100 MHz, 100 MS/s, 14-Bit Digitizer

high-channel-count or mixed-signal test systems. frequency-domain measurements. feature maximizes the use of the entire 14 bits of vertical range. the entire operating temperature range of 0 to 55 °C. acquisitions and streaming to disk.

  • 2 channels simultaneously sampled at 14-bit resolution
  • 100 MS/s real-time and 2.0 GS/s random interleaved sampling
  • 100 MHz bandwidth
  • 50 Ω or 1 MΩ input impedance, software-selectable
  • 200 mV to 20 V input range
  • 75 dBc SFDR and 62 dB SINAD
  • Memory options from 8 to 512 MB per channel
  • Edge, window, hysteresis, video, and digital triggering with 100 ps timestamping Models
  • NI PCI-5122
  • NI PXI-5122
  • NI PXIe-5122 Operating Systems
  • Windows Vista/XP/2000 Recommended Software
  • LabVIEW
  • LabWindows™ /CVI
  • Measurement Studio for Visual Studio Other Compatible Software
  • Visual Basic
  • C/C++
  • .NET Application Software (included)
  • Spectral Measurements Toolkit (32 and 256 MB/channel models only) Driver Software (included)
  • NI-SCOPE NI 5122

Figure 1. Graph of Dynamic Performance (FFT)

record and playback, and scientific applications. settings also apply when the module is used in multiple-record mode. waveform generator/analyzers. Figure 2. Hardware Block Diagram Figure 3. Spectral Measurements Toolkit 3D Spectrogram

These specifications are valid for 0 to 55° C for PXI, and 0 to 45° C for PCI, unless otherwise stated. Acquisition System Bandwidth limit filters

40 MHz antialias

(-6 dB, 6-pole Chebyshev) random interleaved sampling (4 to 256 million samples) Pretrigger and posttrigger data points 2... 0 to 100% of full record length software selectable Maximum number of records for all other memory options

4 V, 10 V

1 MΩ: 200 mV, 400 mV, 1 V, 2 V,

4 V, 10 V, 20 V

1 MΩ: peaks ≤42 V

on 1 MΩ only) AC coupling cutoff Accuracy DC accuracy (0 V offset setting) Passband Flatness (referenced to 50 kHz) Spectral Characteristics (typical) Dynamic performance (50 Ω input impedance with 10 MHz, -1 dBFS input signal, filters on) BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)

Ordering Information

Includes NI 5122 device, NI-SCOPE, and Scope Soft Front Panel. The 32 and 256 MB/channel models also include the NI Spectral Measur ements Toolkit. Accessories Recommended PXI switch Switchable 1/10x probe 9-pin DIN to BNC for AUX I/O connector

Related Products

NI 5421 arbitrary waveform generators NI PXI-5404 clock and frequency generator NI PXI-655x digital waveform generator/analyzers BUY NOW! For complete product specifications, pricing, and accessory information, call 800 813 3693 (U.S.) or go to ni.com/digitizers. Full Scale Input Range 50 Ω and 1 MΩ 200 mV, 400 mV, 1 V, 2 V ±0.65% of input ±1.0 mV (±2.0 mV for PCI) 4 V, 10 V ±0.65% of input ±8.0 mV 20 V ±0.65% of input ±10.0 mV Maximum Data Streaming Rates4 PCI/PXI PXI Express

110 MB/s 400 MB/s

Full Scale Input Range 50 Ω and 1 MΩ Filters off 400 mV, 1 V, 2 V, 5 V,

10 V, 20 V

±0.4 dB DC to 20 MHz ±1 dB 20 to 50 MHz 200 mV ±0.4 dB DC to 20 MHz ±1 dB 20 to 40 MHz Antialias filter on All ranges ±1.2 dB DC to 16 MHz ±1.6 dB 16 to 32 MHz Full Scale Input Range SFDR (dBc) THD (dBc) SNR (dB) SINAD (dB) 200 mV 75 -75 60 60 400 mV 75 -75 62 62

1 V 75 -75 62 62

2 V 75 -75 62 62

4 V 65 -63 – –

10 V 65 -63 – –

SFDR = Spurious-free dynamic range THD = Total harmonic distortion SNR = Signal-to-noise ratio, excluding distortion (antialias filter enabled) SINAD = Signal-to-noise and distortion (antialias filter enabled)

Dynamic performance (1 MΩ input impedance with 10 MHz, -1 dBFS input signal, filters on) Phase noise density (10 MHz input) ... <-100 dBc/Hz at 100 Hz, <-120 dBc/Hz at 1 kHz, <-130 dBc/Hz at 10 kHz Acquisition Modes sampling rate rate (repetitive signals only) Timebase System Internal with decimation by n where 1 ≤n ≤65,535 External PXI Star Trigger), variable with decimation by n where 1 ≤n ≤65,535 PXI backplane 10 MHz increments Trigger System digital, immediate, software PFI <0:1>, PXI Star, Software and SECAM standards

50 MHz increasing to 5% FS at

100 MHz; TRIG: 2.5% up to

100 MHz increasing to 10%

External Trigger Channel (TRIG) Power Environment and IEC-60068-2-2) and 60068-2-2) (meets 60068-2-56) Calibration meets NIST-traceable standards response, triggering, and timing for all input ranges National Instruments or ship to a qualified metrology lab 1Bandwidth on 200 mV range is 80 MHz. 2NI 5122 also supports continuous acquisition. 30 to 100% pretrigger and posttrigger data. 4Rates are for a single NI 5122 device. Dedicated per-slot bandwidth available in PXI Express enables multimodule systems to achieve higher aggregate data rates. Using a 12-drive high-performance RAID system, aggregate data rates up to 600 MB/s to disk are possible. 5Measured on ranges up to 2 V on 50 Ω input with two tones at 10.2 and 11.2 MHz, each at -7 dBFS. 6Includes effects of converter aperture and clock circuitry jitter from 100 Hz to 100 kHz. 7Time-digital-converter disabled. 80 to 45 ° C in PXI-101x and 1000/B chassis. BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) Full Scale Input Range SFDR (dBc) THD (dBc) SNR (dB) SINAD (dB) 200 mV 70 -68 60 59 400 mV 70 -68 62 61

1 V 70 -68 62 61

2 V 70 -68 62 61

4 V 70 -68 62 61

10 V 60 -58 – –

20 V 60 -58 – –

SFDR = Spurious-free dynamic range THD = Total harmonic distortion SNR = Signal-to-noise ratio, excluding distortion (antialias filter enabled) SINAD = Signal-to-noise and distortion (antialias filter enabled) Typical +3.3 VDC +5 VDC +12 VDC -12 VDC Total Power PXI 1.4 A 1.5 A 110 mA 270 mA 16.7 W PCI 1.4 A 2.4 A 110 mA 0 A 17.9 W PXIe 1.6 A 0 A 2.0 A 0A 29.3 W

NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services. Training and Certification NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. We also offer a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training. Professional Services Our Professional Services Team is comprised of NI applications engineers, NI Consulting Services, and a worldwide National Instruments Alliance Partner program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. OEM Support We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. Local Sales and Technical Support In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industry-leading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp. Hardware Services NI Factory Installation Services NI Factory Installation Services (FIS) is the fastest and easiest way to use your PXI or PXI/SCXI combination systems right out of the box. Trained NI technicians install the software and hardware and configure the system to your specifications. NI extends the standard warranty by one year on hardware components (controllers, chassis, modules) purchased with FIS. To use FIS, simply configure your system online with ni.com/pxiadvisor. Calibration Services NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration. Repair and Extended Warranty NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services. © 2007 National Instruments Corporation. All rights reserved. CVI, LabVIEW, Measurement Studio, MITE, National Instruments, National Instruments Alliance Partner, NI, ni.com, R TSI, and SCXI ar e trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Other product and company names listed ar e trademarks or trade names of their r espective companies. A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI. National Instruments • info@ni.com ni.com • 800 813 3693 *351026D-01* 351026D-01 2007-8711-101-D