1900 Series Precision LCR Meter

20 Measurement Parameters

The 1900 series can measure and display any two of its 15 impedance parameters simultaneously with a basic accuracy of 0.1%. Additionally, these meters can measure the DC resistance, or display the current through or voltage across a test device ensuring the operator of the real test conditions. Wide Frequency Range The 1900 series off ers over 27,000 user- programmable test frequencies to fully characterize devices over the range of 20 Hz to 1 MHz. The 1900 series consists of high- performance LCR Meters designed to perform fast, automated imped- ance measurements on a variety of electronic components and ma- terials. These meters have a basic accuracy specifi cation of 0.1% for accurate test results over a wide frequency range, from 20 Hz to 1 MHz. Besides their 15 impedance parameters, the 1900 meters are also capable of measuring dc resis- tance as well as monitoring the volt- age or current in the device under test. The units incorporate a distinc- tive sequence test mode, allowing up to 6 uniquely diff erent tests to be performed quickly on a single start command. Additionally, these me- ters include IEEE-488, RS-232, and handler interfaces, all standard. Features:

  • 20 measurement parameters
  • Frequency range: 20 Hz to 1 MHz
  • Basic measurement accuracy: 0.1%
  • Measurement speeds up to 40/sec
  • Displays voltage and current measurements
  • Wide measurement range with 5-digit measurement resolution
  • Four-terminal kelvin connections to maintain measurement integrity
  • Programmable dc bias voltage, 0-2V
  • Constant voltage (voltage leveling)
  • Automatic test sequencing: up to 6 individual tests in one pass
  • Menu-driven interface for user-friendly operation
  • Autoranging measurements or manual hold
  • Averaging measurements: up to 1000
  • Interfaces: IEEE-488.2, RS-232, and Handler
  • Open/Short zeroing and cable- compensation
  • 14 Pass/Fail bins
  • Load correction Automated Test Sequencing For increased productivity and throughput, up to six diff erent tests in sequence can be performed with a single push of the start button. Each test can have diff erent measurement parameters, test conditions, and limits. Programmable Source Impedance Measurement results can vary substantially based solely on the source impedance of the test instrument being used. To compare measurements made on other test instruments, the 1900 series can have its source impedance set at 5, 25, 50 or 100 Ω.

1910 Model

The 1910 Inductance Analyzer adds bias current capability from 1mA to 1A. The addition of bias current makes the 1910 ideal for measuring inductance of power inductors under actual operating conditions.

1920 Model

The 1920 Precision LCR Meter adds bias voltage capability from 1mV to 2V. The bias voltage feature is used for testing capacitors or providing reverse bias for testing junction capacitance of diodes and similar components.

1900 Rear Connectors

IET LABS, INC. in the Gen Rad Tradition www.ietlabs.com TEL: (516) 334-5959 • EMAIL: info@ietlabs.com

1900 Series Page 2 of 3

Measurement Speed: Speed Accuracy Setting 40 meas/sec Low, No Display 25 meas/sec Low 10 meas/sec Medium 1 meas/sec High The speed is slower at lower frequency settings and may be affected by test conditions DC measurements take 2x as long as AC measurements Ranging: Automatic, Range Hold or user-selectable Test Frequency: Range: 20 Hz to 1 MHz Resolution from 20 Hz to 1 kHz: 1 Hz Resolution from >1 kHz: 4 digits Accuracy: ±(0.02% + 0.02 Hz) Trigger: Internal (automatic) External (via RS-232, IEEE-488.2, or Handler) Manual Source Impedance: 5 Ω, 25 Ω, 50 Ω, or 100 Ω AC Test Signal: 20 mV to 1.0 V (open circuit) in 5 mV steps DC Test Signal: 20 mV to 1.0 V (open circuit) in 5 mV steps, 5 Ω source impedance DC Bias Current: (1910 only) Internal: 0 to 1 Amp in 1 mA steps DC Bias Voltage: (1920 only) Internal: 0 to 2.0 V in 1 mV steps Power: 100 to 240 Vac 50 - 60 Hz

100 W max

Formats for Results: Engineering or scientifi c format Deviation from nominal of primary parameter %Deviation from nominal of primary parameter Pass/Fail No display mode for maximum throughput Sequencing: Displays up to 6 sequential test results, primary and/or secondary Display: LCD Display with backlight Pass/Fail and Status indicators Standard Interfaces: IEEE-488, RS-232, Handler I/O Measurement Delay: Programmable from 0 to 1000 ms in 1 ms steps Averaging: 1 to 1000, programmable Median Value: Averaged over the last three measurements Setup Storage:

30 Single Tests

10 Sequential (6 tests in each)

Self-Test: Verifi es critical instrument operation at power-up or when selected from a menu Other Features: Constant-voltage mode Cable compensation (1 m, 2 m, no cable) Open/Short zeroing Distortion check Test Terminals: Four bnc connection terminals are located on the front panel Optional test fi xture available Mechanical: Dimensions: 43.2 W x 13.3 H x 40.6 D cm Weight: 8 kg (17.6 lbs) Environmental Conditions: Operating temperature: 0 to 50°C, <75% RH Storage temperature: -40 to 71°C Altitude: < 2000 m Measure Parameters: Parameter Measurement Range Basic Accuracy Low Medium High DCR 0.1 m W to 100 kW ±0.5% ±0.25% ±0.2% DUT AV Voltage 20 mV to 1.0 V ±(2% + 5 mV) @1kHz DUT AC Current 1 µA to 150 mA ±(2% + 5 µA) @1kHz DUT DC Voltage 20 mV to 1.0 V ±(2% + 5 mV) DUT DC Current 1 µA to 150 mA ±(2% + 5 µA) For more detailed accuracy information, see instruction manual

IET LABS, INC. in the Gen Rad Tradition www.ietlabs.com TEL: (516) 334-5959 • EMAIL: info@ietlabs.com

1900 Series Page 3 of 3

ORDERING INFORMATION

Remote Test Fixture 1689-9600 OPTIONAL ACCESSORIES: SMD Test Fixture 7000-07 Kelvin Test Leads 1700-03 Chip Component Tweezers 7000-05 Alligator Clip Leads 7000-04 bnc-bnc Extender Cable, 1 m 1689-9602 bnc-bnc Extender Cable, 2 m 1689-9602-2 Calibration Kit 950038 Also available: Rack Mount Kit 2000-16 RS232-to-USB Adapter 630250

1910 Model Standard Set:

Calibration Certifi cate traceable to SI

1920 Model Standard Set:

Calibration Certifi cate traceable to SI