1839A BELDEN | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 3
Technical content
Product: 1839A DBS Cable, RG6, 18 AWG BCCS, Foil + Braid, Messenger Product Description Series 6, 18 AWG solid .040" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond® II, Al. braid shield (60% coverage), .045" bare copper-covered steel static ground, PVC jacket. Technical Specifications Physical Characteristics (Overall) Conductor AWG Stranding Material Nominal Diameter No. of Coax 18 Solid BCCS - Bare Copper Covered Steel 0.04 in 1 Conductor Count: 1 Insulation Material Nominal Diameter PE - Polyethylene (Foam) 0.18 in Table Notes: Gas Injected Outer Shield Type Layer Material Material Trade Name Coverage [%] Tape 1 Tri-Laminate (Alum+Poly+Alum) Duofoil® 100% Braid 2 Aluminum 60% Outer Jacket Material Nominal Diameter PVC - Polyvinyl Chloride 0.27 x 0.405 in Construction and Dimensions Static Ground: BCCS - Bare Copper Covered Steel Static Ground Diameter: 0.045 in
Electrical Characteristics
Nominal Conductor DCR Nominal Outer Shield DCR Outer Conductor DCR
28 Ohm/1000ft 9 Ohm/1000ft 9 Ohm/1000ft
Nom. Capacitance Conductor to Shield 16.2 pF/ft Inductance Nominal Inductance 0.097 µH/ft Impedance Nominal Characteristic Impedance
75 Ohm
Return Loss (RL) Frequency [MHz] Min. Structural Return Loss (SRL) 950 - 2250 MHz 15 dB 2250 - 3000 MHz 10 dB High Frequency (Nominal/Typical) Frequency [MHz] Nom. Insertion Loss 5 MHz 0.5 dB/100ft 55 MHz 1.4 dB/100ft 211 MHz 2.6 dB/100ft 500 MHz 4.1 dB/100ft 750 MHz 5.1 dB/100ft 862 MHz 5.5 dB/100ft
1000 MHz 6 dB/100ft
1450 MHz 7.8 dB/100ft 1800 MHz 8.6 dB/100ft 2250 MHz 9.8 dB/100ft 3000 MHz 11.3 dB/100ft Delay Nominal Delay Nominal Velocity of Propagation (VP) [%] 1.2 ns/ft 83% High Frequency Frequency [MHz] Max. Insertion Loss (Attenuation) 5 MHz 0.58 dB/100ft 55 MHz 1.6 dB/100ft 211 MHz 3.05 dB/100ft 500 MHz 4.66 dB/100ft 750 MHz 5.65 dB/100ft 862 MHz 6.1 dB/100ft 1000 MHz 6.55 dB/100ft
1450 MHz 8 dB/100ft
1800 MHz 8.8 dB/100ft
2250 MHz 10 dB/100ft
3000 MHz 11.9 dB/100ft Voltage Non-UL Voltage Rating
350 V RMS
Non-UL Temp Rating: 80°C Operating Temperature Range: -40°C To +80°C Mechanical Characteristics Bulk Cable Weight: 41 lbs/1000ft Max. Pull Tension: 160 lbs Min. Bend Radius/Minor Axis: 3 in Standards RG Type: 6 Series Type: 6 Applicable Environmental and Other Programs Environmental Space: Indoor (Not Riser or Plenum) EU Directive 2000/53/EC (ELV): Yes EU Directive 2003/96/EC (BFR): Yes EU Directive 2011/65/EU (RoHS 2): Yes
EU Directive 2012/19/EU (WEEE): Yes EU Directive 2015/863/EU (RoHS 2 amendment): Yes EU Directive Compliance: EU Directive 2003/11/EC (BFR) EU CE Mark: No MII Order #39 (China RoHS): Yes Suitability Suitability - Indoor: Yes Plenum/Non-Plenum Plenum (Y/N): No Related Part Numbers Variants Item # Color Put-Up Type Length UPC 1839A 0101000 Black Reel 1,000 ft 612825124276 Footnote: C - CRATE REEL PUT-UP. History Update and Revision: Revision Number: 0.384 Revision Date: 11-09-2022 © 2024 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.