Features
n Size: 11.8 mm diameter, 12 mm length n 60 kA surge rating n High power handling n Low leakage n RoHS compliant* n UL Recognized
Applications
n Telecommunications equipment n Industrial equipment/electronics Characteristics
2061 Series High-Current 2-Electrode Gas Discharge Tube
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011. Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their specific applications. Test Methods per ITU-T K.12 and IEC 61643-311. Characteristic Model No. 2061-23 2061-25 2061-30 2061-35 2061-42 DC Sparkover ±20 % @ 100 V/s 230 V 250 V 300 V 350 V 420 V Impulse Sparkover (1)
100 V/µs
1000 V/µs
< 600 V < 700 V < 600 V < 700 V < 700 V < 800 V < 800 V < 900 V < 900 V < 1000 V Notes:
- The 2061 Series is NOT intended for use as a surface mount component.
- UL Recognized component, UL File E313168.
- At delivery AQL 0.65, level II DIN ISO 2859 (2) DC Sparkover Voltage IR Measuring Voltage 230–400 V 100 V 420–800 V 250 V (3) Network Applied DC Sparkover Voltage DC Holdover Voltage 230–250 V 135 V 300–800 V 150 V *RoHS COMPLIANT LEAD FREE *RoHS COMPLIANTVERSIONS AVAILABLE LEAD FREE VERSIONS ARE RoHS COMPLIANT* Characteristic Model No. 2061-47 2061-60 2061-70 2061-80 DC Sparkover ±20 % @ 100 V/s 470 V 600 V 700 V 800 V Impulse Sparkover (1)
< 900 V < 1100 V < 1100 V < 1300 V < 1200 V < 1400 V < 1300 V < 1500 V (1) Impulse Sparkover voltage is defined as typical values of distribution.
Specifications are subject to change without notice. The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time. Users should verify actual device performance in their specific applications. Model 2061 ships standard bulk, 60 pcs. per tray.; 180 pcs. per box. Product Dimensions How to Order 2061 - xx - A __ LF Model Number Designator Voltage (Divided by 10) 23 = 230 V 47 = 470 V 25 = 250 V 60 = 600 V 30 = 300 V 70 = 700 V 35 = 350 V 80 = 800 V 42 = 420 V Leads A = No Leads Packaging (Blank) = Bulk Packaging - 60 pcs./tray (Standard) RoHS Compliancy LF = RoHS Compliant Product REV. F 07/16 DIMENSIONS: MM (INCHES) 12.0 ± 0.3 (.472 ± .012) 11.8 ± 0.2 (.465 ± .008)