HFE80V-60 KG | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 4
Technical content
HFE80V-60_EN Rev 1.0 1 A HFE80V-60 HIGH VOLTAGE DC RELAY
- 60A, 200Vdc - 1 Form A Relay
- 3kVac dielectric strength between coil and contacts
- Different control coil voltages: 12, 24Vdc
- Outline Dimensions: (42.6x55.1x45.5) mm
- Dimensions with flanges: (76.6x55.1x45.5) mm
- Quick Connect terminals
- Mounting flanges reinforced with compression sleeves
- RoHS compliant materials and processes Contact Data Characteristics Rated Load 60A @ 200VDC Insulation resistance 1,000MΩ (at 500 Vdc) Contact form 1 Form A Dielectric strength: Contact material Cu Alloy Coil to contact 3kVac for 1 min. Contact resistance* ≤1.5mΩ (at 20A) † Across open contacts 2kVac for 1 min. Max. switching voltage 250Vdc Dielectric creepage Max. switching current 100A Ambient temperature -40°C to +85°C Set time ≤ 30ms Ambient humidity 5% - 85% RH Reset time ≤ 10ms Vibration 1.5 mm (DA) 10 Hz to 500 Hz ‡ Bounce time ≤ 5ms Shock resistance: Electrical endurance 10,000 cycles § Functional 196 m/s 2 ** Mechanical endurance 200,000 cycles Destructive 490 m/s 2 †† Coil power consumption 3W Termination: Coil termination Quick Connect terminals Load termination Quick Connect terminals Unit Weight Approximately 175g * Typical value for Initial Contact Resistance: Using a sample quantity of at least 20 units, take the average value from 5 continuous measurements from each sample † Rating at 23°C ‡ Acceleration of 49ms2, 8 hours each for both directions on of three mutually perpendicular axes,4 hours each for the energized and non-energized status, total 24 hours. There shall not be any abnormalities on relay appearance, construction and performance § Rating at: 150Vdc / 60A ** Duration 11ms, 500 ops for each direction of three mutually perpendicular axes, 250 ops each for the energized and non- energized status, total 3000 shocks †† Duration 6ms, 50 shocks for each direction of three mutually perpendicular axes, total 300 shocks
HFE80V-60_EN Rev 1.0 2 A Current Endurance‡‡ Current Duration 60A Continuous 90A 12 min 180A 15 s 600A 1 s ‡‡ Testing Conditions: 1V, 85°C, 15 mm2 cable used Electrical Endurance§§ Contact Rating Contact Rating Operations Switching: Steady 60A Contact Voltage: 12Vdc 0.6s/5.4s 100,000 ops Switching: Steady 60A Contact Voltage: 48Vdc 50,000 ops Switching: Steady 60A Contact Voltage: 72Vdc 30,000 ops Switching: Steady 60A Contact Voltage: 150Vdc 10,000 ops Switching: Steady 10A Contact Voltage: 150Vdc 75,000 ops Switching: Steady 60A Contact Voltage: 200Vdc 5,000 ops §§23oC room temperature Coil Resistance (Ω±10%) at 23°C Nominal Coil Voltage Pick-up Voltage Drop-out Voltage Coil Resi stance 12Vdc ≤9Vdc ≥1Vdc 48Ω 24Vdc ≤18Vdc ≥2Vdc 192Ω
Ordering Information
HFE80 V - 60/ ■ -■ -H T 2 XXX Type Application V : Vehicle Series Code 60: 60A Load Voltage 150 : 150Vdc 200 : 200Vdc Coil Voltage 12 : 12Vdc 24 : 24Vdc Contact Type H : 1 Form A Contact Material T : AgSnO 2 Coil Termination 2 : Quick Connect Terminals Special Code XXX : Customer Customization
HFE80V-60_EN Rev 1.0 3 A D i m e n s i o n a l D r a w i n g s (Unit: mm) W i r i n g D i a g r a m s Single Coil 1. Coil is polarity independent 2. Load connections are polarity independent
HFE80V-60_EN Rev 1.0 4 A Application Notes 1. To maintain the relay in its closed state, the coil voltage should reach the stated pick-up voltage. 2. For definitions of terms used in this data sheet, see glossary at www.kgtechnologies.net. Disclaimer: This data sheet is for reference only. All specifications are s ubject to change without prior notice. KG Technologies, Inc. cannot predict every possible application for our relays. While we do our best to make our relays as versatile as possible, we highly recommend contacting our en gineering team if you have any questions. KG Technologies, Inc. is not responsible for malfunctioning relays when operated outside the specified parameters given in this data sheet.