DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 1

Technical content

DIMENSIONS:

0 PLC

1 PLC

2 PLC

3 PLC

4 PLC

C B A C B A 4 3 2 1 OFSCALE SHEET REV NAME SIZE CAGE CODE DRAWING NO TOLERANCES UNLESS OTHERWISE SPECIFIED: DWN CHK APVD MATERIAL FINISH REVISIONS P LTR DATE APVDDWNDESCRIPTION ALL RIGHTS RESERVED. RELEASED FOR PUBLICATION C COPYRIGHT THIS DRAWING IS UNPUBLISHED. PRODUCT SPEC APPLICATION SPEC WEIGHT 1470-19 (3/13) RESTRICTED TO THIS DRAWING IS A CONTROLLED DOCUMENT. TE Connectivity CUSTOMER DRAWING 2061926 R. COOLEN 08APR2015 M. SCHOLTEN 08APR2015 S. BORGAS 08APR2015 4:5 1 1 A -- - mm 0,5 0,25 0,03 0,005 0,0010 FullFLEX MINI FIELD INSTALL KIT BY - - - A RELEASE 02NOV2016 KZ RS 29,2 (n )21,2 ( )102 "L"

3 FullFLEX MINI FIELD INSTALL NUT FOR CABLE GLAND 1

2 FullFLEX MINI FIELD INSTALL CABLE GLAND SEAL 1

1 FullFLEX MINI FIELD INSTALL CORRUGATED TUBE with COUPLING 1

TE Part Number "L" (mm) Cable Diameter 2061926-1 500 ±20 4.8±0.2 mm 2061926-2 300 ±20 4.8±0.2 mm ASSEMBLED 2061926-X NOTES: 1. THIS FIELD INSTALL KIT SHOULD BE USED WITH RUGGEDIZED CABLE AND RUGGED FAN-OUT CONSTRUCTION NO 900 MICRON TERMINATIONS TO BE USED. 2. CABLE DIAMETER RANGE: SEE TABLE 3. THE FLAMMABILITY RATING OF THE MATERIAL IS UL94-V0 4. THE MATERIAL IS HALOGEN FREE ACCORDING IEC 60754-2 5. EACH ASSEMBLY IS PACKED IN A PROTECTIVE SLEEVE - GLAND SEAL AND NUT ARE SEPARATELY SEALED 6. AN INSTRUCTION SHEET IS PACKED WITH EACH FIELD INSTALL KIT 2 3 SCALE 1:2