4˝ minimum Satisfactory continuous service from 800 ºF or 426 ºC Intermittent service from 800 ºF to 1000 º F or 425 ºC to 500 ºC Celsius Inner Range Inner ºC Outer ºF Restrictions -50/50 -50/120 -50/180 -50/350 -40/100 -40/210 -40/160 -40/320 -30/70 -20/160 -20/180 0/350 -20/120 0/250 -10/50 20/120 -10/110 20/230 0/60 30/140 4˝ minimum 0/100 30/210 0/120 30/250 0/150 30/300 0/200 30/400 0/250 30/480 0/300 30/570 10/150 50/300 0/400 30/750 4˝ minimum 0/500 30/390 4˝ minimum 50/450 120/840 4˝ minimum Satisfactory continuous service from 800 ºF or 426 ºC Intermittent service from 800 ºF to 1000 ºF or 425 ºC to 500 ºC 100/500 220/930 4˝ minimum Satisfactory continuous service from 800 ºF or 426 ºC Intermittent service from 800 ºF to 1000 ºF or 425 ºC to 500 ºC MAXIVISION DIAL ASSEMBLED IN USA BY ASHCROFT 100 150 200 250 -20 40 60 100 120 MAXIVISION DIAL ASSEMBLED IN USA BY ASHCROFT -20 40 60 100 120 100 150 200 250 MAXIVISION DIAL ASSEMBLED IN USA BY ASHCROFT 100 150 200 250 -20 40 60 100 120 MAXIVISION DIAL ASSEMBLED IN USA BY ASHCROFT -20 40 60 100 120 100 150 200 250 of 5 CI Bimetal Thermometer
All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Everyangle™, Duratemp®, Maxivision®, Trust the Shield® are trademarks and Gold ServiceSM is a service mark of Ashcroft Inc..For more information, see Ashcroft Brands & Trademarks ©2024 Ashcroft Inc. CI_bimetal_ds_RevF_01-25-24 ashcroft.com | 1.800.328.8258 | Contact Us Single Scale Ranges Restrictions ºF ºC Restrictions -100/100 -80/120 -50/200 -50/50 -50/250 -50/180 Can be Liquid filled -40/120 -40/100 -40/160 -40/160 -20/120 -30/70 4˝ minimum for lowers only 0/100 -20/180 0/150 -10/50 0/160 — 4” minimum for lower 0/200 -10/110 0/250 0/50 0/300 0/60 4˝ minimum 0/400 — 0/500 0/100 4˝ minimum for lowers only 20/120 0/120 4˝ minimum for lowers only 30/130 0/150 30/240 0/200 50/300 0/250 50/400 0/300 50/550 10/150 4˝ minimum 0/700 0/400 4˝ minimum 4˝ minimum 100/800 0/500 4˝ minimum 4˝ minimum 150/750 50/450 4˝ minimum Satisfactory continuous service from 800 ºF or 426 ºC. Intermittent service from 800 ºF to 1,000 ºF or 425 ºC to 500 ºC 4˝ minimum 200/700 100/500 4˝ minimum Satisfactory continuous service from 800 ºF or 426 ºC. Intermittent service from 800 ºF to 1,000 ºF or 425 ºC to 500 ºC 4˝ minimum Satisfactory continuous service from 800 ºF or 426 ºC. Intermittent service from 800 ºF to 1,000 ºF or 425 ºC to 500 ºC of 5 CI Bimetal Thermometer
All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Everyangle™, Duratemp®, Maxivision®, Trust the Shield® are trademarks and Gold ServiceSM is a service mark of Ashcroft Inc..For more information, see Ashcroft Brands & Trademarks ©2024 Ashcroft Inc. CI_bimetal_ds_RevF_01-25-24 ashcroft.com | 1.800.328.8258 | Contact Us Dial Size (Inches) Process Connection Locations A B C D E S NPT Hex. Weight (oz)(1) S - 21⁄2˝
2 Rear (Plain) 23⁄32
[53] 3⁄8 [10] 3⁄8 [10] (2) 11⁄16 41⁄2
2 Rear
(Plain, pointed stem) 23⁄32 [53] 3⁄8 [10] 3⁄8 [10] (2) 11⁄16 41⁄2 (Threaded) 23⁄32 [53] 3⁄8 [10] 3⁄8 [10] (2) 1⁄4 11⁄16 41⁄2
3 Rear 35⁄32
[80] 19⁄32 [15] 3⁄8 [10] (2) 1⁄2 7⁄8 7
3 Lower 35⁄32
[80] 127⁄32 [47] 25⁄8 [67] 1⁄4 [6] (2) 1⁄2 7⁄8 11
5 Rear 51⁄32
[128] 23⁄32 [18] 3⁄8 [10] (2) 1⁄2 7⁄8 16
5 Lower 51⁄32
[128] 115⁄16 [49] 35⁄8 [92] 1⁄4 [6] (2) 1⁄2 7⁄8 26 S A C B A B D E S NOTES: 1. Add 1 oz. for every 2˝ inches of stem length 2. "S" dimensions are 21⁄2, 4, 6, 9, 12, 15, 18 and 24˝ (STD.). Stem diameter is 1⁄4˝ (STD.) 3. Stem tolerance is ± 0.250˝ DIMENSIONS in [ ] are millimeters For reference only, consult Ashcroft for specific dimensional drawings of 5 CI Bimetal Thermometer