190 MACOM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Features
- Standard DIP configuration mates with 16-pin socket.
- Meets FCC Part 68 (10/160µs).
- For applications in telecommunications, office automation, security devices, measurement and control equipment.
- Immersion cleanable, plastic sealed case.
- Standard, high and ultra-sensitive coils.
- Ultrasonic cleaning not recommended. Mechanical Data Termination: DIP compatible, printed circuit terminals. Enclosure Type: Immersion cleanable plastic case. Weight: 0.21 oz. (6g) approximately. Coil Data @ 23°C Operate Data @ 23°C Operate Voltage: 75% of nominal voltage. Release Voltage: 5% of nominal voltage. Operate Time: 7 ms, max. (3.5 ms, mean). Release Time: 3 ms, max. (0.8 ms, mean). Bounce Time: Operate: 0.5 ms, approx. Release: 3.5 ms, approx. Operating Frequency: Mechanical: 36,000 ops/hr. Electrical: 1,800 ops/hr at rated load. Environmental Data Temperature Range: -40°C to +70°C. Relative Humidity Range: 35% to 85%. Shock: Functional: 200m/s2 (approx. 10g). Destructive: 1,000m/s2 (approx. 100g). Vibration: 10-55 Hz., .059 in (1.5 mm) double amplitude. Initial Insulation Resistance Between Contact and Coil: 109 ohms or more @ 500VDC. Contact Data @ 23°C Arrangement: Bifurcated 2 Form C (DPDT) contacts. Material: Stationary: Silver, gold clad. Ratings: Max. Switched Current: 2A. Max. Carry Current: 2A. Max. Switched Voltage (at nom. voltage): 125VDC, 125VAC. Max. Switched Power: 60W DC or 62.5VA AC. Min. Switching Load: 10µA, 10mVDC. Rated Load: 500mA at 125VAC. Initial Contact Resistance: 50 milliohms. Expected Mechanical Life: 15,000,000 ops at 36,000 ops/hr. Coil Data @ 23°C Voltage: 3 to 48VDC. Nominal Power: 150mW to 580mW. See Coil Data table for details. Duty Cycle: Continuous. Nominal Current Maximum Resistance Approx. Voltage ±10% Voltage ±10% Power (VDC) (mA) (VDC) (Ohms) (mW) Standard sensitivity (Max. Voltage stated @ 65°C, except 48V @ 60°C) 3 166.7 3.6 18 500 5 100.0 6.0 50 500 6 83.3 7.2 72 500 9 55.6 10.8 162 500 12 41.7 14.4 288 500 24 20.8 28.8 1,152 500 48 12.0 52.8 4,000 580 High sensitivity (Max. Voltage stated @ 70°C) 3 120.7 3.6 25 360 5 72.0 6.0 70 360 6 60.0 7.2 100 360 9 40.0 10.8 225 360 12 30.0 14.4 400 360 24 15.0 28.8 1,600 360 48 7.5 52.8 6,400 360 Ultra high sensitivity (Max. Voltage stated @ 70°C) 3 50.0 4.5 60 150 5 30.0 7.5 167 150 6 25.0 9.0 240 150 9 16.7 13.5 540 150 12 12.5 18.0 960 150 24 8.3 36.0 2,880 200 48 6.25 72.0 7,680 300Ap Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Initial Dielectric Strength Between Open Contacts: 750VAC 50/60 Hz. for 1 minute. Between Coil and Contacts: 1,000VAC 50/60 Hz. for 1 minute. Between Poles: 1,000VAC 50/60 Hz. for 1 minute. Surge Voltage Resistance per FCC 68 (10 / 160 µs): Between Open Contacts: 1,500V. Between Coil and Contacts: 1,500V. Between Poles: 1,500V.
reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. P&B Catalog 1308242 Issued 3-03 www.tycoelectronics.com Technical support: Refer to inside back cover. Outline Dimensions Wiring Diagram (Bottom View) PC Board Layout (Bottom View) 190-22B2UO 190-22C2UO 190-22E2UO
Ordering Information
Typical Part Number ➤ 190 - 2 2 B 2 UO 1. Basic Series: 190 = Miniature PC board relay. 2. Enclosure and Terminals: 2= DIP, 16-pin package, sealed. 3. Contact Arrangement: 2= DPDT (2 form C). 4. Coil Voltage: J = 3VDC A= 6VDC B = 12VDC D = 48VDC E= 5VDC G= 9VDC C = 24VDC 5. Contact Material and Type: 2= Silver, gold clad. Bifurcated crossbar. 6. Coil Sensitivity Our authorized distributors are more likely to stock the following items for immediate delivery. Operational Performance Curves Maximum Switching Capacity Electrical Service Life Ambient Temp. vs. Max. Voltage