LTW-593DS MICROSEMI | Alldatasheet

Document overview

  • Manufacturer or author: pwissel
  • PDF pages: 3

Technical content

AIRCRAFT AC POWER BUS PROTECTION WWW.Microsemi .COM S C O T T S D A L E D I V I S I O N 200KP295CVCL and 200KP295CA 200KP295CVCL and 200KP295CA

DESCRIPTION

Microsemi’s 200 kW bidirectional Transient Voltage Suppressor (TVS) protects 120 volt ac airborne electronic equipment from harsh lightning environments per RTCA/DO-160D Section 22 and is compatible with Section 16 for 180 volt ac 100 ms highline surges. Microsemi also offers a broad spectrum of other TVS products to meet your needs. IMPORTANT: For the most current data, consult MICROSEMI’s website: http://www.microsemi.com

FEATURES

Symmetrical bidirectional TVS construction Available as either low clamp with “CVCL” suffix or normal clamping features with “CA” suffix. Suppresses transients up to 200 kW @ 10/40 us Fast response with less than 5 ns turn-on time. Optional 100% screening for avionics grade is available by adding MA prefix to part number for added 100% temperature cycle -55oC to +125oC (10X), surge (3X) in each direction, 24 hours HTRB in each direction, and post test (VZ and IR) Options for screening in accordance with MIL- PRF-19500 for JAN JANTX, JANTXV, and JANS are also available by adding MQ, MX, MV, or MSP prefixes respectively to part numbers Moisture classification is Level 1 with no dry pack required per IPC/JEDEC J-STD-020B Pin injection protection per RTCA/DO-160D up to Level 4 for Waveform 4 (6.4/69 µs) and Level 3 for Waveform 5A (40/120 μs) Compatible with “abnormal surge and variation from a controlled steady-state level” as described in 16.5.3.3 of RTCA/DO-160D. The 200KP295CVCL is designed for low clamping protection of 400V transistors, MOSFETs and IGBTs in off-line switching power supplies. The 200KP295CA normal clamp device is for use in less sensitive applications including RFI/EMI filters and general across-the-line protection. Secondary lightning protection per IEC61000-4-5 with

12 Ohms source impedance for Class 1,2, 3 and 4

Secondary lightning protection per IEC61000-4-5 with

2 Ohms source impedance for Class 2 and 3

MECHANICAL & PACKAGING Steady-state power dissipation: 7 W @ TA = 25oC Peak Pulse Power at 25oC: 200 kW at 10/40 µs (linear derate to zero @ 150oC) Repetition rate: 0.01% max. Operating & storage temperatures: -55oC to +150oC Temperature coefficient of voltage: +0.100%/oC max Solder Temperatures: 260oC for 10 s maximum CASE: Inner Shell – Epoxy Encapsulated. Exterior Shell – Diallyl Phthallate, glass filled Meets UL 94V-0 flammability requirements FINISH: Tin-Lead plated readily solderable per MIL-STD-750, method 2026 Polarity: No band required for bidirectional MARKING: Manufacturers logo and part number Add prefix MA, MQ, MX, etc., for screened parts Package dimensions: See last page ELECTRICAL PARAMETERS @ 25oC Devices are Bi-directional Working Standoff Voltage VWM Maximum Standby Current ID @ VWM Minimum Breakdown Voltage VBR @ I(BR) Breakdown Current I(BR) Maximum Clamping Voltage VC @ IPP Peak Pulse Current IPP @ 10/40 μs MICROSEMI PART NUMBER V max μA Volts mA Volts Amps 200KP295CVCL 295 300 410 300 200KP295CA 295 300 460 300 Microsemi Scottsdale Division Page 1 Copyright © 2004 8-08-2004 REV B 8700 E. Thomas Rd. PO Box 1390, Scottsdale, AZ 85252 USA, (480) 941-6300, Fax: (480) 947-1503