The EtherNet/IP to Serial Linking Device allows you to connect any serial device to your ControlLogix™ and CompactLogix™ PLC from Rockwell Automation. The stand-alone Linking Device is less expensive than an in-chassis-based solution, and has even better integration to Studio 5000® from Rockwell Automation. EtherNet/IP™ to Serial Linking Device In short: EtherNet/IP Adapter Class product which is tightly integrated to Rockwell Studio5000 allowing you to connect serial devices to Rockwell PLCs. Connect devices that use: RS232/422/485 interfaces Modbus RTU Rockwell DF1 Catalog number: HMS-EN2SE-R The EtherNet/IP to Serial Linking Device will:
- Minimize costs when connecting serial devices to your PLC. More cost- efficient than an in-chassi solution.
- Allow you to easily retrofit existing serial devices.
- Speed up configuration — Automated process inside Rockwell Studio5000. Technical highlights
- Custom Add-On Profile: simplifies configuration and reduces commissioning time, dynamically generates data structures. No need for any ladder logic or Add On Instructions.
- No hardware of software changes for the connected device.
- Does not affect backplane performance (PLC execution time), even when large amount of data is transferred to the Logix PLC.
- EtherNet/IP Adapter Class product supporting announced-based DLR.
- Supports serial RS232/422/485, Modbus RTU and DF1.
- Automatically generates named and structured Studio 5000 controller tags based on the configuration — no need for add-on instructions or creating alias tags.
- Connects up to 31 serial nodes.
- ODVA, CE, UL, ATEX and Haz.Loc. certifications pending. HMS provides a full 3 year product guarantee The EtherNet/IP to Serial Linking Device from HMS integrates industrial devices communicating via RS232/422/485, Modbus RTU and DF1 with a Rockwell PLC. You do all configuration in your familar Rockwell Studio 5000 environment. All network and device configuration is done within Studio 5000. See how it works at www.encompass.hms- networks.com Integrated into Studio5000
Anybus® is a registered trademark of HMS Industrial Networks AB, Sweden, USA, Germany and other countries. Other marks and words belong to their respective companies. All other product or service names mentioned in this document are trademarks of their respective companies. Part No: MMA433 Version 2 03/2019 - © HMS Industrial Networks - All rights reserved - HMS reserves the right to make modifications without prior notice. TECHNICAL SPECIFICATIONS Power connector 2-pole Phoenix plug DIN rail connector with PE Status LEDs Network connectors Configuration switches (behind lid) EtherNet/IP io Serial Linking Device Protocol RS232/422/485, Modbus RTU and DF1 Max stations 31 (with RS485/422) Baud rate 1,2-57,6 kbit/s Physical standards One RS232/422/485 connector and two RJ45 connectors I/O Data Max. 500 input bytes, 496 output bytes. Modbus Commands 0x01 Read Coils, 0x02 Read Discrete Inputs, 0x03 Read Holding Registers, 0x04 Read Input Registers, 0x05 Write Single Coil, 0x06 Write Single Register, 0x07 Read Exception Status, 0x08 Diagnostics, 0x0B Get Comm Event Ctr, 0x0C Get Comm Event Log, 0x0F Write Multiple Coils, 0x10 Write Multiple Registers, 0x11 Report Slave ID, 0x14 Read File Record, 0x15 Write File Record, 0x16 Mask Write Register, 0x17 Read/Write Multiple Registers, 0x18 Read FIFO Queue Customized commands can be created (in the Configuration Manager) Technical Details Standard Weight 150 g, 0,33 lb Dimensions (L•W•H) 120•75•27 mm, 4,72•2,95•1,06” Protection class IP20, NEMA rating 1 Enclosure material PC ABS, UL 94 Installation position Any Mounting DIN rail (35•7,5/15) EN 50022 Certifications UL File number: E203225 UL 508 ind. Cont. Eq. Hazardous Locations Class 1, Division 2, Groups A, B, C and D, T4 ISA 12.12.01 CE 2014/30/EU EN 61000-6-4 EN 61000-6-2
Electrical Characteristics
Power 24 VDC +/- 10 % Current consumption Max 300 mA, Typical 100 mA Hardware Characteristics Reverse voltage protection Yes Short circuit protection Yes Galvanic isolation on subnetwork Yes EN 60950-1 MTTF >550 000 h Telcordia Issue 2, Method
1 Case 3 at 30 oC
Environmental Characteristics Operating temp 0 to 55 oC, 32 to 131 oF Storage temp -40 to 85 oC, -40 to 185 oF Relative Humidity 0-95 % non condensing Installation altitude Up to 2 000 m Immunity and emission for industrial environment Electrostatic discharge +/- 4 kV EN 61000-4-2 Electro magnetic RF fields 10 V/m 80 MHz - 1 GHz
3 V/m 1,4 GHz - 2,0 GHz
1 V/m 2,0 GHz - 2,7 GHz
Fast Transients +/- 1 kV EN 61000-4-4 Surge protection +/- 1 kV EN 61000-4-5 RF conducted interference 10 V/rms EN 61000-4-6 Emission (at 10 m) 40 dB 30 MHz - 230 MHz 47 dB 30 MHz - 1 GHz CISPR 16-2-3 Single Pack Accessories Installation sheet • Dsub with screw terminals for subnetwork The configuration is integrated into Rockwell Studio5000. With a click of the mouse, you start the configurator for the Linking Device. By using the Process Tags Editor, you can save yourself a lot of work by letting the software automatically create process tags. HMS Industrial Networks – Worldwide HMS - Sweden (HQ) Tel : +46 35 17 29 00 (Halmstad HQ) E-mail: sales@hms-networks.com HMS - China Tel : +86 010 8532 3183 E-mail: cn-sales@hms-networks.com HMS - France Tel: +33 368 368 034 (Mulhouse office) E-mail: fr-sales@hms-networks.com HMS - Finland Tel: +358 404 557 381 E-mail: sales@hms-networks.com HMS - Germany Tel: +49 721 989777-000 E-mail: ge-sales@hms-networks.com HMS - India Tel: +91 83800 66578 E-mail: in-sales@hms-networks.com HMS - Italy Tel: +39 039 59662 27 E-mail: it-sales@hms-networks.com HMS - Japan Tel: +81 45 478 5340 E-mail: jp-sales@hms-networks.com HMS - Switzerland Tel: +41 61 511342-0 E-mail: sales@hms-networks.ch HMS - UK Tel: +44 1926 405599 E-mail: uk-sales@hms-networks.com HMS - United States Tel: +1 312 829 0601 E-mail: us-sales@hms-networks.com